Mistake 1

Choosing fuse wire or MCB rating by matching the appliance's wattage label instead of computing current as I = P/V and then applying the derating and surge rules; for example, fitting a 16 A fuse on a 2000 W geyser at 230 V without checking that the steady current is about 8.7 A and that the protective device must still coordinate with the cable's current-carrying capacity.

Candidates memorise 'geyser = 16 A' style pairings from shop practice and skip the calculation, and they confuse the appliance's rated current with the circuit's design current; many also forget that resistive loads have no starting surge while motor loads do.

What to do instead

Practise a fixed three-step routine for every load: compute I = P/(V × power factor), select cable from a current-rating table with derating for ambient temperature and grouping, then select the fuse or MCB so that Ib ≤ In ≤ Iz. Do ten mixed drills covering resistive, inductive and motor loads until the routine is automatic.

Mistake 2

Reporting a reading without stating the instrument, range and condition, for example writing 'resistance is 40' when the multimeter was on the 200 Ω range showing 40 Ω, or recording an insulation resistance of '5' without the megohmmeter's test voltage and the fact that the appliance was disconnected.

Candidates treat the number on the display as the answer and do not realise that range, test voltage, and circuit state change what the number means; this is common where the same display digits appear on different ranges.

What to do instead

Adopt a fixed recording format in the workshop record book: quantity, instrument and model, range or test voltage, circuit condition (isolated, disconnected, load connected), ambient condition, and reading with unit. Before writing any value, say aloud which range is selected and what the meter would show if the component were open or shorted.

Mistake 3

Testing a heating appliance's element with a continuity buzzer only and declaring it good, without measuring the actual resistance and comparing it with the value expected from the rating plate, and without an insulation resistance test to earth.

A continuity tester beeps for any low-resistance path, so a partially shorted or heavily drifted element still passes; candidates also skip insulation testing because it needs a megohmmeter and isolation discipline they are unsure of.

What to do instead

For every element, compute the expected cold resistance from R = V²/P (for example, a 1000 W, 230 V element is about 53 Ω), measure it, and accept only within a stated tolerance. Then test insulation resistance from live parts to the earthed body at the specified test voltage and record both results.

Mistake 4

Treating a tripping MCB or a blown fuse as the fault itself, resetting or replacing it and returning the appliance to the customer without finding the leakage or overload that caused it.

The protective device is the visible symptom, and candidates under time pressure want the quick win; they also lack a structured method for separating overload from earth leakage from a short circuit.

What to do instead

Apply a decision tree: measure insulation resistance to earth first, then check load current against rating, then inspect for mechanical damage and moisture. Replace a protective device only after the cause is identified and documented, and state in the job card what was found and what was corrected.

Mistake 5

Diagnosing a mixer-grinder or washing machine motor fault without first checking the supply, plug, cord, switch and capacitor, and without separating the mechanical load (jammed jar, seized bearing, blocked pump) from the electrical circuit.

Candidates jump to the motor because it is the expensive, interesting component, and they do not systematically split the appliance into supply, control, drive and load sections; a failed capacitor or a worn carbon brush then gets misread as a burnt winding.

What to do instead

Use a written half-split checklist for every motor appliance: supply voltage at socket, continuity of cord and plug, switch operation, capacitor value measured against its marking, brush length, winding resistance, then mechanical freedom of the load. Record which section was eliminated at each step so the diagnosis is auditable.

Mistake 6

Handling refrigerant and the sealed system casually: venting refrigerant to atmosphere while opening a joint, brazing without nitrogen purging or a heat shield, and charging by guesswork instead of weighing or using superheat/subcooling.

Candidates learn charging from informal shop habits and do not connect the environmental, safety and performance consequences to the procedure; they also underestimate how moisture and air in the circuit cause repeat failures.

What to do instead

Follow a fixed sequence: recover refrigerant into a cylinder, replace the filter drier whenever the circuit is opened, purge with nitrogen while brazing, evacuate to the specified vacuum and hold it, then charge by weight from the nameplate or set charge by superheat or subcooling. Log vacuum, hold time and charge weight on every job.

Mistake 7

Writing an inverter or LED appliance repair off as 'board faulty, replace board' without checking the input supply, DC bus, output waveform, feedback sensor or the load, and without testing the replacement board's connections before power-up.

Fault codes and sealed boards feel opaque, so candidates substitute parts instead of measuring; they also lack practice in safe live testing of low-voltage control sections and in reading the schematic.

What to do instead

Work the chain in order: mains input and fuse, DC bus voltage, gate drive or switching device, output stage, sensors, then the control supply. Compare measured DC bus and output values with the schematic's stated test points, and prove the load separately on a known-good source before fitting any replacement board.

Mistake 8

Describing a repair to a customer in technical shorthand ('IC burnt, board changed, capacitor weak') without a clear statement of what was wrong, what was done, what it costs and what the customer should do next, and without a written estimate before starting work.

Candidates rehearse only the bench skills and never practise the conversation; they fear a detailed explanation invites argument, so they give vague answers that later cause disputes over bills and repeat complaints.

What to do instead

Practise a four-line script for every job: fault found, work done, parts used, advice to the customer, followed by the price with labour and parts separated. Give the estimate in writing and get approval before work, and rehearse the script in role-play with a partner acting as an unhappy customer.

Mistake 9

Treating personal protective equipment and isolation as a formality: working live on a heating appliance because it is 'only 230 V', wearing no eye protection when opening a pressurised or spring-loaded assembly, and not locking off or tagging the supply before working on a washing machine or pump.

Familiarity breeds contempt, and candidates have often seen experienced technicians work live without incident; they also do not connect damp floors, earthed bodies and single-phase shock to a realistic fatality risk.

What to do instead

Make isolation and proving dead a physical ritual: switch off, lock and tag, test the tester on a known live source, prove the circuit dead, then re-prove the tester. Wear the specified PPE for each task and state the hazard aloud before starting; treat any live testing as requiring a second person and insulated tools.

Mistake 10

In the employability and entrepreneurship section, giving generic answers about 'hard work and honesty' instead of concrete, examinable content such as costing a job (material, labour, overhead, margin), GST and invoice essentials, warranty terms, or the specific communication steps for handling a complaint.

Candidates revise only the technical domains because those feel like the real subject, and they underestimate how many marks come from short, factual questions on costing, documentation and customer handling.

What to do instead

Build a one-page revision sheet for each non-technical topic with numbers and steps: a worked costing example, a sample invoice's mandatory fields, a five-step complaint-handling sequence, and the difference between warranty and guarantee. Answer past-style questions in bullet points with the specific term first, then the explanation.