ICC E3 study materials
ICC E3 study resources

ICC E3 key terms

ICC E3 · Get comfortable with the vocabulary.

approved

Acceptable to the authority having jurisdiction. The term signals that the code official, not the installer, decides whether equipment or a method is permissible, and it may rest on listing, labeling, or field evaluation.

Related: authority having jurisdiction, listed, labeled
authority having jurisdiction (AHJ)

The organization, office, or individual responsible for enforcing code requirements or approving equipment, materials, installations, or procedures. Inspectors, fire marshals, and building officials commonly act as the AHJ for electrical work.

Related: approved, plan review, permit
listed

Equipment, materials, or services included in a published list by an organization concerned with product evaluation that maintains periodic inspection of production and states the item meets a designated standard.

Related: labeled, approved, NRTL
labeled

Equipment or materials to which a label, symbol, or other identifying mark of a qualified testing organization has been attached, indicating compliance with appropriate standards or performance in a specified manner.

Related: listed, NRTL, approved
NRTL

Nationally Recognized Testing Laboratory: a private organization recognized by OSHA to test and certify products to safety standards. UL, ETL, and CSA are common examples whose marks support the code's listing and labeling requirements.

Related: listed, labeled
plan review

The pre-construction examination of drawings, specifications, and calculations by the code official to verify compliance before a permit is issued. Reviewers check load calculations, one-line diagrams, device ratings, and grounding details.

Related: permit, approved, as-built drawings
permit

Official authorization to begin work covered by the code. Electrical permits typically require submitted plans and fee payment, and work must match the approved documents or be revised through the jurisdiction.

Related: plan review, inspection, certificate of occupancy
as-built drawings

Drawings revised to show the installation as actually constructed, including field changes from the permitted design. Reviewers and inspectors use them to confirm that deviations were approved and documented.

Related: plan review, permit
certificate of occupancy

A document issued by the building official confirming a structure may be occupied for its intended use. Electrical final inspection and approval are typically prerequisites before it is granted.

Related: permit, inspection
inspection

On-site verification by the AHJ that installed work complies with the code and approved plans. Common stages include underground, rough-in, and final inspections, and cover work must be approved before concealment.

Related: permit, authority having jurisdiction
ampacity

The maximum current, in amperes, a conductor can carry continuously under stated conditions of use without exceeding its temperature rating. It depends on conductor size, insulation, ambient temperature, and number of current-carrying conductors.

Related: ambient temperature correction, adjustment factor, continuous load
continuous load

A load expected to operate at maximum current for three hours or more. Conductors and overcurrent devices serving continuous loads must be sized at 125 percent of the load unless the code states otherwise.

Related: noncontinuous load, ampacity, overcurrent device
noncontinuous load

A load expected to operate at maximum current for less than three hours. It is added at its full calculated value, without the 125 percent multiplier applied to continuous loads.

Related: continuous load, demand factor
demand factor

The ratio of the maximum demand on a system to the total connected load. Applying demand factors permits smaller feeders and services because not all loads operate simultaneously at full value.

Related: connected load, load calculation, feeder
connected load

The sum of the rated capacities of all equipment and devices supplied by a system, before any demand factors are applied. It represents the worst-case total if everything ran at once.

Related: demand factor, load calculation
load calculation

A structured method of summing general lighting, receptacle, appliance, and motor loads, then applying demand factors, to determine the minimum feeder, service, and panelboard ratings for a building.

Related: demand factor, service, feeder
service

The conductors and equipment that deliver power from the serving utility to the wiring system of the premises. Service-entrance conductors, service equipment, and the service point define its boundaries.

Related: feeder, service disconnect, service point
feeder

All circuit conductors between the service equipment, source of a separately derived system, or other supply source and the final branch-circuit overcurrent device. Feeders supply panelboards rather than individual outlets.

Related: branch circuit, service, panelboard
branch circuit

The circuit conductors between the final overcurrent device protecting the circuit and the outlet or outlets it serves. Branch circuits supply the actual utilization equipment and receptacles.

Related: feeder, multi-wire branch circuit, overcurrent device
multi-wire branch circuit

A branch circuit with two or more ungrounded conductors having a voltage between them and a grounded conductor with equal voltage to each ungrounded conductor. It requires a common trip or handle-tied breakers and grouped conductors.

Related: branch circuit, grounded conductor, neutral
overcurrent device

Any device, such as a fuse or circuit breaker, that automatically opens a circuit when current exceeds a set value. It protects conductors and equipment from overloads and short circuits.

Related: ampacity, ground-fault protection, breaker
grounded conductor

A system or circuit conductor intentionally connected to earth, commonly the neutral. It carries return current under normal operation and is bonded to grounding at the service.

