InterNACHI HEA · Keep the key ideas within reach.

Quick reference

Building Science Fundamentals and Heat Transfer

  • Heat flows only from warmer to colder; the three modes are conduction (through solids), convection (fluid currents), and radiation (electromagnetic, needs no medium).

  • Conduction steady-state: Q = U × A × ΔT, where Q is Btu/h, U is Btu/(h·ft²·°F), A is ft², and ΔT is °F. R-value = 1/U.

  • Layered assemblies add resistances: R_total = R_si + R1 + R2 + … + R_se. Series heat flow is limited by the highest-resistance layer, so a thin low-R path controls performance.

  • U-factors for parallel paths must be area-weighted, not R-weighted: U_avg = (U1·A1 + U2·A2)/(A1 + A2). Framing fraction typically 15–25% of a wood-frame wall area.

  • Thermal bridging: a 2×6 stud at R-1.0 per inch interrupts cavity insulation; continuous exterior insulation reduces the penalty because it covers framing, not just cavities.

  • Sensible heat: Q = 1.08 × CFM × ΔT (Btu/h, sea level). Latent heat: Q_lat = 0.68 × CFM × Δgrains (Btu/h). Total = sensible + latent.

  • Infiltration heat loss is weather- and stack-driven; the simplified load term is Q ≈ 1.08 × CFM_infiltration × ΔT, with CFM from blower door results (CFM50 ÷ N-factor).

  • Water vapor moves by diffusion (slow, vapor pressure driven) and by air leakage (fast, carries far more moisture). Air sealing precedes vapor control in most mixed and cold climates.

  • Dew point: the temperature at which air reaches saturation. Surface condensation occurs when a surface temperature falls below the interior dew point; interstitial condensation occurs within the assembly.

Quick reference

Building Envelope Assessment (Insulation, Air Sealing, Windows and Doors)

  • Insulation levels are reported as installed R-value; verify grade (Grade I/II/III) and settled thickness, since compressed or gapped batts lose rated R-value.

  • Air sealing targets the pressure boundary: top plates, rim joists, penetrations, chases, attic hatches, and recessed fixtures. Leakage area scales with the pressure-boundary area, not floor area.

  • Window labels: U-factor (lower is better), SHGC (lower reduces cooling load), and air leakage (≤0.3 cfm/ft² for ENERGY STAR). NFRC ratings are whole-product values.

  • A window's effective R-value = 1/U-factor; a U-0.30 window is R-3.3, so replacing windows rarely beats attic air sealing and insulation on cost per unit of saved energy.

  • Door and window air leakage is often dwarfed by duct leakage and ceiling-plane bypasses; diagnose with a blower door before choosing upgrade scope.

  • Vapor retarder class is defined by permeance: Class I ≤0.1 perm, Class II 0.1–1.0, Class III 1.0–10. Cold-climate assemblies generally place low-perm material on the warm side.

  • Rim joists and band joists are common cold spots and condensation sites; air seal with rigid foam plus sealant, and insulate to match the wall assembly.

  • Knee walls, dormers, and cantilevers create uninsulated or open cavities; verify with IR imaging and confirm the thermal boundary is continuous and aligned with the pressure boundary.

  • Window and door replacement does not fix air leakage paths in the wall or ceiling plane; treat envelope as a system and verify with post-work blower door data.

Quick reference

HVAC Systems, Combustion Safety, and Ventilation

  • Heating equipment efficiency: AFUE = annual useful heat output ÷ annual fuel energy input. Combustion efficiency (stack test) is a single-point measure, not AFUE.

  • Cooling efficiency: SEER2 and EER2 are the current test-based ratings; HSPF2 covers heat pumps. Higher is better; match equipment size to Manual J load, not rules of thumb.

  • Refrigerant charge affects capacity and efficiency: a 10% undercharge can cut capacity measurably. Verify superheat/subcooling per manufacturer specs.

