32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Fire tetrahedron
Model of combustion with four components: fuel, oxygen, heat, and chemical chain reaction. Removing any component stops the fire.
Flash point
Minimum temperature at which a liquid gives off enough vapor to ignite when exposed to an ignition source under specified test conditions.
Ignition temperature
Minimum temperature at which a material will ignite and sustain combustion without an external ignition source.
Class K fire
Fire involving cooking oils and fats in commercial cooking equipment; requires wet chemical extinguishing agents.
PASS technique
Extinguisher operation: Pull the pin, Aim at the base of the fire, Squeeze the handle, Sweep side to side.
Occupant load factor
Floor area per occupant used to calculate occupant load; varies by use group and occupancy classification.
Means of egress components
Exit access, exit, and exit discharge; each has distinct code requirements for capacity, protection, and travel distance.
Travel distance
Measured along the path of travel from the most remote point to the nearest exit; limits vary by use group and sprinkler status.
Fire-resistance rating
Period of time an assembly maintains its fire separation function under standardized test conditions (ASTM E119 or UL 263).
NFPA 13
Standard for the installation of sprinkler systems; governs design, density, and acceptance testing.
High-piled storage
Storage over 12 feet in height; triggers specific sprinkler design criteria based on commodity class and rack configuration.
Fire flow
Rate of water supply needed for firefighting, estimated from construction, occupancy, and exposure factors.
V-pattern
Char pattern forming a V shape on a vertical surface, with the apex indicating the origin of the fire.
Flashover
Transition to full-room involvement when upper-layer temperatures reach roughly 1,100-1,200 F and heat flux at floor level exceeds about 20 kW/m2.
Arc mapping
Technique locating points where energized conductors arced; identifies electrical activity locations, not necessarily the fire origin.
Negative corpus
Declaring a fire cause without supporting evidence; discredited methodology. Undetermined is a valid classification.
Chain of custody
Documented record of evidence possession and transfer, ensuring integrity from collection through analysis.
GC-MS
Gas chromatography-mass spectrometry; laboratory method for detecting ignitable liquid residues in fire debris samples.
Home ignition zone
Area around a structure divided into zones (0-5 ft, 5-30 ft, 30-100 ft) with escalating fuel treatment requirements.
Ember cast
Firebrands carried by wind ahead of the flame front; a dominant mechanism of home ignition in WUI fires.
Defensible space
Fuel-modified area around a structure that reduces radiant heat and provides safe access for firefighters.
Firewise USA
Recognition program requiring a community wildfire protection plan, annual renewal, and documented mitigation actions.
Ready, Set, Go!
Evacuation preparedness framework: Ready (prepare), Set (monitor), Go (evacuate immediately when notified).
CWPP
Community Wildfire Protection Plan; collaborative document identifying values at risk, fuel treatments, and evacuation routes.
Structure triage
WUI incident categorization of homes as defensible, non-defensible, or prep-and-hold based on access, fuel, and construction.
Class A roof
Roof assembly with the highest fire resistance rating, effective against firebrand ignition.
Smoke alarm types
Ionization alarms respond faster to flaming fires; photoelectric alarms respond faster to smoldering fires. Both are recommended.
Two ways out
Escape planning principle requiring two exits from every room and a practiced meeting place.
Hot work permit
Authorization for welding, cutting, or grinding, requiring area clearance, fire watch, and post-work monitoring.
Standpipe classes
Class I (2.5-inch for fire department), Class II (1.5-inch for occupants), Class III (both).
Backdraft
Rapid combustion when oxygen enters a ventilation-limited compartment with accumulated combustible gases.
Prescribed fire
Planned, controlled burning to reduce fuel loads and restore ecosystem health; requires permits and weather windows.