- Adoption of model code
- A model code becomes enforceable only when a jurisdiction adopts it by ordinance, specifying the edition, effective date, and any local amendments that modify the model text.
- Referenced standards
- Technical standards such as NFPA 13 or ASCE 7 are enforceable only through the code's reference, including the specific edition year cited in the adopted code.
- Board of appeals
- A local body authorized by ordinance to hear appeals of code official interpretations and denials; appeals must be filed within the time limit stated in the administrative provisions.
- Alternate materials approval
- The code official may approve materials or methods not specifically prescribed when evidence shows equivalence in quality, strength, fire resistance, and safety to the code requirement.
- Plan review order
- Review proceeds from submittal completeness to use and zoning, occupancy and construction type, egress, fire protection, structural, accessibility, and energy, with each stage documented.
- Allowable area calculation
- Base area from the occupancy and construction type table, adjusted for frontage increase, then multiplied by the sprinkler increase; the result is compared with actual building area.
- Egress capacity formula
- Required width equals occupant load multiplied by the capacity factor for the component, such as 0.2 inch per occupant for level surfaces and 0.15 for stairs.
- Deferred submittals
- Portions of the design approved for later submission, such as truss shop drawings, are listed on the permit and tracked to ensure review before the related inspection.
- Special inspections statement
- A statement of special inspections identifies the structural tests and inspections required by Chapter 17 and the approved agencies responsible for performing and reporting them.
- Correction notice content
- A written notice identifies the code section violated, the observed condition, the required correction, and the reinspection procedure, forming the record for enforcement.
- Stop-work order
- An official order halting work performed without a permit, contrary to approved plans, or creating an unsafe condition; it remains until the official confirms correction.
- Certificate of occupancy
- Issued after final inspections confirm the building complies with approved plans and code; a temporary certificate may allow occupancy with defined conditions and an expiration date.
- Seismic design category
- A classification from mapped ground motion, site class, and risk category that determines structural detailing, irregularity review, and special inspection requirements.
- Risk category
- An occupancy-based classification from I to IV reflecting consequence of failure; higher categories increase design loads and importance factors for structural safety.
- High-rise threshold
- A building with an occupied floor more than 75 feet above the lowest fire department access level triggers additional requirements including sprinklers, standpipes, and a fire command center.
- Fire-resistance rating
- The time in hours an assembly resists fire exposure, determined by listed designs or tested assemblies, and applied to structural members, shafts, exits, and separations.
- Occupancy group classification
- Assignment of a building or space to an IBC group such as A, B, E, F, H, I, M, R, S, or U based on the use and hazard, which controls code requirements.
- Construction type
- A classification from Type I to Type V describing combustibility and fire resistance of structural elements; Types I and II are noncombustible and Type V is combustible.
- Incidental use separation
- Certain subordinate uses listed in the incidental use table must be separated from the main occupancy by rated assemblies or treated as separate occupancies for code compliance.
- Separated versus nonseparated occupancy
- Mixed uses may be separated by rated assemblies with individual area calculations, or treated as nonseparated with the most restrictive requirements applied throughout.
- Occupant load factor
- A square-foot-per-occupant value from the code table, applied to floor area to compute occupant load, which then determines egress width and fixture counts.
- Exit remoteness
- Required exits must be separated by a distance related to the building diagonal or a stated minimum so that a single fire event cannot block all egress paths.
- Travel distance
- The measured distance along the natural path from the most remote point to an exit, limited by occupancy and sprinkler protection under the code's egress provisions.
- Accessible route
- A continuous unobstructed path connecting accessible entrances, spaces, and elements, meeting prescribed width, slope, surface, and turning space requirements.
- Conflict of interest disclosure
- Officials must disclose financial interests in projects and recuse from review or inspection decisions where impartiality could reasonably be questioned.
- Notice of violation
- A written notice stating the code violation, required corrective action, and compliance deadline, providing the due process basis for further enforcement if uncorrected.
- Qualified immunity
- Protection from liability for discretionary official acts performed in good faith within authority; ministerial acts performed negligently may not receive the same protection.
- Records disclosure
- Permit and inspection records are generally public under state records law, but trade secrets and security-sensitive details may be exempt and are handled per jurisdiction policy.
- IEBC work area method
- A compliance approach classifying alterations by work area as Level 1, 2, or 3, with increasing upgrade requirements as the scope affects egress and structural elements.
- Change of occupancy
- A new use requiring compliance with the code for the new occupancy, with existing-building allowances determined by the selected IEBC compliance method.
- Unsafe structure declaration
- A finding that a building is structurally deficient, a fire hazard, or dangerous to life, authorizing the official to order repair, vacation, or demolition after notice and hearing.
- IPMC maintenance standard
- A property maintenance code establishing minimum standards for structural integrity, sanitation, weathertightness, and life-safety systems in existing buildings.