  • Combustion appliance categories: Category I (non-condensing, vent ≥140°F), Category IV (condensing, vent <140°F, PVC). Mismatched venting is a safety and durability failure.

  • Combustion safety tests: spillage (smoke pencil or flame at draft hood), draft pressure, CO in flue gas (air-free CO), and ambient CO. Air-free CO above 100 ppm warrants investigation; above 400 ppm is a red flag.

  • CAZ testing: measure worst-case depressurization with doors closed and exhaust fans running; compare to appliance limits (commonly −3 Pa for naturally drafting appliances, −5 Pa for Category I).

  • Ventilation standards: ASHRAE 62.2 whole-house ventilation rate ≈ 0.03 × floor area (ft²) + 7.5 × (bedrooms + 1) in CFM. Local exhaust for kitchens and baths runs separately.

  • Balanced ventilation (HRV/ERV) exchanges sensible heat; ERV also transfers moisture. Use ERV in humid cooling climates, HRV in cold dry climates.

  • Duct location matters: ducts in unconditioned attics can lose 20–30% of delivered energy. Sealing and burying ducts or moving them inside the envelope are high-value measures.

Quick reference

Blower Door and Duct Leakage Testing, Diagnostic Tools, Energy Modeling, Utility Bill Analysis, and Prioritizing Improvements

  • Blower door measures envelope leakage at a reference pressure (typically 50 Pa). Key outputs: CFM50, ACH50 = CFM50 × 60 ÷ conditioned volume (ft³), and CFM50 per ft² of envelope area.

  • Natural infiltration estimate: ACH_natural ≈ ACH50 ÷ N, where N ranges roughly 10–20 depending on climate and building height (LBL method uses local data).

  • Duct leakage: total leakage from a duct pressurization test (cfm25), expressed as % of system airflow. Duct leakage to outside requires a house-pressure-compensated test.

  • Leakage area estimate: ELA (in²) ≈ CFM50 ÷ 10 at 50 Pa for a sharp-edged orifice approximation; use only as a screening number.

  • Infrared thermography is valid only with a sufficient ΔT (generally ≥10–18°F) and steady conditions; solar gain, wind, and emissivity differences create false anomalies.

  • Utility bill analysis: normalize by HDD/CDD and floor area; whole-house baseload = total use minus weather-dependent use. Compare EUI (kBtu/ft²/yr) to ENERGY STAR Portfolio Manager benchmarks.

  • Energy modeling outputs are estimates, not guarantees; document assumptions (weather file, setpoints, occupancy, R-values) and calibrate to measured bills where possible.

  • Prioritization rule: rank measures by savings per dollar invested, then by health/safety and durability first, then comfort, then carbon. Air sealing and attic insulation usually precede HVAC replacement.

  • Measure stacking is non-additive: two measures each saving 20% combined save about 36%, not 40%, because savings interact. Model packages, not isolated measures.

Quick reference

Reporting, Client Communication, Program Standards, and Professional Ethics

  • Reports should separate measured data (blower door, IR, CO readings), observed conditions, and recommendations with estimated savings and cost basis; label estimates as estimates.

  • Health and safety findings (spillage, CO, mold, asbestos, knob-and-tube wiring) are reported immediately and take precedence over energy recommendations.

  • Scope statements must state what was and was not inspected (e.g., no destructive testing, no combustion appliance disassembly) to limit liability.

  • Program standards vary: BPI, RESNET/HERS, and utility weatherization programs each define test protocols, required forms, and allowable measures. Follow the governing program's standard.

  • Disclose conflicts of interest: if the auditor or firm also installs the recommended measures, disclose it and keep the audit independent of sales pressure.

  • Client communication: explain findings in plain language, tie recommendations to the client's stated goals (comfort, cost, health), and provide written next steps.

  • Data integrity: never fabricate test results or backdate reports. Record instrument calibration dates and test conditions (indoor/outdoor temperature, wind, baseline pressure).

  • Do not claim certification, affiliation, or ENERGY STAR program participation you do not hold; describe credentials accurately and keep continuing education current.

