Engineer Noise and Vibration study materials
Engineer Noise and Vibration study resources

Engineer Noise and Vibration cheat sheet

Engineer Noise and Vibration · Keep the key ideas within reach.

Quick reference

Fundamentals of Acoustics and Vibration

  • Sound pressure level: Lp = 20 log10(p/p0), p0 = 20 µPa; sound power level: Lw = 10 log10(W/W0), W0 = 1 pW; intensity level: LI = 10 log10(I/I0), I0 = 1 pW/m².

  • Decibel addition: L_total = 10 log10(Σ 10^(Li/10)); adding two equal levels raises the sum by 3 dB, and a source 10 dB lower adds 0.4 dB.

  • For a point source in a free field, SPL falls 6 dB per doubling of distance; for a line source (road traffic at moderate distance) the fall is 3 dB per doubling.

  • A-weighting approximates the 40-phon equal-loudness contour; B- and C-weighting correspond to 70 and 100 phon. C-weighting is used for peak and high-level assessments.

  • Frequency bands: octave band edges follow fc = 1000·2^n with f_upper/f_lower = 2; one-third-octave bands use ratio 2^(1/3) ≈ 1.26, and the 1 kHz band spans 891–1122 Hz.

  • Room acoustics: reverberation time Sabine formula RT60 = 0.161 V/A (metric, V in m³, A in m² sabins); absorption coefficient α = absorbed/incident energy.

  • Simple harmonic motion: x = X sin(ωt), velocity amplitude v = ωX, acceleration amplitude a = ω²X; at 1 kHz, a = 1 m/s² corresponds to v ≈ 0.159 mm/s and x ≈ 25 nm.

  • Vibration descriptors: RMS, peak, peak-to-peak, and crest factor = peak/RMS; for a sinusoid RMS = peak/√2 and crest factor = 1.414.

  • Frequency weighting for hand-arm vibration: Wh weights mid frequencies most heavily; for whole-body vibration Wk is the primary weighting, with Wd, Wf, Wc used for specific axes and conditions.

Quick reference

Measurement, Instrumentation and Signal Analysis

  • Sound level meters are graded by IEC 61672 as Class 1 or Class 2; Class 1 has tighter tolerances (±0.7 dB at reference conditions versus ±1.0 dB for Class 2).

  • Before and after each measurement set, calibrate with a pistonphone or sound calibrator; a drift greater than 0.5 dB invalidates the measurement and requires investigation.

  • Fast (F) time weighting is 125 ms, Slow (S) is 1000 ms, and Impulse (I) is 35 ms rise with a slower decay; LAeq is an energy average and is independent of time weighting.

  • LAeq,T = 10 log10[(1/T)∫(pA²/p0²)dt]; for discrete samples, LAeq = 10 log10[(1/N)Σ10^(Li/10)].

  • LAE (SEL) = LAeq + 10 log10(T/T0) with T0 = 1 s; Lden = 10 log10[(1/24)(12·10^(Lday/10) + 4·10^((Levening+5)/10) + 8·10^((Lnight+10)/10))].

  • A single-number rating from octave-band data: for airborne sound insulation, Rw is derived from the reference curve; for impact sound, Ln,w uses a shifted reference curve.

  • FFT analyzer: frequency resolution Δf = fs/N and record length T = 1/Δf; a Hanning window reduces spectral leakage but broadens peaks by about 1.5 bins.

  • Nyquist criterion: sampling frequency must exceed twice the highest frequency of interest; anti-alias filtering is required before sampling.

  • Microphone directivity and wind: use a windscreen outdoors, and note that wind-induced noise on a 200 mm windscreen can bias low-level measurements; a 90 mm windscreen is standard for environmental work.

Quick reference

Occupational Noise Exposure and Hearing Conservation

  • OSHA PEL: 90 dBA as an 8-hour TWA with a 5 dB exchange rate; the action level is 85 dBA TWA, triggering audiometric testing and training.

  • OSHA hearing conservation program triggers at 85 dBA TWA; engineering and administrative controls are required before relying on hearing protectors at or above 90 dBA.

  • NIOSH REL: 85 dBA for 8 hours with a 3 dB exchange rate; permissible time T = 8/2^((L−85)/3) hours.

