ICC FM study materials
ICC FM study resources

ICC FM cheat sheet

ICC FM · Keep the key ideas within reach.

Quick reference

Fire Prevention and Fire Safety Education

  • Fire tetrahedron: fuel, oxygen, heat, and the uninhibited chemical chain reaction; removing any one leg extinguishes combustion. Legacy triangle omits the chain reaction.

  • Four fire classes drive agent selection: A (ordinary combustibles, water), B (flammable liquids, smothering/foam), C (energized electrical, nonconductive agent), D (combustible metals, dry powder), plus K for cooking oils in commercial kitchens.

  • Flammable/combustible liquid thresholds (IFC 2021): Class IA flash point <73 F and boiling point <100 F; Class IB flash point <73 F and boiling point >=100 F; Class IC flash point >=73 F and <100 F; Class II >=100 F and <140 F; Class IIIA >=140 F and <200 F; Class IIIB >=200 F.

  • Flammable gas threshold: a gas is flammable when a mixture with air is ignitable at <=1 atm and 68 F (20 C) in any proportion, or has a flammable range with air at 68 F regardless of lower limit.

  • Ignition temperature is the minimum temperature at which a material ignites without an external pilot; it differs from flash point (vapor ignition with pilot) and fire point (sustained burning).

  • Education program effectiveness is measured against behavior and outcome metrics (alarm presence, escape-plan practice, incident rates), not attendance counts alone.

  • Smoke alarms: ionization responds faster to flaming fires; photoelectric responds faster to smoldering fires. Both technologies are recommended for maximum warning.

  • Exit sign and path marking education: occupants have seconds to minutes; teaching two-ways-out, door-closing, and staying low targets the survivable interval.

  • Public education materials must match reading level and language of the served population; NFPA and USFA provide free reproducible materials for local distribution.

Quick reference

Plan Review and Construction Project Fire Safety Considerations

  • Occupant load factor divides floor area by a use-specific factor (e.g., assembly unconcentrated 15 sq ft/person; business 100 sq ft/person; educational classrooms 20 sq ft/person) to size exits.

  • Egress capacity: level components 0.2 in per occupant, stairways 0.3 in per occupant; required egress width is the larger of capacity-based and minimum-width requirements.

  • Two exits are required where occupant load exceeds the threshold for the use group (commonly 49 for assembly/mercantile/educational) or where travel distance exceeds limits.

  • Common path and travel distance limits are use-group specific; dead-end corridors are generally limited to 20 ft in nonsprinklered and 50 ft in sprinklered buildings.

  • Fire-resistance-rated assemblies are tested to ASTM E119 or UL 263; opening protectives (fire doors, fire windows, dampers) carry their own rating and labeling requirements.

  • Sprinkler design is governed by NFPA 13 (and 13R/13D for residential); plan review verifies hazard classification, density/area curves, and water supply adequacy.

  • Fire flow demand is estimated from the needed fire flow method (ISO) or local code tables using construction class, occupancy, and exposure; verify hydrant spacing and residual pressure.

  • High-piled storage (over 12 ft) triggers NFPA 13 Chapter 20+ design criteria; rack configuration, commodity class, and flue spaces change required density.

  • Construction-phase fire safety plans address hot work permits, temporary heating, site security, and standpipe/sprinkler availability during phased occupancy.

Quick reference

Fire Ignition and Origin Analysis

  • Fire pattern analysis: V-patterns point to the origin at the apex; charring depth and alligatoring indicate duration and intensity, not necessarily direction.

  • Heat transfer modes are conduction (through solids), convection (through fluids/gases), and radiation (line-of-sight, inverse-square falloff).

  • Flashover occurs when upper-layer temperature reaches roughly 1,100-1,200 F and heat flux at floor level exceeds about 20 kW/m2; post-flashover patterns differ from pre-flashover.

  • Arc mapping locates points where energized conductors arced; the arc site is not automatically the fire origin, only a location of electrical activity.

  • Spoliation and evidence chain: origin determination precedes cause determination; cause classifications include accidental, incendiary, natural, and undetermined.

  • Ignitable liquid detection uses headspace sampling, solid-phase microextraction, and GC-MS; absence of residue does not prove absence of liquid.

  • Burn indicators: calcination of gypsum, spalling of concrete, and melting of metals give temperature ranges (e.g., copper melts near 1,981 F) useful for timeline reconstruction.

