RBSE SS Voc Plumbing study materials
RBSE SS Voc Plumbing study resources

RBSE SS Voc Plumbing cheat sheet

RBSE SS Voc Plumbing · Keep the key ideas within reach.

Quick reference

Plumbing Tools

  • Pipe wrench: jaws grip and turn pipe; size is rated by the pipe diameter it fits (e.g., 350 mm wrench for 50 mm pipe). Always pull the handle toward you, not push.

  • Stillson (pipe) wrench teeth are directional - the jaw teeth point in the direction of rotation when the handle is pulled; reversing the grip gives poor bite.

  • Basin wrench: long, spring-loaded jaw reaches behind a lavatory bowl to loosen trap nuts where a normal wrench will not fit.

  • Flaring tool set: 45° flare for copper water lines; the cone is pressed into the tube end to form the flare, then the flare nut is tightened onto the fitting.

  • Tube cutter: score-and-snap wheel for copper; ream the inside burr after cutting or flow is reduced and turbulence/corrosion increases.

  • Threading: hand die stock with 15–50 mm dies cuts BSP/NPT external threads; apply cutting oil and reverse a quarter turn every full turn to break chips.

  • Level and plumb bob: check slope of drainage runs (typically 1:60 to 1:100 for 100 mm pipe) and verticality of stacks.

  • Pressure testing pump (hydrostatic tester): fills system with water and pressurises to check joints before concealment; gauge must be calibrated.

Quick reference

Materials and Safety Practices

  • GI (galvanised iron) pipe: mild steel with zinc coating; used for cold water and some drainage, joined by threaded fittings. Zinc resists corrosion but is attacked by acidic water.

  • uPVC: rigid unplasticised polyvinyl chloride for soil, waste, and vent; joined by solvent cement. CPVC handles hot water up to about 80–90 °C.

  • PPR (polypropylene random): heat-fusion socket welded; used for hot and cold water supply; fusion joint is stronger than the pipe wall.

  • Copper: Type L for domestic water, Type K for underground; joined by soldering (lead-free solder), brazing, or press fittings.

  • Cast iron soil pipe: joined by lead-and-oakum caulking (traditional) or no-hub couplings; heavy, quiet, and fire-resistant.

  • PPE for plumbing: safety glasses when cutting/threading, gloves for solvent cement and caustic drain chemicals, respirator for PVC cement vapours in confined spaces, steel-toe boots.

  • Solvent cement is flammable and gives off VOCs - use only with ventilation; never near open flame.

  • Confined-space entry (manholes, sumps): test for oxygen (19.5–23.5%), LEL, H2S, CO before entry; attendant outside; harness and tripod.

Quick reference

Water Supply Systems and Pipe Fitting

  • Direct supply: mains pressure feeds fixtures directly; indirect supply: mains fills an overhead/underground tank, then gravity or a pump feeds fixtures.

  • Minimum residual pressure at a fixture: typically 0.5–1.0 bar (5–10 m head) for satisfactory flow; below this, a booster pump is used.

  • Pipe sizing uses fixture units and equivalent length; velocity in supply pipes should stay below about 1.5–2.0 m/s to limit noise and erosion.

  • Water hammer: caused by sudden valve closure; arrested by an air chamber or a mechanical shock absorber installed near the fixture.

  • Air lock in a gravity line is cleared by venting at the highest point or by re-priming; a continuous upward slope prevents trapping air.

  • Cross-connection control: a backflow preventer (air gap, RPZ, or double check valve) is required wherever a non-potable source could reverse-flow into the potable line.

  • Fitting take-off: 90° elbow changes direction, tee branches, reducer changes diameter, union allows disassembly, coupling joins two plain ends.

  • Pressure test of supply pipework: fill, purge air, pressurise to 1.5× working pressure (or code-specified value) and hold; no drop means sound joints.

Quick reference

Sanitary Fixtures

  • Water closet (WC): wash-down or siphon type; trapway water seal must be 50 mm minimum to stop sewer gas.

  • Wash basin (lavatory): supplied through a 15 mm branch; waste 32–40 mm; overflow channel must drain into the trap, not outside it.