  • Dose conversion: D = 100·(C1/T1 + C2/T2 + …); a dose of 100% at the OSHA criterion equals 90 dBA TWA.

  • Standard threshold shift (OSHA): average change of 10 dB or more at 2000, 3000, and 4000 Hz in either ear; recordable if the shift averages 10 dB and the hearing level is 25 dB or more.

  • Hearing protector attenuation: NRR (EPA) is applied as estimated exposure = dBA − (NRR − 7); derating factors of 25% (OSHA), 50% (NIOSH), or 75% may be applied.

  • Impulse noise: OSHA sets a 140 dB peak limit; NIOSH recommends 140 dBC peak for impulse and 85 dBA for continuous exposure.

  • Audiometric testing: baseline within 6 months of first exposure, annual thereafter; test in a booth meeting ANSI S3.1 background noise limits.

Quick reference

Environmental Noise Assessment and Modeling

  • Propagation outdoors: geometric spreading, atmospheric absorption (increases with frequency and humidity), ground effect, and barrier insertion loss; a barrier must break line of sight to be effective.

  • Barrier insertion loss is limited to about 20 dB in practice; the Maekawa method uses Fresnel number N = 2δ/λ, with IL ≈ 10 log10(3 + 20N).

  • Atmospheric absorption at 4 kHz is roughly 10–30 dB/km depending on temperature and humidity; at 125 Hz it is under 1 dB/km.

  • Lden uses day 07:00–19:00, evening 19:00–23:00 (+5 dB), and night 23:00–07:00 (+10 dB); Ldn uses day/night with a +10 dB night penalty.

  • Lnight is the A-weighted equivalent level over the night period and is the EU indicator for sleep disturbance assessment under the Environmental Noise Directive.

  • Road traffic: pass-by level depends on speed, pavement type, and gradient; a 3 dB change is generally the threshold of noticeable change in steady traffic noise.

  • Aircraft noise: SEL and LAmax are used for single events; cumulative metrics include Lden and the number-above-threshold approach (NAT).

  • Meteorological effects: temperature inversions and downwind propagation can increase levels by 10 dB or more at distances over 500 m compared with neutral conditions.

Quick reference

Noise and Vibration Control Engineering

  • Control hierarchy: reduce at source, then path, then receiver; source control is generally the most cost-effective and durable.

  • Mass law for a single-leaf partition: TL ≈ 20 log10(m·f) − 47 dB (m in kg/m², f in Hz); doubling mass or frequency adds about 6 dB.

  • Coincidence dip occurs when the trace wavelength in the panel matches the airborne wavelength; it lowers TL around the critical frequency fc = c²/(1.8·cL·h).

  • A double-leaf partition outperforms a single leaf of equal mass if the cavity is at least 50–100 mm and filled with absorptive material; the mass-air-mass resonance must be placed below the frequency range of concern.

  • Silencer types: dissipative (absorptive) silencers attenuate mid-to-high frequencies; reactive silencers attenuate low frequencies via expansion chambers and resonators.

  • Vibration isolation: transmissibility T = 1/|1 − (f/fn)²| for an undamped system; isolation begins above f/fn = √2 and improves 12 dB per octave beyond it.

  • Static deflection δ (mm) relates to natural frequency: fn ≈ 15.76/√δ Hz; a 25 mm deflection gives about 3.2 Hz.

  • Structure-borne transmission is controlled with resilient mounts, inertia blocks, and flexible couplings; rigid connections short-circuit isolation and must be avoided.

Quick reference

Human Response, Criteria and Standards

  • Hearing damage risk increases with both level and duration; the equal-energy hypothesis underlies the 3 dB exchange rate used by NIOSH and ISO 1999.

  • Presbycusis: hearing threshold rises with age, roughly 1 dB per year above 1 kHz after age 40 for men, less for women; ISO 7029 provides age-related distributions.

  • Noise-induced hearing loss typically shows a notch at 3000–6000 Hz, most often at 4000 Hz, with recovery at 8000 Hz.

  • Annoyance: ISO/TS 15666 specifies the 11-point numerical scale and the 5-point verbal scale for social surveys; %HA is often modeled from Lden.

