Ton of refrigeration

Rate of heat removal equal to 12,000 British thermal units per hour, roughly the cooling needed to melt one ton of ice in 24 hours. Equipment capacity in North America is commonly rated in tons.

Related: Sensible heat, Latent heat
Sensible heat

Heat that changes the temperature of a substance without changing its phase. In air conditioning, it is the portion of the load tied to dry-bulb temperature difference between room air and supply air.

Related: Latent heat, Dry-bulb temperature, Sensible heat ratio
Latent heat

Heat absorbed or released when a substance changes phase, such as water evaporating or vapor condensing, with no temperature change. In comfort cooling it is mostly the energy used to condense moisture removed from air.

Related: Sensible heat, Relative humidity, Dehumidification
Sensible heat ratio

The fraction of total coil load that is sensible heat, calculated as sensible load divided by total load. A low ratio means a large share of capacity goes to moisture removal rather than temperature drop.

Related: Sensible heat, Latent heat, Apparatus dew point
Dry-bulb temperature

The temperature of air measured by an ordinary thermometer, unaffected by moisture content. It is the value most people mean when they say room temperature and is plotted on the horizontal axis of a psychrometric chart.

Related: Wet-bulb temperature, Psychrometric chart, Relative humidity
Wet-bulb temperature

The lowest temperature air can reach by evaporating water into it, measured with a wetted sensor in moving air. It indicates the evaporative cooling potential and is used for evaporative coolers and condenser performance.

Related: Dry-bulb temperature, Dew point, Psychrometric chart
Dew point

The temperature to which air must be cooled, at constant moisture content, for water vapor to begin condensing. A surface colder than the dew point will sweat; cooling coils must run below it to remove moisture.

Related: Wet-bulb temperature, Relative humidity, Dehumidification
Relative humidity

The amount of water vapor in air expressed as a percentage of the maximum the air could hold at that temperature. It changes as air warms or cools even when the actual moisture content stays the same.

Related: Dew point, Humidity ratio, Dry-bulb temperature
Humidity ratio

The mass of water vapor carried in a given mass of dry air, usually stated in grains per pound or kilograms per kilogram. Unlike relative humidity, it does not change when air is simply heated or cooled.

Related: Relative humidity, Psychrometric chart, Latent heat
Psychrometric chart

A graph of moist air properties that lets you find dry-bulb, wet-bulb, dew point, humidity ratio, and enthalpy from any two known values. It is the standard tool for analyzing coil and air-mixing processes.

Related: Dry-bulb temperature, Wet-bulb temperature, Enthalpy
Enthalpy

The total heat content of moist air per unit mass of dry air, combining sensible heat and the latent heat of its moisture. Coil capacity can be found from the enthalpy difference between entering and leaving air.

Related: Psychrometric chart, Latent heat, Sensible heat
Apparatus dew point

The effective surface temperature of a cooling coil, found where the straight line between entering and leaving air conditions crosses the saturation curve. It shows how cold the coil must be to reach a target supply condition.

Related: Sensible heat ratio, Dew point, Bypass factor
Bypass factor

The fraction of air passing through a coil that does not contact the coil surface and leaves at essentially entering conditions. Lower values mean better coil performance and a supply temperature closer to the coil surface.

Related: Apparatus dew point, Cooling coil, Airflow
Refrigeration cycle

A repeating process in which refrigerant absorbs heat at low pressure and temperature, is compressed, rejects heat at high pressure, then expands back to low pressure. It moves heat from a cooled space to outdoor air.

Related: Compressor, Evaporator, Expansion valve
Compressor

The pump of a refrigeration system that raises refrigerant vapor from low to high pressure, adding energy so the vapor can reject heat to outdoor air. Common types include reciprocating, scroll, screw, and centrifugal.

Related: Refrigeration cycle, Condenser, Superheat
Evaporator

The indoor coil where low-pressure liquid refrigerant boils and absorbs heat from air passing over the fins. Its surface runs colder than the air dew point, so condensate forms and drains away.

Related: Cooling coil, Superheat, Refrigeration cycle
Condenser

The coil that rejects heat from hot refrigerant vapor to outdoor air or water, causing the refrigerant to condense into a liquid. Air-cooled and water-cooled designs are the two common arrangements.

Related: Compressor, Subcooling, Refrigeration cycle
Expansion valve

A metering device that drops refrigerant pressure from condensing to evaporating level and regulates flow to match load. Thermostatic and electronic types control flow by maintaining a set superheat at the evaporator outlet.

Related: Superheat, Evaporator, Refrigeration cycle
Superheat

The temperature of refrigerant vapor above its saturation temperature at the same pressure. Measured at the evaporator outlet, it confirms the expansion valve is feeding enough refrigerant to protect the compressor.

Related: Subcooling, Expansion valve, Compressor
Subcooling

The amount by which liquid refrigerant is cooled below its condensing temperature at the same pressure. Measured at the condenser outlet, it shows how much liquid is stacked in the condenser and helps confirm charge.

Related: Superheat, Condenser, Expansion valve
Cooling coil

A finned heat exchanger that removes heat and moisture from air passing across it. Its capacity depends on surface area, refrigerant or chilled-water temperature, and airflow, and it must drain condensate reliably.

Related: Evaporator, Bypass factor, Dehumidification
Airflow

The volume of air moved per unit time, usually cubic feet per minute or liters per second. Too little airflow causes coil icing and high temperature rise; too much reduces dehumidification and temperature drop.

