Odisha CHSE +2 Plumber General (VOC-ITV) study materials
Odisha CHSE +2 Plumber General (VOC-ITV) study resources

Odisha CHSE +2 Plumber General (VOC-ITV) cheat sheet

Odisha CHSE +2 Plumber General (VOC-ITV) · Keep the key ideas within reach.

Quick reference

Plumbing Tools, Materials and Safety Practices

  • Pipe wrench sizing rule: choose a wrench whose jaw opening exceeds the pipe's outside diameter by about 10-15 mm; a 350 mm wrench suits pipes up to 32 mm OD, a 450 mm wrench up to 50 mm OD.

  • Hacksaw blade selection: 18 TPI for steel and GI pipe above 25 mm, 24 TPI for copper and thin-wall tube, 32 TPI for PVC and thin brass; blades cut on the forward stroke.

  • Pipe cutter wheel pressure: tighten the knob a quarter turn per revolution of the cutter; over-tightening burrs the pipe wall and raises the burr that must be reamed out.

  • Torque reference for threaded joints: 25-40 N·m for 15-25 mm GI fittings, 60-90 N·m for 32-50 mm; excess torque splits cast fittings and strips threads.

  • PPR fusion temperatures: heating plate at 260 ± 5 °C, heating time about 5 s for 20 mm, 7 s for 25 mm, 12 s for 32 mm; cooling time at least 4 min before pressure testing.

  • Solvent cement for PVC: apply a thin even coat to both socket and spigot, assemble with a quarter-turn twist, hold 30 s, cure 24 h before pressure test at full working pressure.

  • Confined-space entry order: test atmosphere (O2 19.5-23.5 %, LEL below 10 %, H2S below 10 ppm), ventilate, isolate, then enter with a standby attendant and retrieval line.

  • Leak-detection soap solution ratio: about 1 part liquid detergent to 10 parts water; bubbles indicate gas or air leaks at 0.5 bar test pressure or above.

  • Copper tube annealing: heat to dull red (about 600 °C) and cool in air to soften for bending; do not quench in water if the tube is to be re-hardened for pressure service.

Quick reference

Sanitary Fittings, Fixtures and Appliances

  • Water closet flush volumes: 6/3 L dual-flush and 4.5 L single-flush are common Indian market ratings; 10 L cisterns are legacy and being phased out.

  • Wash basin trap seal must be 40-50 mm; a shallower seal allows sewer gas to pass, a deeper seal slows flow and collects debris.

  • Floor trap (nahani trap) grating size commonly 100 x 100 mm with 50 mm outlet; the trap seal is 50 mm and it must be accessible for rodding.

  • Water heater (geyser) pressure-relief valve setting: 6-8 bar for domestic storage units, with the expansion pipe discharging to a safe drain, never capped.

  • Bib tap and pillar tap flow: 15 mm nominal inlet gives about 0.15-0.2 L/s at 1 bar; 20 mm inlet about 0.3 L/s.

  • WC connection dimensions: 100 mm soil pipe outlet, 32-40 mm flush pipe from cistern, floor flange set level with finished floor tile.

  • Angle valve (stop cock) is fitted on the supply to each fixture so the fixture can be isolated without shutting the riser.

  • Indian standard reference for sanitary fittings is IS 2556 series (vitreous china sanitary appliances); check the IS mark and batch on delivered ware.

Quick reference

Water Supply Systems and Pipe Layout

  • Static head formula: pressure (bar) = height (m) x 0.0981; a 10 m column gives about 0.98 bar at the base.

  • Minimum residual pressure at the ferrule of the topmost fixture is 1.5-2 m (about 0.15-0.2 bar) for a direct system.

  • Overhead tank capacity rule: 100-135 litres per person per day for domestic use; size tank = persons x 135 L plus 20 % reserve.

  • Down-take pipe sizing guide for a small house: 25 mm main, 20 mm branch to a group of fixtures, 15 mm to individual taps.

  • Flow velocity limit in supply pipes is 1.5-2.0 m/s to control noise and erosion; above 2.5 m/s water hammer and erosion-corrosion appear.

