ICC FM · Put your knowledge to work in context.

The ICC Fire Marshal certification is a professional credential offered through the International Code Council's credentialing program, one of the certification paths ICC lists for building safety professionals seeking to advance their careers. It is aimed at fire prevention officers, fire inspectors, deputy fire marshals, and code officials who review construction projects for fire safety, investigate how fires start, and run community risk-reduction and preparedness programs. The ICC FM case studies are 5 cases and about 3,398 words.

1

Battery Fire Cluster in a Dense Rental Corridor

A fire marshal in a city of 180,000 reviews 12 months of incident data and finds 19 fires involving lithium-ion batteries in a 0.6-square-mile rental corridor; 14 were e-bike or scooter batteries charged in bedrooms or hallways, 3 injuries, 1 fatality. The corridor has 4,200 renter-occupied units, many in 1960s wood-frame buildings with one stair, no sprinklers, and 40% of tenants speak a language other than English.

726 words, about 4 min
2

Tiny Home Village With No Hydrant Nearby

A nonprofit proposes a 20-unit tiny-home village for 40 formerly homeless residents on 1.5 acres. The site has an existing 6-inch dead-end water main; the nearest public hydrant is 650 ft from the site entrance; access is a 20-ft-wide private drive 300 ft long with no turnaround; units are 120 sq ft each, spaced 10 ft apart; the community building is 1,200 sq ft with a commercial kitchen and a 40-person assembly room.

711 words, about 4 min
3

Living Room Fire With Arcing at a Receptacle

At 02:10, a neighbor reports fire in the living room of a 1,800 sq ft two-story house. Fire is confined to the living room; a 68-year-old occupant is found near the front door and pronounced dead.

656 words, about 3 min
4

WUI Evacuation With One Road and Low Compliance

A hillside community of 120 single-family homes has one two-lane road in and out, a 30% slope, and a 20-ft setback to continuous chaparral on two sides. The local fire agency uses a 'Ready, Set, Go' message.

653 words, about 3 min
5

WUI Addition With a Wood Shake Roof

A homeowner in a high fire hazard severity zone proposes a 1,200 sq ft addition to a 2,000 sq ft single-family home. The existing roof is 25-year-old wood shake; the addition will have wood siding, an unenclosed deck, and standard soffit vents.

652 words, about 3 min