RBSE SS Voc Micro-Irrigation Tec study materials
RBSE SS Voc Micro-Irrigation Tec study resources

RBSE SS Voc Micro-Irrigation Tec cheat sheet

RBSE SS Voc Micro-Irrigation Tec · Keep the key ideas within reach.

Quick reference

Fundamentals of Irrigation and Soil-Water-Plant Relationships

  • Field capacity (FC) is the water content retained after free drainage, typically at soil matric potential of −10 to −33 kPa; permanent wilting point (PWP) is near −1500 kPa; available water capacity (AWC) = FC − PWP.

  • Management allowed depletion (MAD) is the fraction of AWC that may be used before irrigation; for most field crops MAD is 0.5, for sensitive horticultural crops 0.25–0.4.

  • Irrigation interval (days) ≈ (AWC × root zone depth × MAD) ÷ crop evapotranspiration (ETc); all depths in the same units.

  • ETc = Kc × ETo, where ETo is reference evapotranspiration and Kc is the crop coefficient that changes by growth stage (initial, development, mid-season, late season).

  • Infiltration rate must exceed application rate; if application rate exceeds the soil's basic infiltration rate, runoff and ponding occur.

  • Crop water use peaks at flowering/fruit set; water stress then causes the largest yield loss, while stress at ripening mainly affects quality.

  • Soil texture controls AWC: sandy soils hold about 60–100 mm/m, loams about 140–190 mm/m, and clays about 180–220 mm/m of available water.

  • Root zone depth increases through the season; design emitter depth and wetting pattern for the mature root system, not the seedling stage.

Quick reference

Micro-Irrigation Systems: Types, Components and Layout

  • Drip/trickle applies water at low pressure (typically 0.5–2.0 bar at the emitter) directly to the root zone; micro-sprinklers and mini-sprinklers spray water over a wetted area around each plant.

  • A drip system head works sequence: water source → pump → check valve → fertilizer injection point → filters → pressure regulator → main line → sub-main → lateral with emitters.

  • Filters are placed downstream of the injection point so that fertigation residues are filtered before reaching laterals.

  • A check valve and vacuum breaker at the injection point prevent backflow of fertilizer into the water source and prevent suction of soil into the system at shutdown.

  • Laterals are usually 12–20 mm polyethylene; emitters are inline (built into the tubing at fixed spacing) or online (punched into the lateral at chosen spacing).

  • A flush valve at the end of each lateral or sub-main allows periodic removal of sediment; end caps or flush manifolds are mandatory on every lateral.

  • Pressure-compensating (PC) emitters maintain rated flow over a pressure range (often 0.5–4.0 bar) and allow longer laterals and level or undulating terrain.

  • Air valves at high points release trapped air that would otherwise cause uneven flow and water hammer; non-return valves protect the pump from backflow.

Quick reference

Drip Irrigation Design, Installation and Operation

  • Emitter flow rate q (L/h) and spacing determine application rate: application rate (mm/h) = (q × number of emitters per m² ) ÷ 1, i.e. q ÷ (emitter spacing in m × lateral spacing in m).

  • Wetted percentage Pw = (wetted width × number of laterals per bed or row) ÷ total area × 100; design Pw is typically 30–60% for row crops and 60–90% for orchards.

  • Christiansen uniformity CU and distribution uniformity DU measure emission uniformity; DU = (average of lowest quarter of emitter flows) ÷ (mean emitter flow) × 100.

  • Emission uniformity EU = 100 × (1 − 1.27 × CV ÷ √n), where CV is manufacturer's coefficient of variation and n is emitters per plant; target EU ≥ 90% for good design.

  • Lateral length is limited by allowable pressure variation, commonly ±10% of nominal emitter pressure, or by manufacturer's maximum lateral length tables for PC and non-PC emitters.

  • Friction head loss in laterals and sub-mains is calculated with the Hazen-Williams or Darcy-Weisbach equations; multiple outlet (Christiansen) reduction factor F reduces the total loss.

  • Total design head = emitter operating pressure + filter loss + valve/fitting loss + friction loss in laterals, sub-mains and main + elevation difference + safety margin.

  • Fertigation and chemical treatment require flushing with clean water afterwards; chlorine is used at low concentration for organic clogging and acid for carbonate scaling.