  • Floor trap (nahani trap): 50–75 mm trap with 50 mm water seal; used where a floor drain is needed and a P-trap cannot be fitted below.

  • Fixture unit (FU) values: WC = 4–6 FU, wash basin = 1 FU, sink = 2 FU, bath = 2 FU, floor trap = 1 FU (values vary by code; check local schedule).

  • Flush cistern: float valve (ball valve) refills; flush valve or siphon flushes; a running cistern usually means a worn washer or mis-set float.

  • Bidet, urinal, and drinking fountain each need their own trap and backflow protection; urinals use flushometer or cistern flush.

  • Accessibility: grab bars, 750–800 mm WC seat height for ambulant users, and lever handles; clear floor space in front of fixtures.

  • Fixture spacing: minimum 450 mm from a WC centre to a side wall; 150 mm clearance from fixture edge to adjacent wall for basins.

Quick reference

Drainage and Sewerage Systems

  • Two-pipe system: soil (WC) and waste (sinks, basins) discharge into separate stacks; one-pipe system combines them with a single stack and vent.

  • Stack vent (soil vent pipe) continues full bore above the roof to relieve pressure and let sewer gas escape above the building.

  • Trap seal: 50 mm water seal prevents sewer gas entry; a trap is required at every fixture and floor drain.

  • Vent pipe sizing: a 100 mm stack normally needs a 50–75 mm vent; relief vents are needed on stacks taller than about 10 storeys.

  • Self-siphonage is prevented by venting; induced siphonage is prevented by anti-siphon traps or a common vent.

  • Drain slope: 1:60 to 1:100 for 100 mm pipe; too flat causes solids deposition, too steep leaves liquids behind.

  • Inspection chamber (manhole): provided at changes of direction, at junctions, and at intervals of 45–90 m on straight runs.

  • Grease trap: intercepts kitchen fats before the sewer; sized by flow rate and retention time (typically 30 minutes).

Quick reference

Plumbing Drawings

  • Plan view: top-down layout showing fixture positions, pipe routes, and dimensions; the scale is stated in the title block (e.g., 1:50).

  • Isometric (isometric riser diagram): three-dimensional single-line drawing showing pipe sizes, gradients, and fittings; used for supply and drainage layouts.

  • Section/elevation: shows vertical pipe runs, invert levels, and stack heights; invert level = bottom inside of pipe.

  • Symbols: circle with cross = floor drain; triangle = vent; gate valve = bow-tie; check valve = bow-tie with arrow; dashed line = concealed pipe.

  • Line types: solid thick = visible pipe; dashed = concealed or below slab; centre line = axis of symmetry or pipe centre.

  • Title block contains project name, drawing number, scale, date, revision, and the designer's name; revisions are clouded and tagged.

  • Bill of quantities is read from drawings: count fixtures, measure pipe runs by size, and add fittings per junction.

  • Levels are given in metres above datum (e.g., +2.850); invert levels drop by the pipe gradient along the run.

Quick reference

Estimating and Costing

  • Quantity take-off: measure pipe by centre-line length per diameter, count fittings and fixtures, and add wastage (typically 5–10% on pipe, 2–5% on fittings).

  • Rate analysis builds a unit rate from material cost + labour cost + plant + overheads + contractor profit.

  • Labour constants: a plumber plus helper can install roughly 20–30 m of 15–25 mm GI pipe per day in normal conditions; use published constants for tendering.

  • Contingency is usually 5–10% of the estimated cost; escalation is added for projects longer than one year.

  • Bill of quantities (BOQ): item description, unit (m, no., kg), quantity, rate, and amount; measured items must match the drawing.

  • Cost of a joint includes the fitting, solder/cement, and labour time; a threaded GI joint is costlier in labour than a solvent-welded uPVC joint.

  • Value engineering: compare life-cycle cost, not just first cost - PPR and CPVC cost more initially but last longer than GI in hard water.

  • Measurement rules: pipe length is measured along the centre line and does not deduct for fittings under a stated size (commonly below 50 mm).

Quick reference

Maintenance, Repair and Leak Detection

  • Leak at a threaded joint: isolate, drain, unscrew, clean threads, apply PTFE tape or jointing compound, and re-tighten; do not over-tighten (cracks the fitting).