  • Air gap between the supply pipe outlet and the tank overflow level must be at least the pipe diameter, and never less than 25 mm.

  • Gate valve is used for isolation (fully open or shut), globe valve for throttling; never use a gate valve to regulate flow.

  • Water hammer arrestor is placed close to the quick-closing valve; the arrestor's air charge should equal the static line pressure.

Quick reference

Sanitary Drainage and Sewerage Systems

  • Gradient rule: 100 mm drain at 1 in 60 to 1 in 100, 150 mm drain at 1 in 100 to 1 in 150; flatter than 1 in 200 causes solids deposition.

  • Self-cleansing velocity in a drain is 0.6-0.75 m/s at design flow; below 0.6 m/s solids settle.

  • Stack sizing: 100 mm stack serves about 20 WC equivalents; a 75 mm stack about 8; a 50 mm waste pipe about 3 fixtures.

  • Vent pipe sizing: the vent must be at least half the diameter of the drain it serves and never smaller than 32 mm.

  • Inspection chamber spacing: not more than 12 m on a straight run, and at every change of direction greater than 45 degrees.

  • Gully trap seal 50 mm, intercepting trap with a fresh-air inlet at the property boundary; the drain invert at the boundary must be at least 450 mm deep.

  • Two-pipe system separates soil (WC) from waste (bath, sink); one-pipe system uses a single stack with a relief vent.

  • Manhole cover class selection: light duty (LD) for footpaths, medium duty (MD) for driveways, heavy duty (HD) for roads.

Quick reference

Pipe Joining, Fabrication and Installation

  • Threaded joint sequence: cut square, ream the burr, cut BSP threads with a die, apply PTFE tape clockwise (2-3 turns) or jointing compound, tighten to 1-2 turns past hand-tight.

  • BSP thread standard: 15 mm pipe = 1/2 in BSP, 20 mm = 3/4 in, 25 mm = 1 in; thread length about 18-20 mm for 15-25 mm sizes.

  • Soldered copper joint clearance is 0.05-0.15 mm; flux must be applied sparingly and the joint cleaned after soldering to remove flux residue.

  • Compression fitting tightening: hand-tight plus 1 to 1.25 turns with a spanner; over-tightening crushes the olive and causes leaks.

  • Pipe support spacing: 15-25 mm copper or GI horizontal runs at 1.8-2.4 m; PVC at 1.0-1.5 m; vertical runs at every floor level.

  • Expansion allowance for PPR: about 0.15 mm per metre per °C; a 10 m run at 50 °C rise needs about 75 mm of expansion, absorbed by a loop or offset.

  • Pressure test: 1.5 times working pressure for at least 1 hour, or 1.0 bar for 30 min for a domestic installation; no drop beyond 0.05 bar is acceptable.

  • Fabrication drawing take-off: centre-to-centre length minus fitting allowances gives the cut length; subtract the socket depth at each end for push-fit joints.

Quick reference

Plumbing Repairs, Maintenance and Leak Detection

  • Leak diagnosis order: isolate the fixture, check the visible joint, then check the concealed run with a dampness meter or thermal camera before opening the wall.

  • Drip rate estimate: 1 drop per second is about 0.05 L/min, which is about 26 m³ per year of water loss; fix drips early.

  • Cistern running continuously usually means a perished flush valve washer or a mis-set float valve; check the overflow level against the float setting.

  • Frozen or blocked trap remedy: rod with a 6 mm spring auger, then flush with 5 L of water; do not use caustic soda on a plastic trap above 60 °C.

  • Pipe freeze protection: lag exposed runs, keep a trickle running on the coldest nights, and open cabinet doors to warm internal runs.

  • Noise in pipes (water hammer) is fixed by fitting an arrestor, replacing a worn washer, or reducing the pressure to below 3 bar at the fixture.

  • Sewer smell indoors indicates a dry trap, a broken vent, or a cracked drain; refill traps and smoke-test the drainage system to locate the fault.