Related: Static pressure, Cooling coil, Duct design
Static pressure

The outward push of air against duct walls, measured in inches of water column. External static pressure indicates the resistance a blower works against and is used to check duct sizing and filter loading.

Related: Airflow, Duct design, Fan curve
Duct design

The layout and sizing of air distribution passages to deliver required airflow with acceptable pressure loss, noise, and space use. Equal-friction and static-regain methods are common approaches to sizing trunk and branch ducts.

Related: Static pressure, Airflow, Diffuser
Diffuser

An outlet that spreads supply air into a room with controlled velocity and direction, promoting mixing before it reaches occupants. Ceiling, slot, and floor types are chosen to suit throw, drop, and noise limits.

Related: Return grille, Duct design, Air changes per hour
Return grille

An intake opening that draws room air back to the air handler, sized to keep face velocity and noise low. Poor return location can cause short-circuiting, where supply air returns before mixing with room air.

Related: Diffuser, Airflow, Air changes per hour
Air changes per hour

The number of times the full volume of a space is replaced with supply or outdoor air in one hour. It is used for ventilation checks, dilution of contaminants, and required exhaust in specialized rooms.

Related: Ventilation rate, Airflow, Outdoor air intake
Ventilation rate

The quantity of outdoor air supplied to a space per unit time or per person, set to control odors, carbon dioxide, and other contaminants. Codes give minimum rates that vary by occupancy type.

Related: Outdoor air intake, Air changes per hour, Economizer
Outdoor air intake

The louvered opening and damper through which fresh air enters a building's air system. Its location must avoid exhaust fumes, loading docks, and snow, and the damper must close tightly when not needed.

Related: Ventilation rate, Economizer, Damper
Economizer

A control strategy that uses cool outdoor air instead of mechanical cooling when outdoor conditions are favorable. Air-side economizers use damper modulation; water-side types use a fluid cooler or tower.

Related: Outdoor air intake, Damper, Enthalpy
Damper

A movable blade assembly inside ductwork or an opening that varies or stops airflow. Manual dampers balance branches; motorized dampers respond to controls for economizer, smoke, or zone functions.

Related: Outdoor air intake, Economizer, Variable air volume
Variable air volume

A system that holds supply temperature roughly constant while varying fan and box airflow to match zone loads. It saves fan energy but needs careful minimum airflow settings to maintain ventilation and avoid stratification.

Related: Airflow, Damper, Fan curve
Fan curve

A graph showing how a fan's airflow and pressure output relate, along with power and efficiency at each point. The operating point is where the fan curve intersects the system resistance curve.

Related: Static pressure, Airflow, Variable air volume
Furnace

A fuel-fired or electric appliance that heats air for distribution through ducts. Gas units are rated by input and output capacity, and steady-state efficiency reflects how much heat reaches the air.

Related: Heat exchanger, Combustion air, AFUE
Heat exchanger

In a furnace, the metal passages that separate hot combustion gases from the air being heated. Cracks or holes allow carbon monoxide into supply air, so inspection and combustion testing are essential.

Related: Furnace, Combustion air, Carbon monoxide
Combustion air

The air supplied to a burner to support complete burning of fuel. Inadequate supply causes incomplete combustion, soot, and carbon monoxide, and codes require a permanent source for confined spaces.

Related: Furnace, Heat exchanger, Carbon monoxide
Carbon monoxide

A colorless, odorless gas produced by incomplete combustion that binds to hemoglobin and can be fatal at low concentrations. It is the main safety reason for venting checks and combustion analysis on fuel-burning equipment.

Related: Combustion air, Heat exchanger, Draft
Draft

The pressure difference that moves combustion gases up a flue or chimney and out of the building. Natural-draft appliances rely on buoyancy, while induced-draft units use a fan to maintain safe venting.

Related: Carbon monoxide, Combustion air, Heat exchanger
AFUE

Annual fuel utilization efficiency, the percentage of fuel energy delivered as heat over a heating season, accounting for cycling and standby losses. Standard furnaces are around 80 percent; condensing models exceed 90 percent.

Related: Furnace, Heat exchanger, Heating load
Heating load

The calculated heat loss a building experiences on a design winter day, including transmission through the envelope and infiltration. It sets equipment capacity and is paired with the cooling load for sizing.

Related: Cooling load, Manual J, Degree day
Cooling load

The calculated rate of heat gain a building must remove on a design summer day, including solar, conduction, occupants, and equipment. It determines capacity and airflow, and differs from the connected equipment capacity.

Related: Heating load, Manual J, Sensible heat
Degree day

A measure of how far the average daily temperature falls below or rises above a base, summed over a season. Heating and cooling degree days estimate seasonal energy use and compare climates.

Related: Heating load, Cooling load, AFUE
Refrigerant

A fluid chosen to evaporate and condense at useful pressures and temperatures inside a refrigeration system. Modern selections favor low global-warming-potential blends, which require careful charging and handling.

Related: Refrigeration cycle, Superheat, Subcooling
Dehumidification

The removal of water vapor from air, usually by cooling it below its dew point on a coil or by desiccant absorption. Proper dehumidification requires adequate run time and airflow low enough for the coil to condense moisture.

Related: Latent heat, Dew point, Cooling coil
Manual J

A widely used residential method for calculating heating and cooling loads from envelope, orientation, and occupancy data. Its output sizes equipment, while separate methods size ducts and select equipment.

Related: Heating load, Cooling load, Airflow