Related: neutral, grounding electrode conductor, multi-wire branch circuit
equipment grounding conductor

The conductive path installed to connect normally non-current-carrying metal parts of equipment together and to the system grounded conductor or grounding electrode conductor. It carries fault current to trip the overcurrent device.

Related: bonding, grounding electrode conductor, ground fault
grounding electrode conductor

The conductor that connects the grounding electrode system to the grounded conductor or equipment grounding conductor at the service or source. It provides the earth connection for the electrical system.

Related: grounding electrode, grounded conductor, bonding jumper
grounding electrode

A conductive object such as a ground rod, metal water pipe, or concrete-encased electrode that is in direct contact with the earth and establishes a connection to ground.

Related: grounding electrode conductor, grounding electrode system
grounding electrode system

The set of grounding electrodes bonded together to form a single grounding connection. Where multiple electrodes are present, the code generally requires them to be bonded into one system.

Related: grounding electrode, bonding jumper, grounding electrode conductor
bonding

The permanent joining of metallic parts to form an electrically conductive path that ensures electrical continuity and the capacity to conduct safely any current likely to be imposed.

Related: bonding jumper, equipment grounding conductor, ground fault
bonding jumper

A reliable conductor that ensures the required electrical conductivity between metal parts required to be electrically connected. It may connect electrodes, equipment, or enclosures within the grounding system.

Related: bonding, grounding electrode system
ground fault

An unintentional connection between an ungrounded conductor and normally non-current-carrying metal parts, raceways, or earth. It is cleared by the equipment grounding path and overcurrent device.

Related: equipment grounding conductor, ground-fault circuit interrupter, ground-fault protection
ground-fault circuit interrupter (GFCI)

A device that de-energizes a circuit within a set time when current to ground exceeds a threshold below that needed to protect conductors. It protects people from shock in wet or damp locations.

Related: ground fault, arc-fault circuit interrupter, ground-fault protection
arc-fault circuit interrupter (AFCI)

A device that detects and interrupts dangerous electrical arcs, such as from damaged or loose conductors, before they ignite surrounding material. It is commonly required on branch circuits serving dwelling unit living areas.

Related: ground-fault circuit interrupter, branch circuit
ground-fault protection of equipment (GFPE)

A system that disconnects a circuit when fault current to ground reaches a level that could damage equipment, typically set higher than GFCI thresholds. It is often used on large services and feeders.

Related: ground fault, ground-fault circuit interrupter, service
neutral

The grounded conductor of a system that carries unbalanced current from line-to-neutral loads. It is bonded to ground only at the service or separately derived system, not downstream.

Related: grounded conductor, multi-wire branch circuit
working space

The clear, unobstructed area in front of electrical equipment required for safe examination, adjustment, servicing, and maintenance. Depth depends on voltage and whether live parts are exposed on the opposite side.

Related: dedicated equipment space, panelboard, clearance
dedicated equipment space

Space reserved solely for electrical equipment, extending from the floor to a height above the equipment and from the front to a distance behind it. Pipes, ducts, and leaks are generally prohibited there.

Related: working space, panelboard
panelboard

A single panel containing buses and automatic overcurrent devices, with or without switches, designed to be placed in a cabinet or cutout box. It distributes power to branch circuits or feeders.

Related: feeder, branch circuit, working space
service disconnect

The main switch or breaker that disconnects all service-entrance conductors from the building wiring. It must be clearly marked, readily accessible, and rated for the calculated service load.

Related: service, overcurrent device
special occupancy

A building or space type with unusual hazards or conditions, such as health care facilities, places of assembly, hazardous locations, or marinas, that triggers additional or modified code requirements.

Related: hazardous location, classified location
hazardous (classified) location

An area where fire or explosion hazards may exist because of flammable gases, vapors, dusts, fibers, or flyings. Equipment and wiring methods must be specifically approved for the class, division or zone, and group.

Related: classified location, special occupancy, explosionproof
explosionproof equipment

Enclosures designed to contain an internal explosion and prevent ignition of surrounding flammable atmospheres, while operating at temperatures below ignition thresholds. It is used in certain classified locations.

Related: hazardous (classified) location, classified location
classified location

A location designated by class, division or zone, and group based on the type and likelihood of flammable materials present. The classification dictates permissible wiring methods and equipment.

Related: hazardous (classified) location, explosionproof equipment
health care facility

A building or portion used for medical, dental, or psychiatric care where patients are examined or treated. It imposes requirements for redundant grounding, isolated power, and patient care area receptacles.

Related: special occupancy, equipment grounding conductor
temporary wiring

Wiring installed for a limited time, such as at construction sites, carnivals, or holiday displays. It must be removed when the purpose ends and is subject to specific rules for support, protection, and GFCI use.

Related: special occupancy, ground-fault circuit interrupter