RBSE SS Voc Micro-Irrigation Tec flashcards
RBSE SS Voc Micro-Irrigation Tec · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Available water capacity
- The water held between field capacity and permanent wilting point in the root zone. Calculated as field capacity minus permanent wilting point, expressed in mm per metre of soil depth.
- Management allowed depletion
- The fraction of available water a crop may use before irrigation is scheduled. Commonly 0.5 for field crops and 0.25 to 0.4 for sensitive horticultural crops.
- Crop evapotranspiration
- Water lost from the field through soil evaporation and plant transpiration. Estimated as the crop coefficient Kc multiplied by reference evapotranspiration ETo.
- Basic infiltration rate
- The steady rate at which a soil accepts water. Application rate of any irrigation system must stay below this value to prevent runoff and ponding.
- Pressure-compensating emitter
- An emitter that maintains a nearly constant rated flow over a wide pressure range, typically 0.5 to 4 bar, allowing long laterals and uneven terrain.
- Fertilizer injection point
- The location in the head works where fertilizer is introduced. It must be upstream of the filters and downstream of a check valve to prevent backflow.
- Flush valve
- A valve or removable end cap at the end of a lateral or sub-main that allows sediment and debris to be discharged periodically, protecting emitters from clogging.
- Inline versus online emitters
- Inline emitters are built into the tubing at fixed factory spacing; online emitters are punched into a plain lateral at any chosen spacing during installation.
- Emission uniformity
- A measure of how evenly emitters discharge water, calculated from manufacturer's coefficient of variation and number of emitters per plant. Target is 90 percent or higher.
- Distribution uniformity
- The ratio of the average flow of the lowest quarter of emitters to the mean emitter flow, multiplied by 100. It reflects real field performance.
- Wetted percentage
- The proportion of the field surface wetted by the drip system, calculated from wetted width and lateral spacing. Typically 30 to 60 percent for row crops.
- Allowable pressure variation
- The permitted difference in pressure along a lateral, commonly plus or minus 10 percent of nominal emitter pressure, which limits maximum lateral length.
- Sprinkler application rate
- Sprinkler discharge in litres per hour divided by the product of sprinkler spacing and lateral spacing in square metres. It must not exceed soil infiltration rate.
- Christiansen uniformity coefficient
- A sprinkler uniformity measure based on the sum of absolute deviations from mean catch depth. Values of 84 percent or above are generally acceptable for field crops.
- Wetted diameter rule
- Sprinkler spacing along the lateral should not exceed 60 percent of wetted diameter, and lateral spacing should not exceed 65 percent, for acceptable uniformity.
- Wind effect on sprinklers
- Wind above about 3 metres per second distorts the sprinkler pattern, reduces uniformity and increases drift loss. Night irrigation and closer spacing reduce the effect.
- Pump duty point
- The flow and head at which the pump curve intersects the system curve. It must match the design flow and pressure for uniform irrigation.
- Cavitation
- Formation and collapse of vapour bubbles when available net positive suction head falls below the pump requirement, causing noise, vibration, reduced flow and impeller damage.
- Sand media filter
- A pressure vessel containing graded sand that removes organic and inorganic particles down to roughly 40 to 50 microns. Cleaned by backwashing when pressure differential rises.
- Venturi injector
- A fertigation device that uses a pressure difference to draw fertilizer solution into the irrigation line. Simple and inexpensive, but causes a head loss.
- Fertigation flushing rule
- Inject fertilizer during the middle third of the irrigation cycle, then flush the lines with clean water for at least 10 to 15 minutes to prevent clogging.
- Filter pressure differential
- The difference in pressure across a filter. A rise of about 0.5 bar above the clean-filter baseline indicates the filter needs backwashing or cleaning.
- Chlorination for clogging
- Injection of chlorine to maintain 1 to 2 ppm free residual at the lateral end for 30 to 60 minutes to control organic and bacterial clogging, followed by flushing.
- Acid treatment for scaling
- Injection of dilute acid to bring irrigation water pH to about 4 to 5, dissolving calcium carbonate scale in emitters and laterals, followed by thorough flushing.
- Leaching requirement
- The fraction of irrigation water that must pass below the root zone to control salinity, estimated as ECw divided by five times ECe minus ECw.
- Iron and manganese in water
- Concentrations above about 0.5 ppm iron and 0.1 ppm manganese promote bacterial slime and precipitation, requiring oxidation or aeration before drip irrigation.
- Electrical conductivity of water
- A measure of dissolved salts. Values above about 1 dS/m may stress sensitive crops and require leaching, crop selection or blending with better water.
- Payback period
- Total investment divided by annual net benefit from yield gain, water and energy savings minus maintenance. It shows how many years the system takes to repay itself.
- PMKSY Per Drop More Crop
- The Indian government micro-irrigation subsidy component that shares system cost between centre and state, with higher support for small and marginal farmers.
- Benefit-cost ratio
- The present value of benefits divided by the present value of costs. A ratio above one indicates the micro-irrigation investment is economically viable.
- Acid dilution safety rule
- Always add acid slowly to water, never water to acid, because the reaction is strongly exothermic and can cause violent spattering and burns.
- Lockout before pump service
- Isolate electrical power, close valves and release residual pressure before servicing a pump, filter or valve to prevent electric shock and sudden water release.
- Emitter flow field check
- Collect water from a known number of emitters for a measured time at the head, middle and tail of a lateral and convert to litres per hour to detect clogging.