  • Leak at a solvent-welded joint: cut out the fitting and re-make with a coupling; solvent joints cannot be unscrewed.

  • Pin-hole leak in copper: cut out the damaged section and splice with two couplings, or use a repair clamp for a temporary fix.

  • Water meter test for hidden leaks: shut all fixtures and watch the meter; a moving dial indicates a leak, often a running cistern or a buried line.

  • Dye test: add dye to the cistern or trap and check downstream; colour appearing at the wrong place locates a cross-connection or a broken seal.

  • Acoustic leak detection: listen with a stethoscope or ground microphone at night when background noise is low; hiss = pressure leak, gurgle = drain.

  • Frozen pipe: thaw with warm air or a hot towel from the open end toward the freeze; never use an open flame on a pressurised line.

  • Preventive maintenance schedule: inspect traps and vents annually, descale hot-water cylinders, test backflow preventers yearly, and check pump seals.

Quick reference

Plumbing Code

  • Every fixture must be trapped and vented; a trap may not be double-trapped or have two fixtures on one trap (except where code allows a combination fixture).

  • Trap seal depth: 50 mm minimum, 100 mm maximum; deeper seals trap air and drain slowly.

  • No vertical drop greater than 1.5 m into a trap arm without a vent; the trap arm length is limited (commonly 1.5–2.4 m depending on pipe size).

  • Water supply pipe may not pass through a sewer or a vent; minimum horizontal separation of 300 mm between water and drain lines, with water above the drain.

  • Backflow protection is mandatory at any connection to a boiler, irrigation line, or non-potable supply.

  • Vent terminal must be at least 150 mm above the roof surface and 3 m from an operable window or air intake.

  • Cleanouts are required at the base of each stack, at changes of direction over 45°, and at intervals not exceeding 15 m in horizontal drains.

  • Fixtures must be accessible for repair; concealed traps need an access panel.

Quick reference

Environmental and Occupational Health Requirements

  • Lead in drinking water: lead pipes and lead solder are prohibited; test water where lead service lines remain and flush before use.

  • Legionella risk: hot water should be stored at 60 °C or above and distributed at 50 °C or above; dead legs and lukewarm ranges promote growth.

  • Asbestos cement pipe: do not cut or abrade dry; wet the material, use respiratory protection, and dispose as hazardous waste.

  • Noise: supply velocity below 1.5 m/s and drainage stacks with acoustic lagging keep noise within acceptable limits in dwellings.

  • Waste segregation on site: PVC offcuts, copper, and packaging are separated; solvent cement residues are hazardous waste.

  • Manual handling: two-person lift for cast iron pipe and cylinders; use a pipe trolley; keep the load close to the body.

  • Electrical safety: use 110 V site tools or RCD protection; do not work on a pump or immersion heater without isolating and locking off.

  • First aid for chemical splash: irrigate eyes with clean water for 15 minutes and seek medical help; keep the safety data sheet available.

Quick reference

Practical / Workshop Skills Assessment

  • Pipe cutting: mark square with a square or wrap-around, cut, then file/ream the burr; a square cut is the basis of a leak-free joint.

  • Threading sequence: cut to length, ream, chamfer, clamp in a vice, oil the die, cut the thread, test-fit the fitting by hand, then tighten with a wrench.

  • Solvent welding: dry-fit, clean with primer, apply cement to both surfaces, push and twist a quarter turn, hold 30 seconds, and allow full cure before pressure testing.

  • Soldering copper: clean to bright metal, apply flux, heat the fitting (not the solder), and feed lead-free solder into the joint until a capillary ring forms.

  • Bending copper: anneal by heating to dull red and cooling, then bend with a spring or bender to avoid flattening the tube.

  • Pressure test procedure: cap open ends, fill slowly, vent air, pressurise, hold, inspect every joint, then release and record the result.

  • Level and gradient check: use a spirit level with a wedge or a laser; verify the fall with a straight edge and rule over a known length.

  • Tool care: wipe pipe wrench teeth, oil the adjusting nut, store dies in oil, and replace a cracked hammer handle - never weld it.