CLIA flashcards
CLIA · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- CLIA certificate types
- Certificate of Waiver, Provider-Performed Microscopy certificate, Certificate of Compliance, and Certificate of Accreditation; the certificate must match the complexity of testing performed.
- CLIA-exempt states
- States approved by CMS as having requirements equal to or more stringent than CLIA; Washington and New York are currently approved. Laboratories in these states follow state rules instead of CLIA.
- CLIA number
- The unique identifier assigned to a laboratory by CMS; required before patient testing begins and used on test reports and claims.
- Laboratory director accountability
- The director is responsible for overall operation and may delegate duties in writing but remains accountable for compliance with CLIA requirements.
- Change notification
- Laboratories must notify CMS within 30 days of changes in ownership, name, location, director, or test menu.
- High complexity director qualifications
- Requires a doctoral degree in a relevant field plus documented experience, or board certification, or qualifying experience under grandfather provisions.
- General supervisor duties
- Responsible for daily supervision of testing personnel and reporting of results; qualifications vary by complexity and specialty.
- Competency assessment frequency
- Semiannually during the first year and annually thereafter for each individual performing testing, including direct observation and review of results.
- Testing personnel training
- Documented training for each test system must be completed before an individual performs patient testing independently.
- Clinical consultant role
- A qualified physician or doctoral-level individual who consults on test ordering and interpretation and is available to assist with patient care decisions.
- PT sample handling
- PT samples must be tested like patient samples, not referred to another laboratory, and not shared with other laboratories before the due date.
- PT acceptable performance
- At least 80% of PT results for a test event must fall within acceptable performance limits; failure of two consecutive or two of three consecutive events is unsuccessful.
- PT director review
- The laboratory director must review and sign PT results before submission, and PT records must be retained for two years.
- No approved PT program
- For tests without a CMS-approved PT program, the laboratory must use an alternative assessment such as split-sample testing or comparison with another laboratory.
- PT referral prohibition
- Laboratories may not refer PT samples to another laboratory for testing, and violations can lead to sanctions including certificate revocation.
- QC two levels
- For many quantitative tests, at least two control levels must be tested each day of testing, or as specified by the manufacturer.
- Performance specifications
- Documented accuracy, precision, analytical sensitivity, analytical specificity, reportable range, and reference intervals must be established for each test system.
- Quality assessment program
- An ongoing program that monitors preanalytical, analytical, and postanalytical processes, reviews complaints and incidents, and documents corrective actions.
- QC corrective action
- When QC results are outside limits, the laboratory must repeat controls, evaluate affected patient results, and document the corrective action taken.
- QC record retention
- QC records must be reviewed and signed by the director or designee and retained for at least two years.
- Specimen labeling
- Specimens must be labeled with at least two unique patient identifiers at the time of collection, and labeling deficiencies must follow a documented rejection policy.
- Critical value reporting
- Critical results must be reported immediately to the responsible caregiver, and the notification must be documented with time and recipient.
- Reference intervals
- The laboratory must establish and document reference intervals for each test and make them available to ordering providers.
- Verbal test orders
- The laboratory must have a written policy for accepting and authenticating verbal orders, and the order must be documented in the medical record.
- Bloodborne pathogens standard
- OSHA requires an exposure control plan, hepatitis B vaccination offered to at-risk employees, universal precautions, and post-exposure follow-up.
- Hand hygiene
- Hand hygiene must be performed before and after patient contact and after glove removal; alcohol-based rub is acceptable when hands are not visibly soiled.
- Sharps disposal
- Sharps must be placed in puncture-resistant, closable containers near the point of use; recapping by hand is prohibited unless a mechanical device or single-handed technique is used.
- Chemical hazard communication
- Requires a chemical inventory, safety data sheets, labeling of secondary containers, and training for employees who handle hazardous chemicals.
- Biennial inspection
- Laboratories with a Certificate of Compliance are inspected every two years by CMS or a state agency; accredited laboratories are inspected by their accrediting organization.
- Condition-level deficiency
- A serious inspection finding that may result in a directed plan of correction, civil money penalties, or suspension of the certificate if not corrected.
- Approved accrediting organizations
- CMS-approved accrediting organizations, including CAP, The Joint Commission, and COLA, must have standards equivalent to or more stringent than CLIA.
- Waived testing requirements
- A Certificate of Waiver laboratory must follow manufacturer instructions, maintain training and QC records for two years, and permit inspections.