ICC B1 study materials
ICC B1 study resources

ICC B1 cheat sheet

ICC B1 · Keep the key ideas within reach.

Quick reference

Code Administration and Inspection Process

  • A permit is required before construction, alteration, repair, or change of occupancy unless the code specifically exempts the work.

  • Required inspections include foundation, framing, and final; concealed work must be inspected and approved before it is covered.

  • Approved construction documents and the permit must be available on the job site for the inspector.

  • Work must not proceed past a required inspection until that inspection has been approved.

  • A stop-work order may be issued for unsafe work or for work that does not conform to approved plans.

  • Materials and appliances must be approved and installed per manufacturer instructions; alternatives require approval.

  • Corrections listed on an inspection report must be completed and reinspected.

  • A certificate of occupancy is required before a new building is occupied.

Quick reference

Building Planning and Light/Ventilation Requirements

  • Habitable rooms must have at least 70 square feet of floor area and no horizontal dimension less than 7 feet.

  • Ceiling height is at least 7 feet in habitable rooms and 6 feet 8 inches in bathrooms, toilet rooms, and corridors.

  • Natural light requires glazing area at least 8 percent of the floor area; operable ventilation requires at least 4 percent.

  • Emergency escape openings must be at least 5.7 square feet, 20 inches wide, 24 inches high, and have a sill no more than 44 inches above the floor.

  • Stairways must be at least 36 inches wide with 6 feet 8 inches of headroom, risers no more than 7.75 inches, and treads at least 10 inches.

  • Handrails are 34 to 38 inches above the stair nosing; guards are at least 36 inches high with openings less than 4 inches.

  • Landings are required at the top and bottom of stairs and must be at least 36 inches long and as wide as the stairway.

  • Smoke alarms are required in sleeping rooms and adjacent areas; carbon monoxide alarms are required where the code specifies.

Quick reference

Footings and Foundations

  • Footings must be at least 12 inches wide and 6 inches thick unless engineered otherwise.

  • Footing bottoms must extend below the frost line and bear on undisturbed soil or engineered fill.

  • Anchor bolts must be at least 1/2 inch diameter, embedded 7 inches, spaced no more than 6 feet, and within 12 inches of plate ends.

  • Sill plates in contact with concrete or masonry must be decay-resistant or treated wood.

  • Foundation walls must be sized for soil pressure and height, with reinforcement as shown on approved plans.

  • Foundation drainage must divert water away from footings; footing drains and gravel are installed where required.

  • Backfill only after the foundation inspection and after required waterproofing or dampproofing is complete.

  • Pier and column footings must be sized for the load and supported on stable soil.

Quick reference

Floor Construction

  • Floor joists must be sized per the span tables and bear at least 1.5 inches on wood supports and 3 inches on masonry or concrete.

  • Notches and holes in sawn joists are limited; holes must not exceed one-third of the joist depth.

  • Bridging or blocking is required where span tables or manufacturer instructions require it.

  • Subfloor panels must be rated for the joist spacing and fastened per the scheduled nailing.

  • Floor design live load is commonly 40 psf for habitable areas and 30 psf for sleeping rooms.

  • Joists must not be cut, notched, or drilled in a way that violates the span table or an approved engineered design.

  • Draftstopping is required in concealed floor/ceiling spaces at the locations and intervals specified by code.

  • Engineered floor members must be installed per the manufacturer's published instructions.

Quick reference

Wall Construction, Wall Coverings, and Exterior Finishes

  • Exterior wall stud size and spacing must comply with the tables; 2x4 at 16 inches and 2x6 at 24 inches are common.

  • Top plates must be doubled and lapped at corners and intersections; bottom plates must be anchored.

  • Headers must be sized for the opening span and supported by king and jack studs.

  • Braced wall lines must use approved bracing methods and provide the required bracing length.

  • Fireblocking is required at concealed spaces, including between floor and wall cavities and at wall intersections.

  • Gypsum wallboard must be of the required thickness and fastened at the scheduled spacing.

  • A weather-resistive barrier is required behind exterior wall coverings and must be lapped and integrated with flashing.

  • Exterior siding must maintain clearance above grade and from roofs, and openings must be flashed.

  • Fasteners for exterior finishes must be corrosion-resistant.

Quick reference

Roof and Ceiling Construction

  • Ceiling joists and rafters must be sized per the span tables and connected to resist outward thrust.

  • Rafter ties are required in the lower third of the attic unless a ridge beam or engineered design is used.

  • Collar ties, where required, are installed in the upper third of the rafter span.

  • Attic access openings must be at least 22 by 30 inches with at least 30 inches of headroom.

  • Attic ventilation must be at least 1/150 of the attic area, or 1/300 where a vapor retarder is installed.

  • Roof slope and ceiling height must provide required clearances and drainage.

  • Ceiling joists must bear and be fastened per the schedule, with lateral ties at walls.

  • Fireblocking is required at concealed roof/ceiling spaces as specified by code.

Quick reference

Roof Coverings

  • Roof coverings require a minimum slope; asphalt shingles generally require at least 2:12.

  • Slopes from 2:12 to 4:12 require double underlayment for asphalt shingles.

  • Underlayment must be installed over the roof deck before the roof covering.

  • An ice barrier is required at eaves in areas subject to ice damming.

  • Flashing is required at valleys, sidewalls, eaves, ridges, and penetrations.

  • Drip edge is required at eave and gable edges.

  • Fasteners must be corrosion-resistant and penetrate the sheathing as required.

  • Roof coverings must be listed and installed per manufacturer instructions for the roof slope.

Quick reference

Chimneys and Fireplaces

  • Chimneys must extend at least 3 feet above the roof and 2 feet above anything within 10 feet.

  • Masonry chimneys require at least 2 inches of clearance from combustible materials.

  • Flues must be lined and sized for the appliance; clay tile or a listed liner is used.

  • Fireplace hearth extension must be at least 16 inches in front and 8 inches at the sides.

  • Where the fireplace opening exceeds 6 square feet, the hearth extension must be at least 20 inches in front.

  • Fireplace dampers and smoke chambers must be constructed as required by code.

  • Factory-built fireplaces must be listed and installed per manufacturer instructions.

  • Chimneys must be supported on a foundation or structural support.