  • Repair log: record date, location, fault, part replaced, and test result; this shortens the next diagnosis and supports warranty claims.

Quick reference

Drawing, Estimation and Costing

  • Scale reading: 1:50 means 1 mm on the drawing equals 50 mm on site; a 20 mm drawn length is 1.0 m actual.

  • Pipe length take-off = sum of horizontal runs + vertical risers + 5-10 % wastage for cutting and offcuts.

  • Fixture count method (Hunter's curve) converts fixture units to probable flow; a WC is 4-6 fixture units, a wash basin 1-2.

  • Rate build-up: material cost + labour cost + overheads (10-15 %) + contractor profit (10 %) + GST as applicable.

  • Labour norms: a plumber plus helper installs about 8-12 fixture points per day in a domestic building.

  • Bill of quantities must list item description, unit (m, no., set), quantity, rate, and amount; measured lengths are taken to the nearest 0.01 m.

  • Contingency in an estimate is normally 5-10 % of the estimated cost, shown as a separate line.

  • Isometric plumbing drawing uses standard symbols: circle with cross for a floor drain, triangle for a hose bib, filled circle for a gate valve.

Quick reference

Employability Skills

  • Communication sequence on a job: confirm the work order, state the time and material needed, report completion with a test result.

  • Personal protective equipment set for plumbing: safety helmet, goggles, gloves, ear plugs when cutting, safety footwear, and a respirator when solvent cement is used.

  • First aid for solvent cement in the eye: irrigate with clean water for at least 15 minutes and seek medical help; do not rub the eye.

  • Workplace 5S: sort, set in order, shine, standardise, sustain; tools go back to the marked place at the end of each shift.

  • Electrical safety: use 110 V or RCD-protected tools on site, and never work on a wet floor with an unearthed tool.

  • Team communication: use a hand signal or radio for valve operation; confirm the valve tag number before turning.

  • Time management on a service call: 10 min diagnosis, 30 min repair, 10 min test and clean-up is a workable standard for a simple leak.

  • Record keeping: a job card with customer signature protects both the worker and the customer in a dispute.

Quick reference

Entrepreneurship and Workplace Ethics

  • Pricing a job: price = direct cost + overhead + profit margin; a 20-30 % gross margin is typical for a small plumbing service.

  • GST registration is required above the turnover threshold set by the GST law; a plumber issuing a proper invoice builds trust and repeat business.

  • Quotation must state scope, exclusions, materials brand, warranty period, payment terms, and validity date.

  • Warranty practice: 12 months on workmanship, manufacturer warranty on materials; state both separately in writing.

  • Cash-flow rule: collect a 30-50 % advance on materials for a new customer, and bill progress payments at agreed milestones.

  • Ethics: never quote for a part that is not needed, disclose the material grade used, and return unused material or credit it to the customer.

  • Customer complaint handling: listen, acknowledge, inspect, fix within an agreed time, and record the outcome.

  • Business records: keep purchase bills, wage slips, and job invoices for the period required by tax law; they are also the basis for a loan application.

Quick reference

Practical Trade Work and Project Assessment

  • Assessment marking is typically split: practical work 60-70 %, viva/record 15-20 %, project report 15-20 %; confirm the split with the school's scheme.

  • A project report needs: title, objective, tools and materials list, procedure, observations, result, and a labelled sketch or photograph of the finished work.

  • A practical job is judged on: dimensional accuracy (within 2 mm), joint tightness under test pressure, neatness, tool care, and safe working.

  • Pressure test record for a project: fill, vent air, pressurise to 1.5 times working pressure, hold 1 hour, record start and end gauge readings.

  • Viva questions usually cover tool names, pipe sizes, joint methods, and the reason for a chosen gradient or trap seal.

  • Time discipline: a practical exam task is usually allotted 2-3 hours; plan cutting, joining, and testing within that window.

  • Housekeeping is marked: clear swarf, cap open pipe ends, and leave the work area dry and clean.

  • Safety observation during practical exam: PPE worn, correct lifting, no open flame near solvent cement, and electrical tools checked before use.