Residual mixing water
Water remaining in concrete after cement hydration, available to evaporate or migrate; higher water-cement ratio leaves more free water and raises equilibrium relative humidity.
Capillary transport
Movement of liquid water through the fine pore network of concrete driven by surface tension and suction; dominant at high relative humidity and a major path for moisture rise.
Vapor diffusion
Transport of water vapor through concrete pores down a vapor pressure gradient, from warm or wetter zones toward cooler or drier zones, independent of liquid flow.
Equilibrium relative humidity
The stable RH the concrete pore air reaches for a given moisture content and temperature; it is the quantity ASTM F2170 approximates after probe equilibration.
Moisture-related coating failure
Blistering, bubbling, or debonding of coatings caused by vapor pressure buildup or water at the bond line; prevented by verifying substrate moisture before application.
F2170 probe depth
The probe tip is placed at a specified depth, commonly 40 percent of slab thickness for slabs on grade, to sample representative pore humidity rather than the dried surface.
Probe equilibration
The period after inserting the F2170 probe during which the sensor must stabilize with the concrete pore air before a valid reading is recorded.
Sleeve sealing
Sealing the top of the F2170 hole and the sleeve against the concrete so ambient air cannot enter and dilute the pore humidity being measured.
In-situ RH acceptance
Comparison of the F2170 relative humidity result to the flooring or coating manufacturer's published limit to determine whether the slab is acceptable for installation.
F2170 test location count
The standard sets a minimum number of test locations based on slab area and requires additional locations when results vary widely across the slab.
F1869 test setup
A pre-weighed calcium chloride dish is sealed under an airtight dome on a cleaned slab surface for a fixed exposure period to absorb vapor.
MVER units
Moisture vapor emission rate reported in pounds of water per 1000 square feet per 24 hours, or the metric equivalent, calculated from dish mass gain.
Surface preparation for F1869
The slab surface must be free of curing compounds, sealers, adhesives, and dust before placing the dish; contamination invalidates the emission result.
F1869 exposure period
The fixed time the sealed dish remains on the slab, typically about 60 to 72 hours, after which the dish is removed and weighed.
F1869 limitation
The test measures short-term vapor emission from the surface and does not directly measure in-situ relative humidity at depth in the slab.
F2420 surface RH
A sealed hood or chamber placed on the slab surface encloses an RH sensor, measuring surface relative humidity rather than humidity at depth.
F2659 moisture meter
A handheld electrical impedance or capacitance instrument giving relative readings used to screen and map moisture variation across a slab surface.
Relative meter readings
F2659 readings are instrument-specific and relative; they cannot be converted to RH or MVER without calibration to a quantitative method.
Screening versus acceptance
Surface methods map moisture and guide test placement; quantitative F2170 or F1869 results are used for specification acceptance.
Embedded metal interference
Rebar, conduits, and other embedded metal distort F2659 electrical readings, so measurements near them are unreliable and should be avoided.
Method selection rule
Choose F2170 when the product limit is in-situ RH, F1869 when the limit is MVER, and surface methods for screening and mapping.
Test timing
Testing is performed after curing and before flooring installation, when the slab moisture condition is representative and not affected by recent wetting.
Vapor retarder effect
A properly installed vapor retarder under a slab reduces vapor drive from the soil but does not eliminate moisture already in the concrete.
Environmental stability
Stable temperature and relative humidity in the test area during equilibration and exposure periods are required to obtain representative and repeatable results.
Test location distribution
Tests are spread across the slab and include areas of concern such as exterior walls, penetrations, and patched areas, following the standard's minimum count.
Reporting test method
The report identifies the standard used, test date, locations, slab thickness and depth, and ambient and slab conditions for each measurement.
F2170 reporting
Report equilibration time and the stability criterion met, along with the recorded relative humidity and slab temperature at each location.
F1869 reporting
Report exposure time, dish area, mass gain, and the calculated MVER with units for each test location.
Pass-fail interpretation
Results are compared to the manufacturer's published limit and stated as pass or fail, with any areas requiring mitigation identified.
Product-specific limits
Adhesives and coatings publish their own allowable in-situ RH or MVER values; the product's published limit governs, not a generic rule of thumb.
Vapor-reducing primer
A coating or primer system applied to a slab to reduce vapor transmission; it can raise the allowable limit only when specified as a complete system.
Silica dust control
Drilling and grinding concrete generate respirable silica; use wet methods or HEPA vacuum, plus eye and respiratory protection.