Quick reference

Building Science Fundamentals and Heat Transfer (supplemental)

  • Psychrometrics: relative humidity is the ratio of actual vapor pressure to saturation vapor pressure at the same temperature; warming air lowers RH without adding moisture.

  • Moisture balance: wetting (rain, plumbing, vapor diffusion, air transport) versus drying (ventilation, diffusion, drainage). Assemblies must dry in at least one direction.

  • Stack effect pressure ≈ 0.03 × h × (1/T_out − 1/T_in) in inches of water; taller buildings have stronger natural driving forces.

  • Wind pressure: P ≈ 0.00256 × V² × Cp (psf, V in mph). Wind and stack effects combine with mechanical fan pressure to set the house pressure field.

  • Latent heat of vaporization of water ≈ 970 Btu/lb; condensing 1 lb of water vapor releases roughly 1,000 Btu, which is why moisture problems often appear as heat and durability issues.

  • R-value of air films: interior surface ≈ 0.68, exterior winter ≈ 0.17 (h·ft²·°F/Btu). Ignoring air films overstates assembly R-value.

  • Degree-day method: annual heat loss ≈ (UA) × HDD × 24 ÷ ΔT_design basis; use HDD from the nearest weather station and adjust for base temperature.

  • Dense-pack cellulose in closed cavities reaches roughly 3.5–3.8 R per inch; spray foam 3.5–7 R per inch depending on type. Values vary by product; use manufacturer data.

Quick reference

HVAC Systems and Duct Leakage (supplemental)

  • Manual J sizing uses room-by-room loads; Manual S selects equipment; Manual D sizes ducts. Oversizing causes short cycling, poor dehumidification, and higher cost.

  • Airflow rule: roughly 400 CFM per ton of cooling (range 350–450 depending on climate and latent load). Verify with a flow hood or static pressure traverse.

  • Static pressure budget: supply plus return external static pressure typically should not exceed 0.5 in. w.c. for residential blowers; high ESP signals undersized ducts or dirty coils.

  • Heat pump balance point: the outdoor temperature where capacity equals load. Below it, supplemental heat runs; above it, the heat pump alone suffices.

  • Combustion air: a confined space requires two permanent openings or a known infiltration rate; verify with CAZ test rather than assuming leakage supplies combustion air.

  • Duct leakage to outside is the metric that matters for energy; leakage into conditioned space affects distribution and pressure but not directly the energy loss.

  • Ventilation rate control: ASHRAE 62.2 allows credit for infiltration; calculate effective ventilation rate from blower door data, then size the fan to the difference.

  • Refrigerant leak detection: EPA Section 608 rules require leak repair for appliances above threshold charge within specified timeframes; document refrigerant type and charge.

Quick reference

Diagnostic Tools and Energy Modeling (supplemental)

  • Blower door calibration: check the manometer zero, fan calibration, and ring configuration; record baseline (house-to-outside) pressure before and after the test.

  • Pressure pan testing: measure pressure differences across outlets while the blower door runs; higher readings indicate leakier paths. Use for targeted air sealing, not for total leakage.

  • Duct blaster: measures total duct leakage at 25 Pa; leakage to outside requires a second test with the house at a controlled pressure.

  • Combustion analyzer: measures O2, CO, CO2, stack temperature, and calculates excess air and air-free CO. Excess air outside 3–9% (natural gas) signals a problem.

  • Moisture meters: pin-type measures conductivity at the surface; pinless measures capacitance through material. Both are relative indicators; calibrate and interpret by material.

  • Energy model calibration: compare modeled annual use to weather-normalized bills; a difference within ±10–15% is generally acceptable for program purposes.

  • Modeling inputs that most affect results: envelope R-values and leakage, HVAC efficiency and distribution losses, thermostat schedules, and internal gains.

  • Instrument documentation: record model, serial, calibration date, and test conditions for every diagnostic; results without conditions are not defensible.

