- Plot ratio
- The ratio of total gross floor area of a building to the area of its site. Local plans set maximum plot ratios to control density and building bulk.
- Site survey
- A measured record of a site's boundaries, levels, contours, existing structures, services, and access. It forms the base drawing for all subsequent design work.
- Safe bearing capacity
- The allowable pressure that ground can carry without excessive settlement or shear failure. It is established by ground investigation and determines foundation type and size.
- Exempted development
- Development that does not require planning permission because it falls within stated limits, such as small domestic extensions. It must still comply with building regulations.
- Thermal conductivity
- The rate at which heat passes through a material, measured in W/m·K. Lower values indicate better insulation, and it is used to calculate thermal resistance of a layer.
- U-value
- The overall rate of heat transfer through a building element, in W/m²·K. It is the reciprocal of the sum of all layer resistances plus surface resistances.
- Concrete strength class
- A designation such as C25/30 giving characteristic cylinder and cube strengths in N/mm² at 28 days. It guides structural specification and mix design.
- Damp-proof course
- An impermeable layer built into a wall to stop moisture rising by capillary action. It is lapped with the damp-proof membrane under the ground floor.
- Anisotropic timber
- Timber has different strength and shrinkage properties along and across the grain. It is strongest parallel to grain and shrinks most in the tangential direction.
- Cavity wall construction
- Two masonry leaves separated by a cavity, tied together with wall ties. The cavity may hold insulation and drains moisture, with weep holes above flashings.
- Raft foundation
- A reinforced concrete slab spread across the whole footprint, distributing load over weak or variable ground. It is used where strip foundations would settle unevenly.
- Cold roof
- A roof with insulation at ceiling level and a ventilated void above it. Ventilation removes moisture that would otherwise condense on the cold underside of the deck.
- Fire compartmentation
- The division of a building into fire-resisting compartments by walls, floors, and doors. It limits fire and smoke spread and protects escape routes.
- Stair rise and going
- The vertical rise and horizontal tread of a stair. Two rises plus one going should total roughly 550–700 mm for comfortable, safe use.
- Bending moment formula
- For a simply supported beam with uniform load w over span L, the maximum bending moment is wL²/8 at midspan. It sets the required section modulus.
- Bending stress equation
- Bending stress equals bending moment divided by elastic section modulus, σ = M ÷ Z. It must stay below the design strength of the material.
- Slenderness ratio
- Effective length divided by radius of gyration. Higher values reduce compressive resistance, so columns need restraint about both axes.
- Triangulation for stability
- Bracing members forming triangles prevent a rectangular frame from distorting. Braced frames and shear walls resist lateral loads such as wind.
- Dead and live loads
- Dead load is the permanent self-weight of construction; live load is the imposed occupancy and use load. Both are combined with partial safety factors in design.
- Embodied carbon
- Total greenhouse gas emissions associated with extracting, manufacturing, transporting, constructing, and disposing of building materials. It is assessed by life cycle assessment.
- Thermal bridging
- Localised high heat loss where insulation is interrupted, such as at junctions and lintels. Accredited details and continuous insulation reduce it.
- Airtightness testing
- A pressure test measuring air leakage at 50 Pa, expressed as air changes per hour or m³/h·m². It identifies gaps that increase heat loss and condensation risk.
- Sustainable drainage systems
- Techniques that manage rainwater close to where it falls through infiltration, attenuation, and flow control. They reduce flood risk and pollution compared with direct connection.
- Overheating risk
- The likelihood that internal temperatures exceed comfort limits, driven by solar gain, glazing area, orientation, and ventilation. Thermal mass and shading reduce it.
- Coefficient of performance
- The ratio of heat delivered by a heat pump to the electrical energy consumed. Lower flow temperatures and well-insulated buildings raise the COP.
- Mechanical ventilation with heat recovery
- A balanced system that extracts stale air and supplies fresh air while transferring heat between the two streams. It typically recovers 70–90% of exhaust heat.
- Rainwater harvesting
- Collection and storage of roof runoff for non-potable uses such as WC flushing and irrigation. It requires filtration, storage, and a backup mains supply.
- Building energy rating
- A certificate rating a building's energy performance on a defined scale. It is based on fabric, services efficiency, renewables, and assessed energy demand.
- Thermal resistance formula
- Resistance R equals thickness d divided by thermal conductivity λ, in m²·K/W. Layer resistances are summed with surface resistances to find the U-value.
- Fabric heat loss
- Heat lost through the building envelope, calculated as the sum of U-value times area for each element, multiplied by the temperature difference.
- Interstitial condensation
- Condensation forming inside a construction when water vapour reaches a layer below dew point. A vapour control layer on the warm side and ventilation reduce the risk.
- Degree days
- A measure of how cold a climate is over a season, based on the difference between a base temperature and mean outdoor temperature. It estimates heating energy use.
- Orthographic projection
- A method of drawing separate plan, elevation, and section views of a building. First-angle and third-angle conventions arrange the views differently on the sheet.
- Drawing scale notation
- A ratio such as 1:50 stating that one unit on the drawing represents fifty units on the building. Details use larger scales than site plans.
- Title block
- A panel on every drawing recording project name, drawing number, scale, revision, date, and author. It makes drawings traceable and controls revisions.