Quick reference

Sprinkler Irrigation Design, Installation and Operation

  • Sprinkler application rate (mm/h) = (sprinkler discharge in L/h) ÷ (sprinkler spacing in m × lateral spacing in m); it must not exceed the soil's basic infiltration rate.

  • Sprinkler spacing along the lateral should not exceed 60% of the wetted diameter, and lateral spacing should not exceed 65% of wetted diameter for acceptable uniformity.

  • Operating pressure must be within the manufacturer's range; low pressure reduces wetted diameter and uniformity, high pressure increases drift, evaporation loss and droplet breakup.

  • Uniformity is described by Christiansen's coefficient of uniformity (CU), with CU ≥ 84% generally acceptable for field crops and higher values for horticulture.

  • Wind above about 3 m/s distorts the pattern; sprinkler spacing and orientation should be adjusted, and night irrigation reduces wind drift and evaporation losses.

  • Sprinkler systems are classified as solid set, semi-portable, portable, travelling gun, boom, or centre-pivot/linear-move; selection depends on field shape, crop and labour.

  • Impact and rotating sprinklers need a minimum pressure to turn; gear-drive and turbo sprinklers operate at lower pressure and are more energy-efficient.

  • Pump duty point must match system head plus flow; a pump curve intersecting the system curve too far left or right of design causes poor uniformity and possible cavitation.

Quick reference

Pump Sets, Filtration, Fertigation and Automation

  • Pump total head = static lift + friction losses in suction and delivery + velocity head + operating pressure at the outlet; flow and head define the duty point on the pump curve.

  • Centrifugal pumps are used for surface water; submersible pumps for bore wells; the suction lift for a centrifugal pump should not exceed about 7 m at sea level.

  • Cavitation occurs when net positive suction head available (NPSHa) falls below NPSH required by the pump; symptoms are noise, vibration and reduced flow.

  • Sand media filters remove organic and inorganic particles down to about 40–50 microns; screen filters typically 100–200 mesh (about 75–150 microns); disc filters 100–400 microns depending on rating.

  • Filtration selection depends on water source: canal/lake water needs media plus screen; clean bore water may need only screen or disc filters.

  • Venturi injectors and diaphragm/positive-displacement pumps are common fertigation devices; injection rate must be matched to irrigation flow and the fertilizer must be fully soluble.

  • Fertigation schedule: inject fertilizer in the middle third of the irrigation cycle, then flush with clean water for at least 10–15 minutes to prevent emitter clogging.

  • Automation uses controllers, solenoid valves, pressure switches and soil moisture or weather sensors; a rain sensor or float switch protects the pump and prevents overflow.

Quick reference

Maintenance, Troubleshooting and Repair of Micro-Irrigation Systems

  • Routine maintenance schedule: flush laterals monthly or more often, clean filters when pressure differential across the filter exceeds about 0.5 bar, and check emitters each season.

  • Emitter clogging causes are physical (sand, silt), chemical (calcium carbonate, iron) and biological (algae, bacterial slime); each requires a different treatment.

  • Chlorination for organic clogging: inject chlorine to maintain 1–2 ppm free residual at the end of the lateral for 30–60 minutes, then flush.

  • Acid treatment for carbonate scaling: dilute hydrochloric or sulfuric acid to bring irrigation water pH to about 4.0–5.0, circulate, then flush thoroughly; acid is corrosive and requires PPE.

  • A quick field check for clogging is to compare emitter flows at the beginning, middle and end of a lateral; a variation above 10% indicates a problem.

  • Pressure gauge readings at the head and at the far end of the main reveal filter blockage, leaks, or a worn pump impeller.

  • Leaks and broken laterals are repaired with barbed connectors, goof plugs or compression fittings; the repair must not reduce the internal diameter enough to change flow.

  • Record-keeping of flush dates, chemical treatments, filter cleaning and pump servicing allows fault tracing and supports warranty claims.

Quick reference

Water Source, Water Quality and Environmental Considerations

  • Water quality for drip is assessed by pH, electrical conductivity (EC), total suspended solids, hardness, iron, manganese and bacterial load.

  • EC above about 1 dS/m may cause salinity stress in sensitive crops; leaching requirement (LR) = ECw ÷ (5 × ECe − ECw) for a target soil ECe.

