ICRI CSMT · Get comfortable with the vocabulary.

equilibrium relative humidity (ERH)

The stabilized relative humidity inside a sealed concrete slab hole after the material has equalized with the surrounding pore air, expressed as percent RH at a stated temperature and reported per ASTM F2170.

Related: in-situ probe method, pore water, moisture equilibrium
in-situ probe method

A field procedure that drills holes to a specified depth, lines them with a sleeve, seals the top, and inserts an electronic humidity sensor to measure internal RH after equilibration.

Related: equilibrium relative humidity (ERH), hole depth and conditioning, ASTM F2170
ASTM F2170

Standard test method for determining relative humidity in concrete floor slabs using in-situ probes; it specifies hole diameter, depth, conditioning time, sensor accuracy, and reporting.

Related: in-situ probe method, hole depth and conditioning, equilibrium relative humidity (ERH)
hole depth and conditioning

The required depth of the drilled test hole below the slab surface and the minimum time the sealed hole must sit before measurement, allowing the hole to reach moisture equilibrium with the concrete.

Related: ASTM F2170, in-situ probe method
calcium chloride test

A field test that seals a dish of hygroscopic calcium chloride to the slab surface and measures the mass of moisture absorbed over a set period, reported as emission rate.

Related: ASTM F1869, moisture vapor emission rate (MVER), surface-area dependence
ASTM F1869

Standard test method for measuring moisture vapor emission rate of concrete subfloor using anhydrous calcium chloride; defines specimen preparation, exposure duration, weighing, and calculation.

Related: calcium chloride test, moisture vapor emission rate (MVER)
moisture vapor emission rate (MVER)

The mass of water vapor leaving a concrete surface per unit area per unit time, typically expressed in pounds per 1000 square feet per 24 hours under the calcium chloride test conditions.

Related: calcium chloride test, ASTM F1869
surface-area dependence

The tendency of calcium chloride emission results to be influenced by the exposed dish area and slab conditions, so results from kits of differing dimensions are not directly interchangeable.

Related: calcium chloride test, ASTM F1869
surface moisture meter

A handheld electrical instrument placed on the concrete surface that infers moisture content from electrical impedance, capacitance, or resistance changes, giving relative rather than absolute values.

Related: ASTM F2659, comparative reading, non-destructive testing
ASTM F2659

Standard guide for preliminary evaluation of comparative moisture conditions of concrete slabs using non-destructive electrical impedance or capacitance meters, intended for screening rather than acceptance.

Related: surface moisture meter, comparative reading
ASTM F2420

Standard test method for determining relative humidity on the surface of concrete floor slabs using a sealed insulated hood enclosing a humidity sensor, measuring near-surface conditions.

Related: hood method, relative humidity at surface, ASTM F2170
hood method

A procedure that places an insulated enclosure with a humidity sensor against the slab surface and seals the perimeter, allowing trapped air to equilibrate with the concrete surface.

Related: ASTM F2420, relative humidity at surface
comparative reading

A measurement whose value is meaningful mainly when compared with other readings from the same instrument on the same slab, not as an absolute moisture content.

Related: surface moisture meter, ASTM F2659
relative humidity at surface

The humidity of air immediately above or trapped against a concrete surface, which reflects near-surface drying conditions and can differ from internal slab humidity.

Related: ASTM F2420, hood method, equilibrium relative humidity (ERH)
pore water

Water held within the capillary and gel pores of hardened concrete, which drives internal relative humidity and moves by diffusion, capillary flow, and vapor transport.

Related: capillary action, water-cement ratio, equilibrium relative humidity (ERH)
capillary action

The movement of water through fine interconnected pores driven by surface tension, drawing moisture upward or laterally through concrete and toward drier zones.

Related: pore water, permeability
water-cement ratio

The mass ratio of water to cementitious material in a concrete mix; higher values increase porosity, permeability, and the amount of free water available to evaporate.

Related: pore water, permeability, curing
permeability

A measure of how readily fluids pass through concrete under a pressure gradient; it depends on pore structure, cracks, and mix design and controls moisture migration rates.

Related: capillary action, water-cement ratio
curing

The controlled maintenance of moisture and temperature in fresh concrete to allow cement hydration; proper curing lowers porosity and reduces later moisture release.

Related: water-cement ratio, drying time
drying time

The period after concrete placement during which excess water evaporates before a moisture-sensitive floor covering is installed; it depends on thickness, mix, curing, and environment.

Related: curing, moisture equilibrium
moisture equilibrium

The state in which water movement within concrete and between concrete and its surroundings has stabilized, so measured humidity or emission values no longer change materially over time.

Related: drying time, equilibrium relative humidity (ERH)
vapor retarder

A sheet or coating placed beneath or on a slab to limit water vapor movement; when below the slab it reduces upward moisture drive from the subgrade.

Related: permeability, moisture vapor transmission
moisture vapor transmission

The general movement of water vapor through a material driven by vapor pressure differences, distinct from liquid water flow and often expressed as a rate.

Related: vapor retarder, moisture vapor emission rate (MVER)
scheduling of tests

Timing moisture tests after concrete has reached a representative condition, after curing and cleaning, and before floor covering installation, while allowing the required sensor conditioning period.

Related: site conditions, drying time, equilibrium relative humidity (ERH)
site conditions

The ambient temperature, humidity, ventilation, and building enclosure status present during testing and drying, which influence measured values and must be documented.

Related: scheduling of tests, drying time
test method selection

The process of choosing moisture tests based on slab type, floor covering requirements, project stage, and whether quantitative internal RH or surface emission data is needed.

Related: ASTM F2170, ASTM F1869, ASTM F2659
sampling plan

A documented layout defining the number and location of test points to represent the slab, including areas of different thickness, exposure, or construction history.

Related: test method selection, documentation
documentation

The complete record of methods, instruments, calibration, test locations, conditions, readings, and deviations that allows results to be verified and interpreted later.

Related: reporting, sampling plan, calibration
reporting

The formal presentation of test results including method standard, units, test locations, dates, ambient conditions, instrument data, and any limitations or exceptions.

Related: documentation, interpretation of results
interpretation of results

The reasoned comparison of measured moisture values with specification limits and product requirements, accounting for method differences, variability, and site conditions.

Related: reporting, manufacturer moisture limit
calibration

The verification of instrument accuracy against known references at defined intervals, with records kept to demonstrate that measurements are traceable and trustworthy.

Related: documentation, in-situ probe method
manufacturer moisture limit

The maximum moisture condition, stated as RH or emission rate, at which a flooring or coating manufacturer permits installation of its product over concrete.

Related: interpretation of results, moisture-sensitive flooring
moisture-sensitive flooring

Floor coverings such as resilient sheet, rubber, wood, and some coatings that can be damaged by trapped moisture, including adhesive failure, blistering, cupping, or mold growth.

Related: manufacturer moisture limit, vapor retarder
moisture mitigation system

A product or assembly, such as a topical vapor barrier or self-leveling underlayment, applied to reduce moisture emission before installing a moisture-sensitive floor covering.

Related: vapor retarder, manufacturer moisture limit
conflict of interest

A situation in which an inspector's financial or personal interests could bias test results or reporting; it must be disclosed and managed to preserve objectivity.

Related: professional practice, documentation
professional practice

Acting within one's competence, following applicable standards, maintaining impartiality, and communicating results honestly, including acknowledging uncertainty and method limitations.

Related: conflict of interest, interpretation of results
chain of custody

A documented record tracking test samples, instruments, or data from collection through reporting, supporting integrity and traceability of results.

Related: documentation, calibration