  • Competing hypotheses must be tested against all physical evidence; NFPA 921 methodology requires eliminating alternatives before assigning cause.

Quick reference

Wildland-Urban Interface (WUI) Fire Risk Reduction and Emergency Preparedness

  • Home ignition zone is divided into zones: 0-5 ft noncombustible (Zone 0), 5-30 ft lean/clean/green (Zone 1), and 30-100 ft reduced fuel (Zone 2); ember ignition is the dominant home-loss mechanism.

  • Structure ignition pathways: radiant heat, direct flame contact, and firebrand/ember accumulation in gutters, vents, and decks.

  • Defensible space is measured from the structure; slope increases required distance because upslope fire spreads faster and radiates more intensely.

  • WUI risk ratings combine fuel hazard, slope, aspect, and structural ignitability; many jurisdictions use a parcel-level score to prioritize mitigation.

  • Firewise USA recognition requires a community wildfire protection plan, an annual renewal, and documented volunteer hours and mitigation actions.

  • Evacuation planning uses trigger points tied to fire behavior, and 'Ready, Set, Go!' phases: Ready (prepare), Set (monitor and be ready to leave), Go (evacuate immediately).

  • Home hardening elements: Class A roof, noncombustible 6-inch fascia and soffits, ember-resistant vents (1/8-inch mesh or listed), tempered dual-pane windows, and noncombustible decking.

  • Prescribed fire and mechanical fuel reduction are the primary landscape treatments; treatments must be maintained because fuel regrows within years.

Quick reference

Additional Fire Prevention and Education Reference

  • Fire extinguisher PASS: Pull the pin, Aim at the base, Squeeze the handle, Sweep side to side; only trained occupants should attempt suppression on small, contained fires.

  • Home escape planning: two ways out of every room, a meeting place, and a practiced drill at least twice a year; close doors while escaping to limit fire spread.

  • Cooking is a leading cause of home fires and home fire injuries; unattended cooking and combustible items near the cooktop are primary factors.

  • Heating equipment is a leading cause of home fire deaths in winter months; keep three feet of clearance around space heaters and never use ovens for heating.

  • Electrical education targets overloaded circuits, extension cords as permanent wiring, and counterfeit or damaged cords; AFCI/GFCI devices address specific failure modes.

  • Juvenile firesetter intervention programs use screening tools and family education rather than punishment alone; early intervention reduces recidivism.

  • Carbon monoxide is produced by incomplete combustion; detectors should be placed near sleeping areas and on each level, not directly above fuel-burning appliances.

Quick reference

Additional Plan Review Reference

  • Means of egress components: exit access (travel to exit), exit (protected path), exit discharge (to public way); each has distinct requirements.

  • Exit access travel distance is measured along the path of travel, not straight-line distance, and is measured to the nearest exit.

  • Fire alarm system plan review per NFPA 72 covers device spacing, notification appliance audibility (15 dBA above ambient), and survivability for high-rise.

  • Standpipe and hose system classes: Class I (2.5-inch for fire department), Class II (1.5-inch for occupant use), Class III (both).

  • Smoke control systems in atria and high-rise buildings use either pressurization or exhaust; design must demonstrate tenability during egress.

  • Type of construction (I-V) determines allowable height and area; Type I is most fire resistive, Type V least; sprinkler increases allowable area.

  • Fire department access roads require minimum width (commonly 20 ft), turning radius, and aerial apparatus access near building faces.

Quick reference

Additional Origin and Cause Reference

  • Fire cause determination uses the scientific method: identify the problem, collect data, develop hypotheses, test hypotheses, select the final hypothesis.

  • Negative corpus (declaring a cause without evidence) is discredited; undetermined is a valid and often correct classification.

  • Electrical fire indicators include beading of copper, melted insulation, and arc tracking; these must be distinguished from fire-caused damage.

  • Appliance and equipment failure analysis considers manufacturing defects, misuse, and lack of maintenance; recall databases can identify patterns.

  • Smoldering versus flaming combustion produces different residue and char patterns; smoldering often occurs in upholstery and insulation.

  • Photography and documentation should capture overall, medium, and close-up views before disturbance; sketches supplement photos with measurements.

  • Fire death investigation integrates toxicology (CO, cyanide), pathology, and scene analysis; COHb and cyanide levels inform survivability analysis.

Quick reference

Additional WUI Preparedness Reference

  • Ember cast can travel over a mile ahead of the flame front; most homes ignite from embers, not the main fire front.

