ICC B1 key terms
ICC B1 · Get comfortable with the vocabulary.
- Permit
- Related: Approved plans, Inspection, Stop-work order
A written authorization from the building department allowing specific construction work to begin. It records the approved scope and requires inspections before covered work is concealed or occupied.
- Approved plans
- Related: Permit, Inspection, Building official
Construction drawings and specifications reviewed and stamped by the building department. Work must follow them; changes affecting code compliance require review and written approval before construction proceeds.
- Inspection
- Related: Permit, Approved plans, Stop-work order
A building department review of completed work at required stages. The permit holder requests it, and work must be accessible for examination before it is covered or used.
- Stop-work order
- Related: Building official, Inspection, Permit
A written notice issued by the building official directing that construction stop because work is unsafe or violates code or permit conditions. Work may resume only after the issue is corrected and clearance is given.
- Building official
- Related: Stop-work order, Approved plans, Inspection
The appointed authority responsible for enforcing the building code. This person interprets code provisions, issues permits and orders, approves plans, and may authorize equivalent alternatives when code compliance is demonstrated.
- Setback
The minimum required horizontal distance between a building or structure and a lot line, street, or other specified line. Setbacks control placement and are measured as the code or approved plans require.
- Habitable space
- Related: Natural ventilation, Ceiling height, Emergency escape and rescue opening
A room or area used for living, sleeping, eating, or cooking. Bathrooms, closets, halls, storage areas, and similar spaces are generally not habitable space for code purposes.
- Natural ventilation
- Related: Habitable space, Natural light
Outdoor air supplied to a space through operable windows, doors, louvers, or other openings. The code specifies opening area and access so occupied spaces receive adequate fresh air.
- Natural light
- Related: Natural ventilation, Habitable space
Daylight admitted to a room through glazing or other approved openings. Required amounts are based on floor area, and some rooms may use artificial light alternatives where the code permits.
- Emergency escape and rescue opening
- Related: Habitable space
A window, door, or other opening that allows occupants to escape a sleeping room and allows rescuers to enter. It must meet minimum size, sill height, and operability requirements.
- Ceiling height
- Related: Habitable space
The clear vertical distance from finished floor to finished ceiling. Habitable rooms, halls, and other spaces must meet minimum heights, with limited exceptions for sloped ceilings and basements.
- Footing
- Related: Foundation wall, Frost depth, Pier
The widened base of a foundation that spreads building loads over a larger soil area. It must be sized, placed, and constructed to support the foundation without excessive settlement.
- Foundation wall
- Related: Footing, Frost depth
A wall that supports exterior or interior loads and transfers them to footings. It may retain soil and must resist water, frost, and lateral pressures as required by code.
- Frost depth
- Related: Footing, Foundation wall
The maximum depth to which soil is expected to freeze in a given area. Footings must extend below this depth, or be protected differently, to prevent frost heave damage.
- Pier
- Related: Footing, Foundation wall
A vertical foundation element, often isolated, that supports a concentrated load such as a post or beam. It extends to a footing or stable soil and must be sized for the load.
- Anchor bolt
- Related: Sill plate, Foundation wall
A bolt embedded in concrete or masonry to connect the foundation to wood framing or other structural elements. Its size, spacing, placement, and washers must match approved plans and code.
- Sill plate
- Related: Anchor bolt, Floor joist, Foundation wall
The horizontal wood member fastened to the foundation and supporting floor or wall framing. It must be anchored, protected from decay and termites, and sized for the loads.
- Floor joist
- Related: Subfloor, Girder, Sill plate
A repeated horizontal framing member that supports a floor and its loads. Joists must be sized, spaced, supported, and drilled or notched only within code limits.
- Girder
- Related: Floor joist, Pier
A primary horizontal beam that supports floor joists or other framing and transfers loads to columns, piers, or walls. It must be sized and supported according to approved plans.
- Subfloor
- Related: Floor joist
The structural panel or boards installed over floor joists to form a base for finish flooring. It must be thick enough, fastened, and supported to carry floor loads.
- Wall stud
- Related: Load-bearing wall, Top plate, Wall bracing
A vertical framing member in a wall that supports loads or provides a base for wall coverings. Stud size, spacing, grade, and height limits depend on loading and code tables.