  • Iron above 0.5 ppm and manganese above 0.1 ppm promote bacterial slime and chemical precipitation in drip lines and require aeration or oxidation treatment.

  • Hydrogen sulfide, high bicarbonate and high calcium cause scaling; water with high carbonate hardness needs acidification before fertigation.

  • Water source options include bore wells, canals, farm ponds, check dams, and treated wastewater; each has different filtration and permitting requirements.

  • Environmental safeguards: avoid over-irrigation that leaches nutrients into groundwater, maintain buffer strips near water bodies, and dispose of filter backwash and chemical rinses responsibly.

  • Soil salinity monitoring with EC of saturated paste extract or soil EC sensors guides leaching and crop choice; drip irrigation can maintain a leached zone near emitters.

  • Rainwater harvesting structures and storage tanks reduce dependence on groundwater and improve water availability during peak demand.

Quick reference

Entrepreneurship, Costing, Government Schemes and Customer Service

  • Project cost for a drip system includes head works, pump, filters, fertigation unit, main/sub-main/laterals, emitters, valves, fittings, installation and labour.

  • Simple payback period (years) = total investment ÷ annual net benefit, where annual net benefit = additional income from yield/quality gain + water and energy savings − maintenance cost.

  • Benefit-cost ratio (BCR) = present value of benefits ÷ present value of costs; a BCR above 1 indicates an economically viable investment.

  • Government support in India for micro-irrigation is delivered mainly through the Pradhan Mantri Krishi Sinchayee Yojana (PMKSY) - Per Drop More Crop component, with subsidy shared between centre and state.

  • Typical subsidy norms under PMKSY provide a percentage of the system cost to small and marginal farmers that is higher than for other farmers, subject to per-hectare ceilings.

  • A complete customer quotation should list area, crop, spacing, emitter type, flow rate, head, pipe sizes, filters, fertigation unit, installation, warranty and after-sales service.

  • After-sales service includes system commissioning, operator training, a maintenance calendar, spare parts availability and a complaint response time.

  • Entrepreneurship requires registration (GST, Udyam), a technical team, service vehicles, and demonstration plots that build farmer confidence.

Quick reference

Occupational Safety, Health and Workplace Practices

  • Personal protective equipment for fertigation and chemical treatment: chemical-resistant gloves, goggles or face shield, apron, boots and respirator when handling acids or chlorine.

  • Always add acid to water, never water to acid, to avoid violent exothermic spattering.

  • Store fertilizers and chemicals in labelled, locked, ventilated areas away from water sources, feed and livestock, with a spill kit and material safety data sheets available.

  • Electrical safety: pump panels must be earthed, fitted with an MCB/ELCB, and only opened by authorised electricians; wet hands and flooded pump houses are high-risk.

  • Before servicing a pump or opening a filter, isolate power, close valves and release residual pressure; never open a filter housing under pressure.

  • Excavation for pipelines requires locating underground cables and utilities first; trenches deeper than 1.5 m need shoring to prevent collapse.

  • Heat stress prevention: schedule field work in cooler hours, provide drinking water and shade, and train workers to recognise heat exhaustion symptoms.

  • First aid for acid or chlorine splash: flush with copious clean water for at least 15 minutes and seek medical help; keep an eyewash station near the chemical store.

Quick reference

Practical Skills, Field Demonstration and Project Work

  • Field measurement of emitter flow: collect water from a known number of emitters for a measured time (e.g. 60 s) and convert to L/h; sample at head, middle and tail of the lateral.

  • Pressure measurement with a calibrated gauge at the first and last emitter of a lateral gives the actual pressure variation, which should be within ±10% of design.

  • Wetted front and wetted diameter are measured by excavating a soil profile or observing the surface wetting pattern after a known irrigation duration.

  • A field demonstration layout should show water source, head works, main, sub-main, laterals, emitters, flush valves and the area served, to scale.

  • Project work should include a site survey (area, slope, soil, water source, crop), a design calculation sheet, a bill of materials and a cost estimate.

  • Commissioning checks: flush all lines before installing emitters, pressure-test the network, verify flow at the farthest point, and record baseline readings.

  • Soil infiltration can be checked with a double-ring infiltrometer or a simple cylinder test to confirm the application rate is safe.

  • Training demonstrations should compare uniform versus non-uniform emission using catch cans or flow measurements, making the concept of DU visible to farmers.