RGII Domestic Gas Safety flashcards
RGII Domestic Gas Safety · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Gas Safety (Installation and Use) Regulations
- UK regulations governing the safe installation, maintenance and use of gas fittings and appliances in domestic and commercial premises, placing duties on installers, landlords and users.
- Landlord gas safety check interval
- A landlord must have every relevant gas appliance and flue checked for safety at intervals of no more than 12 months and give the record to tenants within 28 days.
- Regulation 36 bathroom restriction
- No gas appliance may be installed in a room used as a bathroom or shower room unless it is a room-sealed appliance, protecting occupants from combustion products and gas escape.
- BS 6891 scope
- British Standard covering the installation of low-pressure gas pipework of up to 35 mm nominal size in domestic and similar premises, including testing and purging requirements.
- Relative density of natural gas
- Natural gas is about 0.6 times as dense as air, so it rises and disperses at high level; this affects where leaks accumulate and how ventilation is designed.
- Relative density of LPG
- Propane has a relative density of roughly 1.5-2.0, so it is heavier than air and collects in low-lying areas such as basements, pits and drains.
- Complete combustion equation for methane
- CH4 + 2O2 produces CO2 + 2H2O; each volume of methane needs about two volumes of oxygen, roughly ten volumes of air.
- CO/CO2 ratio threshold
- A flue gas analyser ratio above 0.004 indicates incomplete combustion and a potentially unsafe appliance, requiring investigation and possible isolation.
- Flammable limits of natural gas
- Natural gas is flammable in air between approximately 5% and 15% by volume; below or above this range the mixture will not ignite.
- Pipework sleeving requirement
- Where gas pipe passes through a wall, floor or cavity, a sleeve must be fitted and sealed to the structure, with the annular space left open so leaking gas can disperse.
- Let-by test purpose
- A let-by test checks that the meter valve or test nipple is not passing gas before a tightness test, preventing a false result from a leaking internal valve.
- Tightness test medium
- Tightness tests use air or inert gas, never gas; test pressure and permissible drop are taken from BS 6891 tables based on installation volume and duration.
- Purging new pipework
- Purging displaces air from new or altered pipework with gas before lighting; the volume is calculated from pipe internal volume and the required number of volume changes.
- Emergency control valve location
- The ECV is fitted at the point where the service pipe enters the premises or on the meter outlet, must be readily accessible and operable without tools.
- Meter regulator outlet pressure
- For natural gas, the meter regulator outlet pressure should typically be within about 19-23 mbar; the operating pressure at the appliance is checked at its test point.
- Main protective bonding position
- Main protective bonding of metallic gas pipework must be within 600 mm of the meter outlet on the consumer side, in accordance with the IET Wiring Regulations.
- Gas escape at meter procedure
- If a leak is suspected at the meter or service, turn off the ECV, ventilate the area, avoid flames and electrical switches, and notify the gas transporter.
- Gas rate check calculation
- The gas rate is measured from the meter dial over a timed period and converted to kW using the calorific value of the gas and the meter conversion factor.
- Commissioning operating pressure check
- The burner operating pressure is measured at the appliance test point and compared with the data plate value; it must fall within the manufacturer's tolerance.
- Room-sealed appliance definition
- A room-sealed appliance takes combustion air directly from outside and discharges products outside, so it does not draw air from the room it serves.
- Servicing heat exchanger inspection
- Servicing includes inspecting the heat exchanger, burner, seals and flue for damage or blockage, cleaning as needed and confirming combustion performance with an analyser.
- Flue terminal distance from opening
- BS 5440 Part 1 specifies minimum terminal distances, including about 300 mm from an opening window or door and 600 mm from a boundary or neighbouring building.
- Draught diverter function
- A draught diverter on an open-flued appliance prevents down-draught affecting combustion and allows combustion products to spill into the room if the flue becomes blocked.
- Flue flow test method
- A smoke pellet is burned in the appliance flue to confirm the flue draws correctly and that smoke is discharged at the terminal, not into the room.
- Spillage test procedure
- A flame or smoke is held at the draught diverter after the appliance has run; products must be drawn into the flue, with no spillage into the room.
- Flue terminal guard requirement
- A terminal guard must be fitted where the flue terminal is accessible to the public or could be touched, to prevent contact with hot or sharp components.
- Immediately Dangerous classification
- An ID situation poses an immediate risk to life or property; gas must be shut off, the appliance isolated, a warning notice issued and the customer informed not to use it.
- At Risk classification
- An AR situation is a fault that could become dangerous; the appliance should be isolated, a warning notice issued and the customer advised of the defect and required action.
- Warning notice contents
- A warning notice records the defect, date, engineer details and action taken; the customer should sign to acknowledge receipt and a copy is retained.
- Carbon monoxide alarm guidance
- CO alarms should be fitted in rooms with open-flued appliances and in sleeping areas where guidance requires; an alarm does not replace correct servicing and checks.
- Reconnection after ID classification
- An appliance classified ID may only be reconnected once the defect has been rectified, the appliance retested and found safe, and the customer informed.
- Combustion analysis record
- Combustion analysis records CO, CO2, O2 and the CO/CO2 ratio; results are compared with manufacturer limits and retained as part of the commissioning or service record.