Quick reference

Utility Bill Analysis and Prioritizing Improvements (supplemental)

  • Weather normalization: use HDD/CDD from the same period as the bills; a 12-month bill history captures seasonal variation better than a single month.

  • Baseload separation: plot monthly use against HDD/CDD; the y-intercept approximates non-weather use (water heating, appliances, lighting).

  • EUI = annual site energy (kBtu) ÷ conditioned floor area (ft²). Compare to ENERGY STAR Portfolio Manager medians for the building type and climate zone.

  • Simple payback = installed cost ÷ annual savings. It ignores measure life and fuel escalation; pair it with lifecycle cost or savings-to-investment ratio (SIR).

  • SIR = present value of savings ÷ present value of costs. Programs often require SIR ≥ 1.0; higher SIR ranks measures higher.

  • Measure priority order: health/safety, then building durability (air sealing, moisture control), then envelope, then HVAC, then renewables. Cheap envelope measures usually beat equipment replacement.

  • Interactive effects: envelope improvements reduce HVAC loads, so HVAC replacement savings shrink. Model the package and re-verify with post-retrofit bills.

  • Verify savings with a post-retrofit period and normalized comparison; measurement and verification (M&V) closes the loop and supports program claims.

Quick reference

Reporting, Communication, and Program Standards (supplemental)

  • A defensible report includes: scope, methods and instruments, measured data with conditions, observations, health/safety findings, recommendations with basis, and limitations.

  • Photos and thermal images should include date, time, location, and conditions (indoor/outdoor temperature, wind) so they can be interpreted later.

  • Client communication: confirm goals before the audit, present findings in plain language, and provide a written summary with prioritized next steps and estimated costs.

  • Program forms: BPI, RESNET, and utility programs specify required test values and pass/fail thresholds; complete them accurately and keep copies.

  • Ethics: disclose conflicts of interest, do not upsell unnecessary measures, do not misrepresent certifications, and protect client data.

  • Liability: state limitations clearly (no destructive testing, no code compliance determination unless contracted) and avoid guaranteeing savings.

  • Continuing education and certification maintenance are program requirements; lapsed credentials must not be represented as current.

  • Follow-up: offer a post-retrofit verification visit and document measured improvement (blower door, bills) to support both client trust and program reporting.

Quick reference

Combustion Safety and Ventilation (supplemental)

  • Spillage test: with the appliance firing and the CAZ at worst-case depressurization, check for spillage at the draft hood for at least 1–2 minutes after steady-state operation.

  • Draft measurement: a naturally drafting appliance typically needs −2 to −5 Pa at the vent connector; positive or near-zero draft signals a blocked or undersized vent.

  • Air-free CO = measured CO × (20.9 ÷ (20.9 − O2 measured)). It corrects for dilution and is the number to compare against limits.

  • Ambient CO action level: 9 ppm (8-hour average) and 35 ppm (1-hour) are common guidance limits; evacuate and ventilate if exceeded.

  • Ventilation: ASHRAE 62.2 requires whole-house mechanical ventilation in most new and renovated homes; local exhaust for baths (≥50 cfm intermittent) and kitchens (≥100 cfm intermittent).

  • Makeup air: large exhaust fans (range hoods >400 cfm) can backdraft appliances; provide makeup air or interlock per code.

  • Combustion air: verify the appliance has adequate combustion air; a CAZ test with all exhaust fans running reveals whether the appliance can draft safely.

  • Documentation: record CAZ pressure, spillage results, CO readings, and instrument calibration; these are the defensible record of a safety determination.

Quick reference

Envelope Assessment (supplemental)

  • Attic insulation: verify depth and settled density; blown cellulose at 3.5 lb/ft³ and fiberglass at ~1.5–2.5 lb/ft³ achieve rated R-value. Check for wind washing and baffles at eaves.

  • Wall insulation: dense-pack cellulose fills cavities and reduces convection; verify with IR and by checking density at test holes.

