- Ohm's law
- Voltage equals current multiplied by resistance (V = I × R). It is used to calculate expected current, voltage drop, and element resistance in domestic appliance circuits.
- RCCB 30 mA
- A residual current device that trips when leakage to earth exceeds 30 mA within about 30 ms. It protects people from electric shock in wet areas like bathrooms and kitchens.
- Earth resistance limit
- Domestic earthing should measure below 5 ohms to the earth pit. Higher values mean poor earthing, so the pit needs watering, salt, or charcoal treatment.
- Megger insulation test
- A 500 V DC test between a winding and the metal body. A healthy domestic appliance reads above 1 megohm; a lower reading means moisture or insulation failure.
- Clamp meter use
- It measures AC current by surrounding one conductor only. Clamping both live and neutral together gives near zero because their magnetic fields cancel each other.
- Continuity test
- A multimeter buzzer or ohms check that confirms a closed path. A good fuse or switch reads near zero ohms, while an open circuit shows overload on the display.
- IEC wiring colours
- Brown is live, blue is neutral, and green-yellow is earth. The older Indian code used red for live, black for neutral, and green for earth.
- Switch in live conductor
- A switch must break the live wire, never the neutral. Switching the neutral leaves the appliance live even when it appears switched off, creating a shock hazard.
- Two-way switch strappers
- Two wires connect the L1 and L2 terminals of two SPDT switches. The live feeds the first common and the lamp connects to the second common terminal.
- Element resistance formula
- Resistance equals supply voltage squared divided by wattage (R = V squared divided by P). A 1000 W, 230 V element measures about 53 ohms when healthy.
- Geyser element leakage
- A geyser that trips the MCB often has a leaking element. A megger reading below 1 megohm from element to body confirms the element must be replaced.
- Induction cooktop principle
- Eddy currents induced in a ferromagnetic pan base produce heat. Glass, aluminium, and copper pans do not heat because they are not ferromagnetic and have low resistance.
- Universal motor brushes
- Mixer-grinder motors use carbon brushes on a commutator. Worn brushes below about 5 mm cause sparking, weak torque, and intermittent running and must be replaced.
- Fan capacitor fault
- A ceiling fan that hums but does not turn usually has a failed run capacitor. Replace it with the same microfarad and voltage rating to restore starting torque.
- Washing machine drain fault
- If the machine does not drain, check the drain filter, drain hose, and pump. A blocked filter or failed pump is the most common cause of this complaint.
- Submersible pump megger test
- Before installation, test winding insulation to body at 500 V DC. A reading below 1 megohm means water has entered the winding and the pump must be dried.
- Refrigeration cycle order
- Compressor, condenser, expansion device, then evaporator. Cooling occurs in the evaporator where low-pressure refrigerant absorbs heat from the cabinet or room.
- Superheat definition
- Evaporator outlet temperature minus the refrigerant saturation temperature at that pressure. Normal superheat is 5 to 8 K; higher values suggest undercharge.
- R-600a safety
- Isobutane refrigerant used in many domestic refrigerators is flammable. Ventilate the area, avoid sparks and open flames, and use spark-free vacuum equipment during service.
- AC capacity in tons
- One ton of cooling equals about 3.5 kilowatts of heat removal. Room size, insulation, and sun exposure determine the correct capacity for a split air conditioner.
- Triac regulator fault
- A shorted triac gives full power all the time in a fan regulator or dimmer. An open triac or faulty diac gives no output at all, so test both components.
- NTC thermistor
- A temperature sensor whose resistance falls as temperature rises. An open or wrong-value thermistor gives false temperature readings and error codes in inverter appliances.
- SMPS fuse check
- When the fuse in a switch-mode supply is blown, check the bridge rectifier and switching MOSFET for shorts before fitting a new fuse, or it will blow again.
- IPM module fault
- The intelligent power module drives the inverter compressor. An IPM error code usually means a shorted compressor winding or a failed module and heat sink compound.
- Diagnosis sequence
- Gather the complaint, check supply and plug, check fuse or MCB, then isolate the appliance and test components with a multimeter before opening any covers.
- Fuse replacement rule
- After replacing a blown fuse, find the cause. A fuse that blows again immediately indicates a short circuit downstream that must be located and repaired.
- Earth continuity test
- Measure resistance from the plug earth pin to the appliance metal body. It should be below 0.1 ohm; a higher value means a loose or broken earth connection.
- Job sheet record
- A written record of customer details, appliance model and serial number, fault found, parts replaced, tests done, and charges. It supports warranty claims and disputes.
- Service rate card
- A published list of diagnosis and labour charges by job type. It prevents billing disputes and helps the customer understand the cost before work begins.
- Repair warranty terms
- A service shop typically offers one to three months warranty on labour and parts. Manufacturer warranty covers defects, not misuse or accidental damage.
- Lock-out tag-out
- Switch off the isolator, lock it, attach a warning tag, and verify the circuit is dead with a tester before touching any conductor during repair work.
- Electrical fire extinguisher
- Class B electrical fires need carbon dioxide or dry powder extinguishers. Never use water, and switch off the mains supply before attempting to fight the fire.