  • Sleep disturbance: Lnight is the primary EU indicator; intermittent events and LAmax inside bedrooms are relevant to awakening.

  • Vibration: ISO 2631-1 uses frequency-weighted acceleration and the daily vibration dose value VDV = [∫a_w⁴(t)dt]^(1/4); the eVDV estimate is 1.4·a_w·T^(1/4).

  • Hand-arm vibration: ISO 5349-1 uses A(8) = a_hv·√(T/T0) with T0 = 8 h; the EU action value is 2.5 m/s² A(8) and the limit value is 5 m/s² A(8).

  • Whole-body vibration: EU action value is 0.5 m/s² A(8) and the exposure limit value is 1.15 m/s² A(8) or a VDV of 21 m/s^1.75.

Quick reference

Professional Practice, Ethics and Reporting

  • Report the instrument class, calibration record, time weighting, frequency weighting, measurement duration, and meteorological conditions so results can be reproduced.

  • State the standard or guideline used (for example ISO 1996-2 or ANSI S1.4) and the metric (LAeq, Lden, LAmax); mixing metrics without labeling them is misleading.

  • Measurement uncertainty should be reported; typical expanded uncertainty for environmental LAeq is about 2–3 dB, and compliance decisions should account for it.

  • Conflicts of interest must be disclosed; an assessor who also designs the mitigation should state that relationship in the report.

  • Do not present modeled results as measured data; identify model name, version, input assumptions, and validation against measurements.

  • Retain raw data and calibration certificates for the period required by the client or regulator; chain of custody matters if results may be contested.

  • When results exceed a criterion, state the exceedance in dB and the affected period; avoid qualitative language such as "slightly above" without numbers.

  • Peer review and independent verification are appropriate for large projects; document reviewer identity and scope.

Quick reference

Fundamentals - Units, Levels and Basic Relationships

  • Reference values: p0 = 20 µPa, I0 = 1 pW/m², W0 = 1 pW; these are the anchors for all dB conversions.

  • Sound pressure and intensity are related by I = p²/(ρc); at 20 °C and 101.3 kPa, ρc ≈ 415 N·s/m³.

  • A 10 dB increase is perceived as roughly a doubling of loudness; a 3 dB change is barely perceptible in steady broadband noise.

  • Combining incoherent sources: L = 10 log10(10^(L1/10) + 10^(L2/10)); coherent sources require amplitude addition before conversion.

  • Wavelength λ = c/f; at 20 °C, c ≈ 343 m/s, so 100 Hz has λ ≈ 3.43 m and 1 kHz has λ ≈ 0.343 m.

  • Speed of sound in air rises with temperature: c ≈ 331.3 + 0.606·T (°C) m/s.

  • Standing waves form when a dimension is a multiple of λ/2; room modes cause uneven low-frequency response below the Schroeder frequency.

  • Loudness level in phons equals the SPL of a 1 kHz tone judged equally loud; sones are proportional to loudness, with 1 sone = 40 phon.

Quick reference

Measurement - Field Practice and Instrumentation Details

  • Microphone height for environmental measurements is typically 1.2–1.5 m above ground for facade or free-field assessment; report the actual height used.

  • Free-field versus diffuse-field microphone correction: apply the appropriate correction when the sound field differs from the microphone's design field.

  • A calibrated pistonphone produces a known level (commonly 94 dB at 1 kHz); record the pre- and post-measurement calibration values.

  • Background noise correction: if the background is 3 dB below the total, the source level is uncertain; a 10 dB difference gives a 0.4 dB correction.

  • Leq over a period can be computed from short-term samples only if the sampling is representative; report sampling interval and weighting.

  • Wind noise: use a windscreen and orient the microphone; discard data with wind speeds above the manufacturer's limit (often 5 m/s for a 90 mm screen).

  • Tone assessment: use a method such as ISO/PAS 20065 or the ANSI S1.13 tone-to-noise ratio; a prominent tone may warrant a penalty of up to 5–6 dB.

  • Vibration measurement: mount accelerometers rigidly and consider the mounted resonance; a mounting resonance below 3× the measurement range causes errors.

Quick reference

Occupational - Exposure Calculation and Program Management

  • TWA from task durations: TWA = 16.61·log10(D/100) + 90 for the OSHA 5 dB exchange rate, where D is the dose in percent.