  • Community Wildfire Protection Plan (CWPP) is a collaborative document identifying values at risk, fuel treatments, and evacuation routes.

  • Structural triage during WUI incidents categorizes homes as defensible, non-defensible, or prep-and-hold based on access, fuel, and construction.

  • Water supply planning for WUI includes hydrant adequacy, draft sites, and tenders; many WUI areas lack municipal water.

  • Post-fire assessment documents structure survival and the factors that contributed, informing future code and education efforts.

  • WUI codes (e.g., IWUIC) regulate roofing, exterior walls, decks, and vegetation; adoption varies by jurisdiction.

  • Public alerting uses WEA, opt-in notification systems, and door-to-door notification; redundancy is essential because power and cell service may fail.

Quick reference

Fire Safety Education Program Design

  • Needs assessment identifies the target audience, the specific fire problem, and existing resources before program design.

  • Logic models link inputs, activities, outputs, and outcomes; they make program evaluation and funding justification explicit.

  • Partnerships with schools, faith organizations, and healthcare providers extend reach beyond fire department channels.

  • Evaluation designs include pre/post surveys, observation of behavior, and long-term incident data; self-report alone is weak evidence.

  • Cultural competence requires adapting materials to language, literacy, and trusted messengers within the community.

  • Programs targeting older adults address cooking, smoking, and heating hazards; mobility and sensory limitations affect response time.

  • Youth programs (e.g., Learn Not to Burn) integrate fire safety into school curricula with age-appropriate content.

Quick reference

Plan Review Process and Documentation

  • Submittal review checks completeness first: plans, calculations, product data, and hydraulic calculations must be present before technical review begins.

  • Plan review comments should cite the specific code section, describe the deficiency, and state the required correction.

  • Deferred submittals (fire alarm, sprinkler, smoke control) must be tracked and reviewed before occupancy.

  • Field inspection verifies that construction matches approved plans; deviations require revised plans and re-review.

  • Certificate of occupancy is withheld until all fire protection systems pass acceptance testing and are documented.

  • Acceptance testing references: NFPA 13 (sprinkler), NFPA 72 (alarm), NFPA 14 (standpipe), NFPA 20 (fire pump).

  • Record retention: approved plans and inspection records should be retained for the life of the building or per jurisdiction policy.

Quick reference

Fire Scene Safety and Evidence Handling

  • Scene safety assessment precedes entry: structural stability, electrical hazards, and hazardous materials must be evaluated.

  • Evidence is documented in place, photographed, and collected with chain-of-custody forms; packaging must prevent cross-contamination.

  • Debris sampling for ignitable liquids uses clean metal cans or approved containers; comparison samples from unaffected areas are essential.

  • Reconstruction may use scale models, computer fire modeling, and full-scale testing to test hypotheses.

  • Witness interviews should be conducted separately and documented with time, location, and interviewer identity.

  • Insurance and legal considerations: reports may be discoverable; accuracy and objectivity are paramount.

  • Laboratory analysis results must be interpreted in context; detection of a compound does not establish its role in ignition.

Quick reference

WUI Mitigation and Response Operations

  • Fuel treatment types: prescribed burning, mechanical thinning, grazing, and herbicide; each has cost, timing, and maintenance considerations.

  • Shaded fuel breaks reduce fire intensity and provide access for suppression while retaining canopy.

  • Structure protection involves pre-treatment (gel, foam), removal of combustibles, and closing windows and vents.

  • Evacuation timing depends on fire behavior, road capacity, and population; late evacuation is a leading cause of WUI fatalities.

  • Shelter-in-place is a last resort when evacuation is not possible; it requires a structure with adequate fire resistance and a safe room.

  • Post-fire flooding and debris flow are secondary hazards; burned watersheds require erosion control and monitoring.

  • Mutual aid agreements and pre-positioning of resources improve response in WUI incidents.

Quick reference

Fire Prevention Code and Enforcement Education

  • Fire code inspections verify maintenance of fire protection systems, housekeeping, and means of egress.

  • Occupancy-specific requirements: assembly (crowd management), mercantile (exit access), residential (smoke alarms).

  • Fire prevention education for businesses includes employee training, evacuation drills, and hot work permits.

  • Public assembly permits may require crowd managers at a ratio (commonly 1 per 250 occupants).

  • Open burning regulations vary by jurisdiction and require permits and setback distances.

