IMSA Traffic Signal II flashcards
IMSA Traffic Signal II · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Warrant 1
- The MUTCD Eight-Hour Vehicular Volume warrant, satisfied when traffic volumes on both the major and minor approaches exceed the specified thresholds for eight hours of an average day.
- Warrant 3
- The MUTCD Peak Hour Vehicular Volume warrant, met when both the minor-street volume and the major-street approach volume exceed their limits during any single hour.
- Overhead signal head clearance
- The bottom of a signal housing and its attachments installed over a roadway must be at least 15 feet above the pavement to clear vehicles.
- One primary signal per through lane
- MUTCD requires a primary signal face for each through lane, located over or as close as practicable to that lane so drivers can see their assigned indication.
- Mast arm wind load design
- Poles, mast arms, and span wires are sized for wind load using AASHTO LTS with the signal, sign, and luminaire loads given on the design plans.
- Verify plan bar scale
- Dimensions must be checked against the printed bar scale, because scaling from a reduced, re-plotted, or scanned sheet produces inaccurate measurements and layout errors.
- NEC conduit fill limit
- NEC Chapter 9 permits no more than 40 percent fill in a raceway containing three or more conductors, and it also sets minimum bend radius and pull-point rules.
- Anchor bolt torque
- After the pole is plumbed on its leveling nuts, the anchor bolt nuts are tightened to the torque value specified by the pole manufacturer before grouting.
- Equipment grounding conductor
- The insulated conductor that bonds each metal pole, cabinet, and device to the service ground, as required by NEC Article 250 for fault current return.
- Trench protective system
- OSHA 29 CFR 1926 Subpart P requires sloping, shoring, or a trench box for excavations 5 feet deep or more to protect workers from cave-in.
- Loop lead-in twisting
- Lead-in cable from a detector loop is twisted about four to six turns per foot so induced noise from nearby power conductors cancels and does not cause false calls.
- Cable pulling lubricant
- Lubricant reduces friction during installation; exceeding the cable's maximum pull tension or minimum bend radius will stretch or damage the conductors and jacket.
- Foundation cure before erection
- Poles are not set until the concrete foundation reaches its specified cure period or strength, commonly seven days or 75 percent of design compressive strength.
- Yellow change interval formula
- Y equals perception-reaction time plus V divided by (2a + 64.4g), where V is approach speed in mph, a is deceleration in ft/s², and g is grade.
- Red clearance interval formula
- R equals (W + L) divided by V, where W is the distance from the stop line to the far side of the conflicting area and V is speed in feet per second.
- Passage time
- The vehicle extension interval, typically 2.0 to 3.0 seconds, that holds a phase green after a detector actuation while the vehicle travels to the stop line.
- Minimum recall
- A controller setting that places a call for a phase every cycle so the phase is always served, even when no detector actuation occurs.
- Coordination offset
- The time shift applied to a coordinated controller's cycle relative to system time zero, used so platoons of vehicles arrive during the green interval.
- Conflict monitor (MMU)
- A device that monitors field outputs for conflicting greens, absence of red, and improper voltage, and forces the intersection to flashing operation when a fault occurs.
- NEMA TS-2 controller
- A controller standard using A, B, and C harness connectors and SDLC serial links to detectors and the monitor, replacing the parallel wiring of TS-1.
- Protected-permissive left turn
- Left-turn operation in which the movement runs protected on a green arrow and permissive during the opposing through green, shown by a flashing yellow arrow.
- Conflict monitor fault log
- The stored fault code shown on the monitor after a trip; it must be recorded before reset, because resetting clears the diagnostic history.
- Loop inductance baseline
- A healthy detector loop reads roughly 100 to 800 microhenries; a large deviation from the recorded installation value indicates an open or shorted loop.
- Phantom LED glow
- Faint illumination of an LED indication caused by leakage current in the field wiring, cured by repairing the leakage path or adding a bleeder resistor.
- No-green troubleshooting order
- Check detector actuation first, then call registration at the controller, then recall and coordination settings, and finally field wiring and the LED or lamp module.
- Cabinet preventive maintenance
- Scheduled cabinet service includes replacing fan filters, renewing desiccant, checking surge arrestors, verifying battery voltage, and torquing terminal connections.
- Ground fault isolation
- Disconnect field circuits and megger each conductor to ground; a sharp drop from the installation baseline resistance points to moisture intrusion or damaged insulation.
- Taper length formula
- L equals W times S for speeds of 40 mph or less, and L equals W times S squared divided by 60 for 45 mph or more, with W in feet.
- Buffer space
- The unoccupied area in a temporary traffic control zone between the work space and the traffic space that provides recovery distance for errant vehicles.
- High-visibility apparel
- ANSI/ISEA 107 Class 2 or Class 3 garments are required for workers exposed to traffic while operating within the highway right-of-way.
- Flagger STOP/SLOW paddle
- The standard retroreflective hand-signaling device used by flaggers to stop and release traffic, used with a clear sight line to approaching drivers.
- Activity area
- The portion of a temporary traffic control zone where work occurs, containing the work space, the buffer space, and the traffic space.