IE F-Gas Category IV study materials
IE F-Gas Category IV study resources

IE F-Gas Category IV study plan

IE F-Gas Category IV · Give each week a clear focus.

8 weeks · About 7 hours per week

Week 1

Environmental impact and legal framework of fluorinated greenhouse gases & Properties, identification and safe handling of refrigerants

  • Explain how GWP values translate into CO2-equivalent tonnes and calculate the CO2e for at least five refrigerant charges of varying size

  • List the main obligations placed on operators by the EU F-Gas Regulation (leak checks, record keeping, certified personnel, recovery) and state which apply to Category IV work

  • Distinguish the refrigerant families (HFCs, HFOs, HCFCs, natural refrigerants) and classify ten common refrigerants by family and GWP band

  • Define the terms ODP, GWP, TEWI and quota in your own words without reference material

Your checkpoint

A one-page reference sheet with CO2e worked examples and a table of ten refrigerants showing family, GWP and legal status

Week 2

Properties, identification and safe handling of refrigerants & Environmental impact and legal framework of fluorinated greenhouse gases

  • Describe the pressure-temperature relationship for at least three common refrigerants and explain what saturation, superheat and subcooling mean in practice

  • Identify refrigerant hazards: flammability (A2L/A3), toxicity (B classifications), asphyxiation risk and oil compatibility

  • Read a cylinder label and safety data sheet to extract GWP, hazard statements and filling ratio limits

  • Match each refrigerant to its typical application and the correct lubricant type

Your checkpoint

A completed comparison table of six refrigerants covering PT behaviour, safety class, lubricant and typical use, plus five label-reading questions you wrote and answered

Week 3

Leak checking, record keeping and reporting obligations & Environmental impact and legal framework of fluorinated greenhouse gases

  • State the leak-check frequency rules by CO2e threshold and the conditions that allow extended intervals

  • Explain how leak detection systems and the associated inspection exemptions change the schedule

  • Draft a compliant equipment log entry from a simulated service visit, including all mandatory fields

  • Calculate the CO2e threshold at which a given refrigerant charge first triggers a leak-check obligation

Your checkpoint

A model equipment record sheet and a one-page leak-check schedule decision tree covering the main thresholds

Week 4

Leak checking, record keeping and reporting obligations & Properties, identification and safe handling of refrigerants

  • Demonstrate correct use of at least two leak detection methods (electronic detector, soap solution, UV dye) and state the limitations of each

  • Describe the procedure for a systematic leak test on a split system from service valves to indoor unit

  • Record a found leak accurately, including location, severity and corrective action taken

  • Explain the reporting chain after a leak is detected and what must be documented if repair is deferred

Your checkpoint

A written leak-detection procedure for one equipment type plus a filled-in mock leak report with findings and follow-up actions

Week 5

Recovery, containment and disposal of refrigerant and equipment & Leak checking, record keeping and reporting obligations

  • Explain the recovery, recycling and reclaiming distinction and when each is permitted

  • Describe the recovery procedure for a small split system, including hose connection order, purging and cylinder handling

  • State the legal requirements for evacuating and decommissioning equipment before disposal, including who may handle the refrigerant

  • List the documentation required when refrigerant is transferred to another party

Your checkpoint

A step-by-step recovery and decommissioning checklist for a domestic split system with the associated paperwork template

Week 6

Recovery, containment and disposal of refrigerant and equipment & Health and safety, personal protective equipment and emergency procedures

  • Identify the correct recovery cylinder type, filling limits and the reason overfilling is dangerous

  • Explain how to prevent refrigerant release during hose disconnection and cylinder changeover

  • Describe safe storage and transport rules for recovered refrigerant cylinders

  • Outline the hazards of mixing refrigerant types and how to avoid cross-contamination in recovery equipment

Your checkpoint

A recovery practical self-assessment: a numbered procedure you can perform unaided, with a list of five error scenarios and the correct response to each

Week 7

Health and safety, personal protective equipment and emergency procedures & Recovery, containment and disposal of refrigerant and equipment

  • Select the correct PPE for handling refrigerants and explain the protection each item provides

  • Describe first aid for frostbite, eye contact and inhalation exposure, and the actions to take on suspected asphyxiation in a plant room

  • Explain the risks of working in confined spaces and the precautions required before entering

  • State the safe working practices for brazing, pressure testing and handling pressurised cylinders

Your checkpoint

A personal emergency response card covering five incident types with immediate actions, plus a PPE selection checklist

Week 8

Environmental impact and legal framework of fluorinated greenhouse gases & Properties, identification and safe handling of refrigerants & Leak checking, record keeping and reporting obligations & Recovery, containment and disposal of refrigerant and equipment & Health and safety, personal protective equipment and emergency procedures

  • Answer a full set of mixed practice questions across all five domains under timed conditions

  • Review every incorrect answer and write the underlying rule or fact it tested

  • Re-derive the key thresholds, frequencies and CO2e calculations from memory

  • Identify your two weakest areas and complete targeted revision on each

Your checkpoint

A timed mock result with a written error log and a final one-page summary of thresholds, formulas and procedures

Milestones

Week 2: Without notes, name the GWP band and safety class of five common refrigerants and calculate the CO2e of a 5 kg charge of one of them

Week 4: Given a charge size and refrigerant, state the leak-check interval and list the mandatory fields of the equipment record, scoring at least 80% on a self-made quiz

Week 6: Walk through the recovery procedure aloud from memory, including cylinder filling limits and hose disconnection order, with no critical step missed

Week 8: Score at least 80% on the timed mixed mock and show a completed error log covering every missed question