  • Air barrier continuity: trace from attic to foundation; common breaks are at rim joists, chases, and penetrations. A blower door plus IR finds them.

  • Windows: check for failed seals (fogging), air leakage at operable sashes, and thermal bridging through frames. Low-e coatings and argon fill improve U-factor.

  • Doors: weatherstripping, sweeps, and thresholds; a blower door with a smoke pencil identifies leakage paths at frames and undercuts.

  • Knee walls and sloped ceilings: verify insulation contact and air sealing; these are frequent bypasses to unconditioned space.

  • Foundation: rim joists, sill plates, and crawlspace vents. Sealed and insulated crawlspaces change the pressure boundary and must be modeled accordingly.

  • Verify with post-work blower door and IR; document before/after CFM50 and ACH50 to demonstrate improvement.

Quick reference

Energy Modeling and Utility Analysis (supplemental)

  • Model inputs: geometry, envelope R-values, infiltration (from blower door), HVAC efficiency, distribution losses, thermostat schedule, and internal gains.

  • Calibration: adjust infiltration and HVAC efficiency within reasonable ranges to match bills; do not tune inputs outside physical plausibility.

  • Weather files: use TMY data for the nearest station; microclimate differences (elevation, urban heat island) can shift results.

  • Savings estimates: report ranges, not single numbers, and state assumptions. Program savings claims require documented methods.

  • Utility rate structures: tiered, time-of-use, and demand charges change the value of measures; savings in kWh may not equal savings in dollars.

  • Baseload vs. weather-sensitive use: separating them reveals whether the biggest opportunity is envelope/HVAC or water heating/appliances/lighting.

  • Measure life: insulation 20–30+ years, HVAC 15–20, windows 20–30; lifecycle cost accounts for replacement timing.

  • Post-retrofit verification: compare normalized bills and repeat blower door; document actual vs. modeled savings.

Quick reference

Professional Ethics and Client Communication (supplemental)

  • Independence: the auditor should not have a financial interest in the recommended measures, or must disclose it clearly.

  • Accuracy: report only what was measured or observed; label estimates and assumptions. Never fabricate data or backdate reports.

  • Confidentiality: protect client data and do not share without consent, except as required by program or law.

  • Competence: stay within scope; refer to specialists (electricians, HVAC technicians, mold remediators) when findings exceed your qualifications.

  • Transparency: provide written scope, fees, and limitations before the audit; explain what the client will receive.

  • Respect: communicate findings without alarmism, tie recommendations to client goals, and provide clear next steps.

  • Program compliance: follow the governing program's protocols and forms; do not claim certifications or affiliations you do not hold.

  • Follow-up: offer verification and answer questions; document the client's decisions and any declined recommendations.

Quick reference

Diagnostic Tools and Blower Door Testing (supplemental)

  • Blower door setup: seal the door frame, connect the manometer, zero it, and record baseline pressure before installing the fan.

  • Test protocol: depressurize to 50 Pa, record CFM50, and note conditions (wind, temperature, stack). Multiple-point tests improve accuracy.

  • ACH50 = CFM50 × 60 ÷ volume. A tight house is often defined as ≤3 ACH50 in cold climates; older homes commonly exceed 10.

  • Duct blaster: connect to the air handler, seal registers, and pressurize to 25 Pa; record total leakage and, with house compensation, leakage to outside.

  • IR camera: use with ΔT ≥10–18°F, avoid solar gain, and interpret emissivity differences. Confirm anomalies with a moisture meter or smoke pencil.

  • Smoke pencil: trace air leakage paths at the pressure boundary; useful for targeted air sealing and client education.

  • Combustion analyzer: measure O2, CO, CO2, stack temp; calculate excess air and air-free CO. Record calibration date.

  • Documentation: record instrument model, serial, calibration date, and test conditions for every measurement.

Quick reference

Prioritizing Improvements and Reporting (supplemental)

  • Rank by savings per dollar, then health/safety, durability, comfort, and carbon. Air sealing and attic insulation usually rank high.