  • For a 3 dB exchange rate, TWA = 85 + 10·log10(D/100) with D referenced to 85 dBA for 8 hours.

  • Partial-period exposure: compute each task's contribution C/T and sum; if the sum exceeds 1.0, the exposure exceeds the criterion.

  • Hearing protector selection: choose protectors that bring exposure below 85 dBA; over-protection can impair communication and warning signal detection.

  • Audiometric follow-up: a confirmed STS requires retest within 30 days and notification; the employer must fit or refit hearing protectors and provide training.

  • Recordkeeping: OSHA requires noise exposure records for 2 years and audiometric records for the duration of employment plus 30 years.

  • Engineering controls: enclosures, silencers, and damping are preferred; administrative controls such as rotation are temporary and must not be used to avoid feasible engineering controls.

  • Training must cover effects of noise, purpose of protectors, fitting, and audiometric testing; repeat annually.

Quick reference

Environmental - Metrics, Modeling and Compliance

  • ISO 1996-2 covers determination of environmental noise levels; ISO 1996-1 covers descriptors and basic quantities including Lden and Lnight.

  • LAmax is the maximum A-weighted level with a specified time weighting (often Fast); report the weighting because Fast and Impulse give different maxima.

  • Percentile levels: L10, L50, and L90 describe the distribution; L90 is often used as a background indicator and L10 as a peak-traffic indicator.

  • Modeling inputs: source emission levels, receiver coordinates, ground impedance, barrier geometry, and meteorology; document each input source.

  • Barrier design: place the barrier close to the source or receiver, ensure it breaks line of sight, and avoid gaps; a small gap can severely reduce insertion loss.

  • Construction noise: many jurisdictions set limits by time period and by sensitive receptor type; report the applicable limit alongside measured levels.

  • Wind turbine noise: amplitude modulation and low-frequency content are assessed separately from LAeq; tonal and impulsive penalties may apply.

  • Compliance reporting should state the averaging period, the number of valid samples, and whether unfavorable meteorological conditions were included.

Quick reference

Control Engineering - Practical Measures and Verification

  • Source control options: quieter equipment, reduced speeds, damping treatments, and improved maintenance; a 3 dB reduction requires halving the sound power.

  • Enclosure design: use absorptive lining, minimize openings, and seal penetrations; an enclosure's insertion loss is limited by leaks and by structure-borne paths.

  • HVAC noise: use duct silencers, flexible connectors, and lined ducts; airflow-generated noise increases roughly with the sixth power of velocity.

  • Vibration isolation selection: choose a mount whose natural frequency is at most one-third of the lowest forcing frequency; verify with the static deflection.

  • Damping reduces resonant response; constrained-layer damping is effective for thin panels and plates.

  • Commissioning: verify mitigation performance with before/after measurements at the same positions and conditions; report the achieved insertion loss.

  • Maintenance matters: worn bearings and loose panels raise noise; periodic inspection preserves the designed performance.

  • Cost-effectiveness: prioritize measures by dB reduction per unit cost and by the number of people affected.

Quick reference

Human Response - Criteria Application and Interpretation

  • Annoyance increases with Lden but also depends on the character of the noise: tonal, impulsive, or low-frequency noise produces more annoyance at the same level.

  • Low-frequency noise: below about 100 Hz, A-weighting underestimates effects; use C-weighted or linear levels and specific criteria such as the Swedish or Danish low-frequency limits.

  • Speech interference: the speech interference level (SIL) is the average of octave-band levels at 500, 1000, 2000, and 4000 Hz; an SIL around 45 dB allows relaxed conversation at 1 m.

  • Vibration comfort: ISO 2631-1 provides comfort reactions and uses frequency weightings Wk, Wd, and Wf depending on axis and posture.

  • Combined exposure to noise and vibration can increase discomfort; assess both when the workplace involves both.

  • Children and the elderly are generally more sensitive to noise; criteria for schools and hospitals are typically stricter than for residential areas.

  • Tonal penalty: a clearly audible tone may add 5 dB to the assessed level in some national schemes; document the method used.

  • Reporting human response: distinguish measured exposure from predicted response and avoid asserting health outcomes without evidence.