F-Gas Category II (IE) study plan
F-Gas Category II (IE) · Give each week a clear focus.
8 weeks · About 6 hours per week
Legislation and obligations under F-Gas and ODS regulations
Classify a list of 20 common refrigerants as fluorinated GHG, ODS, or neither, citing the regulation that covers each
State the tCO2e leak-check thresholds (5, 50, 500) and the associated checking frequencies from memory
Identify the competent authority and the operator's core duties under the F-Gas and ODS regulations
Distinguish operator obligations from technician/certification obligations in three short scenarios
Your checkpoint
A one-page threshold and obligations table covering 5/50/500 tCO2e, checking intervals, record retention, and who holds each duty, scored against a self-marking key
Legislation and obligations under F-Gas and ODS regulations & Leak checking, containment and record keeping
Apply leak-check frequency rules to six worked equipment scenarios, including systems fitted with leak detection
Explain when a leak must be repaired, the follow-up check requirement, and the documentation that follows
List the mandatory fields of an equipment log and a refrigerant record
Draft compliant entries for a new installation and for a completed repair
Your checkpoint
Two completed mock record sheets (installation entry and repair entry) plus a written justification of the leak-check interval chosen for each of six scenarios
Leak checking, containment and record keeping & Recovery, recycling, reclamation and disposal of refrigerants
Select leak-detection methods appropriate to a given system type and justify the choice
Sequence a containment-first response to a detected leak, from isolation to recheck
Describe the recovery process steps and the equipment needed to recover a system to the required vacuum level
Differentiate recovery, recycling, and reclamation by what each process achieves and where each output may be used
Your checkpoint
A written leak-response procedure and a recovery-versus-recycling-versus-reclamation comparison card, each checked against a checklist of required technical points
Recovery, recycling, reclamation and disposal of refrigerants & Safe handling, charging, commissioning and decommissioning of equipment
Outline the decommissioning sequence for a small commercial system, from pump-down to cylinder labelling
Specify correct cylinder handling, filling limits, and labelling for recovered refrigerant
Explain the legal route for disposal of recovered refrigerant and of decommissioned equipment
Identify the personal protective equipment and ventilation controls required before opening a circuit
Your checkpoint
A timed 25-question mixed set on domains 3-4 scored at 80% or better, with every wrong answer rewritten as a correct one-line rule
Safe handling, charging, commissioning and decommissioning of equipment
Assemble a safe-work method statement for charging a system, covering purging, leak test, and post-charge checks
Calculate a charge weight from cylinder mass difference and verify it against the equipment label
Explain the hazards and controls for flammable and higher-pressure refrigerant classes
Describe the commissioning checks and handover records a Category II technician must complete
Your checkpoint
A complete method statement for a charging and commissioning job, including a filled-in cylinder mass-difference calculation and a handover checklist
Environmental impact of fluorinated greenhouse gases and ozone-depleting substances & Safe handling, charging, commissioning and decommissioning of equipment
Rank refrigerant groups by global warming potential and ozone depletion potential and explain what each metric measures
Explain how leaks from refrigeration and air-conditioning systems contribute to climate impact, using tCO2e arithmetic
Connect ODS phase-out obligations to the handling decisions made during service work
Identify three operational choices that reduce emissions on a typical plant room job
Your checkpoint
Five tCO2e conversion calculations with full working, plus a half-page summary linking GWP/ODP values to handling and containment decisions
Environmental impact of fluorinated greenhouse gases and ozone-depleting substances & Recovery, recycling, reclamation and disposal of refrigerants
Trace a recovered refrigerant cylinder from recovery through to destruction or reclamation, naming the records at each step
Explain the environmental rationale for recovery before venting is even considered
Resolve six borderline scenarios where venting, recycling, or reclamation could be argued
Produce accurate answers on end-of-life handling for both refrigerant and equipment
Your checkpoint
A process map of the recovered-refrigerant lifecycle with the record and legal requirement annotated at each stage, plus written rulings on the six scenarios
Legislation and obligations under F-Gas and ODS regulations & Environmental impact of fluorinated greenhouse gases and ozone-depleting substances & Leak checking, containment and record keeping & Recovery, recycling, reclamation and disposal of refrigerants & Safe handling, charging, commissioning and decommissioning of equipment
Complete two full timed mock exams under exam conditions and mark them strictly
Re-teach the three weakest sub-topics using your own notes only
Recite thresholds, record fields, and recovery definitions without prompts
Confirm readiness per domain against a self-audit checklist
Your checkpoint
Two marked mock papers with a scored-by-domain breakdown showing 80% or higher overall and no domain below 70%
Milestones
Week 2: Without notes, state the 5/50/500 tCO2e thresholds, their leak-check intervals, and four mandatory log fields
Week 4: Score 80% or higher on the timed mixed set for domains 3-4, with no repeat errors from week 3
Week 6: Complete five tCO2e conversions correctly and explain recovery-versus-reclamation from memory