- Load-bearing wall
- Related: Wall stud, Header
A wall that supports structural loads from floors, ceilings, or roof above in addition to its own weight. Removing or altering it requires engineering and approval.
- Header
- Related: Load-bearing wall, Wall stud
A horizontal structural member placed over an opening to carry loads above and transfer them to adjacent framing. Its size and bearing depend on span and load.
- Top plate
- Related: Wall stud, Ceiling joist, Roof rafter
The horizontal framing member at the top of a wall that ties studs together and supports ceiling or roof framing. It must be sized, lapped, and fastened as required.
- Wall bracing
- Related: Wall stud, Sheathing
A system of panels, braces, or sheathing that resists lateral loads such as wind and earthquakes. Required amounts and methods depend on wall location, construction, and exposure.
- Sheathing
- Related: Wall bracing, Weather-resistive barrier, Roof sheathing
Panels or boards fastened over studs, rafters, or joists to provide structural support and a base for coverings. Structural sheathing may also transfer lateral and diaphragm loads.
- Weather-resistive barrier
- Related: Sheathing, Flashing, Exterior siding
A membrane or material installed behind exterior wall coverings to prevent water from entering the wall assembly. It must be lapped, fastened, and integrated with flashing.
- Exterior siding
- Related: Weather-resistive barrier, Flashing
The outer wall covering that protects the building from weather and provides the finished appearance. It must be attached, spaced, and flashed to shed water and allow drying.
- Flashing
- Related: Weather-resistive barrier, Roof covering, Exterior siding
A water-resistant material installed at joints, edges, and penetrations to direct water away from the building. Correct flashing prevents moisture entry at roofs, walls, windows, and chimneys.
- Roof rafter
- Related: Ceiling joist, Collar tie, Roof sheathing
A sloping structural framing member that supports roof sheathing and roof coverings. Rafters must be sized, spaced, braced, and connected to resist gravity and lateral loads.
- Ceiling joist
- Related: Roof rafter, Collar tie, Top plate
A horizontal framing member that supports a ceiling and may tie opposing roof rafters together. It must be sized and connected to resist loads and rafter thrust where required.
- Collar tie
- Related: Roof rafter, Ceiling joist
A horizontal member connecting opposing roof rafters above the wall line. It helps resist rafter separation and thrust, with placement and size determined by the roof design.
- Roof sheathing
- Related: Roof rafter, Underlayment, Roof covering
Panels or boards fastened to rafters or trusses to support roof coverings and transfer loads. Thickness, span rating, fastening, and support must match code and manufacturer requirements.
- Roof covering
- Related: Underlayment, Drip edge, Flashing
The outermost material on a roof that sheds rain and snow. It must be approved for the slope, installed per manufacturer instructions, and supported by proper underlayment and flashing.
- Underlayment
- Related: Roof covering, Roof sheathing, Drip edge
A sheet material placed between roof sheathing and the roof covering. It provides a secondary water barrier and is required based on roof slope and covering type.
- Drip edge
- Related: Roof covering, Underlayment, Flashing
A metal or plastic strip at roof edges that directs water away from fascia and sheathing. It must be installed at eaves and gables where required and integrated with underlayment.
- Chimney
- Related: Flue, Fireplace, Chimney clearance
A vertical masonry or listed structure that carries smoke and gases from a fireplace or appliance to outdoors. It must have a lined flue, proper height, clearance, and support.
- Fireplace
- Related: Chimney, Flue
A masonry or listed hearth assembly designed to contain a fire and direct smoke into a chimney. Construction, clearances, hearth extension, and damper requirements depend on the type.
- Flue
- Related: Chimney, Fireplace, Chimney clearance
The passage or liner inside a chimney that conveys smoke and gases to the outdoors. It must be sized for the appliance, continuous, and kept clear of obstructions and combustible materials.
- Chimney clearance
- Related: Chimney, Flue, Fireplace
The required separation between a chimney or flue and combustible materials. Clearance protects framing from heat and is achieved by air spaces, insulation, or listed chimney assemblies.