  • Package modeling: account for interactive effects; savings are non-additive and shrink as measures stack.

  • Cost basis: use installed cost including labor, permits, and any required upgrades (e.g., ventilation when air sealing tightens the house).

  • Report structure: scope, methods, data, observations, health/safety, recommendations with basis, limitations, and next steps.

  • Client communication: confirm goals, explain findings in plain language, and provide a written summary with prioritized actions.

  • Program standards: follow the governing program's protocols, forms, and thresholds; document compliance.

  • Ethics: disclose conflicts, do not upsell, do not misrepresent credentials, and protect client data.

  • Verification: offer post-retrofit testing and bill comparison to document actual savings.

Quick reference

Building Science and Heat Transfer (supplemental)

  • Heat transfer modes: conduction (Q = U·A·ΔT), convection (fluid motion), radiation (Q = ε·σ·A·(T1⁴ − T2⁴)).

  • R-value = 1/U; layered assemblies add R; parallel paths area-weight U-factors.

  • Air leakage carries both heat and moisture; air sealing is often the highest-value measure.

  • Psychrometrics: RH depends on temperature; warming air lowers RH without adding moisture.

  • Dew point and surface temperature determine condensation risk; interstitial condensation depends on vapor pressure and permeance.

  • Stack and wind drive natural infiltration; mechanical fans change the pressure field and can backdraft appliances.

  • Moisture balance: assemblies must dry in at least one direction; vapor retarders belong on the warm side in cold climates.

  • Degree-day method estimates annual heat loss from UA and HDD.

Quick reference

HVAC and Ventilation (supplemental)

  • AFUE, SEER2, EER2, and HSPF2 are the efficiency metrics; match equipment to Manual J load.

  • Airflow: ~400 CFM per ton cooling; verify external static pressure ≤0.5 in. w.c. for residential blowers.

  • Refrigerant charge affects capacity; verify superheat/subcooling per manufacturer specs.

  • Combustion safety: spillage, draft, CO, and CAZ testing; air-free CO above 100 ppm warrants investigation.

  • Ventilation: ASHRAE 62.2 whole-house rate ≈ 0.03 × floor area + 7.5 × (bedrooms + 1) CFM.

  • HRV vs. ERV: ERV transfers moisture, HRV does not; choose by climate.

  • Duct location and leakage: ducts in unconditioned space lose 20–30% of delivered energy; seal and bury or move inside.

  • Makeup air for large exhaust fans prevents backdrafting.

Quick reference

Utility Bill Analysis and Energy Modeling (supplemental)

  • Weather normalization uses HDD/CDD from the same period as the bills; 12 months captures seasonal variation.

  • Baseload separation: plot use vs. HDD/CDD; the intercept approximates non-weather use.

  • EUI = annual site energy (kBtu) ÷ floor area (ft²); compare to Portfolio Manager benchmarks.

  • Simple payback = cost ÷ annual savings; pair with lifecycle cost or SIR.

  • SIR = present value of savings ÷ present value of costs; programs often require SIR ≥ 1.0.

  • Model calibration: compare modeled use to normalized bills; ±10–15% is generally acceptable.

  • Interactive effects: envelope improvements reduce HVAC loads, so equipment savings shrink.

  • Post-retrofit M&V closes the loop and supports program claims.

Quick reference

Reporting, Ethics, and Program Standards (supplemental)

  • Reports separate measured data, observations, and recommendations; label estimates.

  • Health and safety findings take precedence over energy recommendations.

  • State scope and limitations clearly (no destructive testing, no code determination unless contracted).

  • Follow the governing program's protocols and forms; do not claim certifications you do not hold.

  • Disclose conflicts of interest and keep the audit independent of sales pressure.

  • Communicate in plain language, tie recommendations to client goals, and provide written next steps.

  • Protect client data and do not share without consent.

  • Offer post-retrofit verification and document actual savings.