  • Fireworks and pyrotechnics require permits, storage requirements, and operator certification.

  • Code adoption cycles: model codes update every three years; jurisdictions adopt with amendments.

Quick reference

Fire Protection System Design Review

  • Sprinkler system types: wet, dry, pre-action, deluge; selection depends on freeze risk and response requirements.

  • Hydraulic calculations demonstrate that the system can deliver the required density at the most remote area.

  • Fire pump sizing considers churn, rated flow, and overload; acceptance testing verifies performance.

  • Standpipe systems require pressure regulation and hose valve accessibility.

  • Fire alarm zoning and addressable systems improve response and troubleshooting.

  • Smoke detection spacing depends on ceiling height and configuration; beam detectors for large spaces.

  • Mass notification systems integrate with fire alarm for emergency communication.

Quick reference

Fire Dynamics for Origin Analysis

  • Compartment fire stages: incipient, growth, fully developed, decay; each produces distinct patterns.

  • Ventilation-limited fires produce incomplete combustion and smoke staining; ventilation changes can cause backdraft or flashover.

  • Backdraft indicators: pressurized smoke, smoke-stained windows, and inward air movement when opened.

  • Fire plume and ceiling jet behavior influence detector activation and sprinkler response.

  • Thermal degradation of materials produces distinct residues used in analysis.

  • Computer fire models (e.g., FDS) can test hypotheses but require validation against physical evidence.

  • Fire death investigation integrates toxicology and scene analysis.

Quick reference

WUI Risk Assessment Tools

  • Wildfire hazard assessments use fuel models, slope, aspect, and weather to estimate fire behavior.

  • Home Ignition Zone assessment evaluates structural ignitability and surrounding fuels.

  • Community risk reduction integrates education, engineering, and enforcement.

  • GIS mapping identifies high-risk parcels and prioritizes mitigation.

  • Fire behavior models (e.g., BehavePlus) predict spread rate and intensity.

  • Weather monitoring and red flag warnings trigger preparedness actions.

  • Post-fire assessments inform future risk reduction.

Quick reference

Fire Safety Education Delivery

  • Messaging should be actionable and specific, not generic.

  • Use multiple channels: schools, media, social media, and community events.

  • Evaluate reach and behavior change.

  • Adapt to audience literacy and language.

  • Partner with trusted community messengers.

  • Use data to target high-risk populations.

  • Document program activities for funding.

Quick reference

Construction Fire Safety

  • Hot work permits require fire watch and area clearance.

  • Temporary heating devices require clearance and ventilation.

  • Site security prevents arson.

  • Standpipes should be available during construction.

  • Phased occupancy requires separation and protection.

  • Fire lanes must remain accessible.

  • Construction debris must be managed.

Quick reference

Origin and Cause Documentation

  • Document overall, medium, and close-up photos.

  • Use sketches with measurements.

  • Maintain chain of custody.

  • Interview witnesses separately.

  • Test hypotheses against evidence.

  • Classify cause: accidental, incendiary, natural, undetermined.

  • Retain records per policy.

Quick reference

WUI Evacuation and Public Information

  • Use trigger points for evacuation decisions.

  • Provide clear, timely public information.

  • Coordinate with law enforcement and emergency management.

  • Plan for vulnerable populations.

  • Use redundant alerting methods.

  • Conduct public education before fire season.

  • Evaluate evacuation after incidents.

Quick reference

Fire Safety Education Evaluation

  • Define measurable objectives.

  • Use pre/post surveys and observation.

  • Track long-term incident data.

  • Compare to baseline.

  • Report results to stakeholders.

  • Adjust program based on findings.

  • Document for funding.

Quick reference

Plan Review Coordination

  • Coordinate with other agencies.

  • Track deferred submittals.

  • Verify acceptance testing.

  • Document inspections.

  • Issue certificates of occupancy.

  • Retain records.

  • Communicate with applicants.

Quick reference

Fire Investigation Methodology

  • Use the scientific method.

  • Collect data systematically.

  • Develop and test hypotheses.

  • Eliminate alternatives.

  • Document all findings.

  • Classify cause.

  • Report objectively.

Quick reference

WUI Community Preparedness

  • Develop a CWPP.

  • Conduct community education.

  • Implement fuel treatments.

  • Harden homes.

  • Plan evacuation.

  • Coordinate response.

  • Evaluate and update plans.