InterNACHI HEA: HVAC Systems, Combustion Safety, and Ventilation

InterNACHI HEA · Work through your exam, one topic at a time.

All guide sections

HVAC Systems, Combustion Safety, and Ventilation

HVAC Systems, Combustion Safety, and Ventilation

This domain tests equipment efficiency, airflow, combustion appliance testing, and whole-house ventilation. Expect questions on AFUE, SEER2, HSPF2, static pressure, worst-case depressurization, CO action levels, and ASHRAE 62.2.

Core rules

  • AFUE rates furnaces and boilers; SEER2 rates cooling; HSPF2 rates heat pumps. Higher is better, but installed performance depends on duct design, charge, and airflow.
  • Typical target airflow is about 350–450 CFM per ton of cooling. High static pressure indicates restrictive ducts or filters.
  • Combustion safety testing includes the combustion appliance zone (CAZ), worst-case depressurization, draft measurement, spillage observation, and CO measurement in ambient air and flue gas.
  • Many programs use action levels of 35 ppm ambient CO and 100 ppm air-free flue CO; know your program's thresholds and evacuation procedures.
  • ASHRAE 62.2 provides whole-house ventilation rates. For a 2,000 ft², 3-bedroom home, Q = 0.01 × 2,000 + 7.5 × (3 + 1) = 50 CFM.
  • Ventilation options include exhaust-only, supply-only, balanced, HRV, and ERV. HRVs/ERVs recover heat; ERVs also transfer moisture.

Worked example

A 2,000 ft² home with 3 bedrooms needs 50 CFM continuous per the 62.2 formula. A 50 CFM bath fan run continuously satisfies the rate but may cause depressurization; a balanced ERV avoids starling the CAZ and is preferable where combustion appliances are present.

Traps

  • Testing draft before worst-case depressurization.
  • Testing only one appliance when multiple share the CAZ.
  • Confusing flue CO with ambient CO.
  • Confusing ventilation CFM with infiltration CFM.
  • Ignoring duct leakage and return-path restrictions.