RBSE SS Voc Micro-Irrigation Tec: Pump Sets, Filtration, Fertigation and Automation

RBSE SS Voc Micro-Irrigation Tec · Work through your exam, one topic at a time.

All guide sections

Pump Sets, Filtration, Fertigation and Automation

What the exam tests

This domain tests total dynamic head, pump selection, filter operation, fertilizer injection and basic automation logic.

Core rules and concepts

  • Total dynamic head (TDH) = vertical lift + friction loss + operating pressure, all converted to metres. 1 bar ≈ 10.2 m of water head.
  • The pump must be selected at the duty point where its curve meets the system curve; a pump far from duty point may run hot, cavitate or waste energy.
  • Suction conditions matter: excessive suction lift or a blocked strainer can cause cavitation and low output.
  • Media filters require backwashing at a set pressure difference or time; screen filters require cleaning when the pressure drop rises.
  • Fertigation injects stock solution downstream of the filter and with backflow prevention. Injection rate is set from the nutrient concentration and irrigation flow.
  • Automation uses controllers, solenoid valves, pressure sensors and EC/pH sensors, but manual checks are still needed.

Worked example

Water level is 30 m below ground, the outlet is 2 m above ground, friction loss is 8 m, and the system needs 2 bar at the head. Lift = 30 + 2 = 32 m. Operating pressure = 2 × 10.2 ≈ 20.4 m. TDH = 32 + 8 + 20.4 = 60.4 m. The pump must deliver the design flow at about 60 m head. If a pump rated at 45 m is installed, the system will not reach the required pressure even if the flow looks adequate at the outlet.

Traps that cost marks

  • Adding pressure in bar directly to head in metres.
  • Ignoring friction loss in mains and submains.
  • Injecting fertilizer upstream of a filter without considering precipitation and backflow.
  • Backwashing a media filter with insufficient flow.
  • Trusting automation without checking EC, pH and pressure.