Engineer Noise and Vibration flashcards
Engineer Noise and Vibration · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Sound pressure level formula
- Lp = 20 log10(p/p0), where p0 = 20 µPa. A pressure of 0.2 Pa corresponds to 80 dB and 2 Pa to 100 dB.
- Decibel addition of two sources
- For incoherent sources, L_total = 10 log10(10^(L1/10) + 10^(L2/10)). Two equal 70 dB sources combine to 73 dB, an increase of 3 dB.
- A-weighting purpose
- A-weighting approximates the ear's sensitivity at moderate levels, based on the 40-phon equal-loudness contour. It is the standard weighting for occupational and environmental noise assessment.
- Sabine reverberation formula
- RT60 = 0.161 V/A in metric units, where V is room volume in m³ and A is total absorption in m² sabins. Doubling absorption halves reverberation time.
- Simple harmonic acceleration
- For displacement amplitude X and angular frequency ω, acceleration amplitude is ω²X. Acceleration rises 12 dB per doubling of frequency for constant displacement.
- Octave band center frequencies
- Standard octave bands run 31.5, 63, 125, 250, 500, 1000, 2000, 4000, 8000, and 16000 Hz. Each band's upper edge is twice its lower edge.
- Class 1 versus Class 2 meters
- IEC 61672 defines Class 1 and Class 2 sound level meters. Class 1 has tighter tolerances, about ±0.7 dB at reference conditions, versus ±1.0 dB for Class 2.
- Time weightings Fast Slow Impulse
- Fast is 125 ms, Slow is 1000 ms, and Impulse has a 35 ms rise time with slower decay. LAeq is an energy average and does not depend on time weighting.
- Sound exposure level LAE
- LAE = LAeq + 10 log10(T/T0) with T0 = 1 s. It condenses a single event's energy into a one-second equivalent level for comparison.
- FFT frequency resolution
- Frequency resolution equals sampling frequency divided by number of samples, and also equals the reciprocal of record length. A 1 s record gives 1 Hz resolution.
- Calibration drift acceptance
- A post-measurement calibration drift greater than 0.5 dB generally invalidates the measurement set. Record pre- and post-calibration values with the instrument serial number.
- OSHA permissible exposure limit
- OSHA sets a PEL of 90 dBA as an 8-hour time-weighted average with a 5 dB exchange rate. The action level is 85 dBA TWA.
- NIOSH recommended exposure limit
- NIOSH recommends 85 dBA for 8 hours with a 3 dB exchange rate. Permissible time is T = 8/2^((L−85)/3) hours.
- Noise dose calculation
- Dose D = 100·(C1/T1 + C2/T2 + …), where C is actual exposure time and T is allowable time for that level. A dose of 100% equals the criterion level.
- Standard threshold shift definition
- OSHA defines an STS as an average change of 10 dB or more at 2000, 3000, and 4000 Hz in either ear, relative to the baseline audiogram.
- NRR derating method
- Estimated exposure = dBA − (NRR − 7). Derating factors of 25% (OSHA), 50% (NIOSH), or 75% may be applied to reflect real-world fit.
- Barrier insertion loss limit
- Practical barrier insertion loss is limited to about 20 dB. The barrier must break line of sight; small gaps and flanking paths reduce performance sharply.
- Lden weighting periods
- Lden uses day 07:00–19:00, evening 19:00–23:00 with a +5 dB penalty, and night 23:00–07:00 with a +10 dB penalty, averaged over 24 hours.
- Atmospheric absorption with frequency
- Atmospheric absorption rises with frequency: under 1 dB/km at 125 Hz but roughly 10–30 dB/km at 4 kHz, depending on temperature and humidity.
- Mass law transmission loss
- For a single-leaf partition, TL ≈ 20 log10(m·f) − 47 dB with m in kg/m² and f in Hz. Doubling mass or frequency adds about 6 dB.
- Vibration isolation transmissibility
- Transmissibility T = 1/|1 − (f/fn)²| for an undamped system. Isolation begins above f/fn = √2 and improves about 12 dB per octave beyond it.
- Static deflection and natural frequency
- Natural frequency fn ≈ 15.76/√δ Hz, where δ is static deflection in mm. A 25 mm deflection gives about 3.2 Hz.
- Coincidence dip in panels
- The coincidence dip lowers transmission loss when the trace wavelength in the panel matches the airborne wavelength. It occurs near the critical frequency of the panel.
- Noise-induced hearing loss notch
- Noise-induced hearing loss typically shows a notch at 3000–6000 Hz, most often at 4000 Hz, with partial recovery at 8000 Hz.
- Hand-arm vibration A(8)
- A(8) = a_hv·√(T/T0) with T0 = 8 h. The EU action value is 2.5 m/s² A(8) and the exposure limit value is 5 m/s² A(8).
- Whole-body vibration action values
- The EU action value for whole-body vibration is 0.5 m/s² A(8) and the exposure limit value is 1.15 m/s² A(8), or a VDV of 21 m/s^1.75.
- Vibration dose value formula
- VDV = [∫a_w⁴(t)dt]^(1/4), using frequency-weighted acceleration. The estimated eVDV equals 1.4·a_w·T^(1/4) for constant exposure.
- Report measurement uncertainty
- Environmental LAeq measurements typically carry an expanded uncertainty of about 2–3 dB. Compliance decisions should account for uncertainty rather than relying on a single point value.
- Report instrument and settings
- A defensible report states instrument class, calibration records, time and frequency weightings, measurement duration, positions, and meteorological conditions, so results can be reproduced independently.
- Modeled versus measured data
- Modeled results must be labeled as predictions, with model name, version, inputs, and any validation against measurements. Presenting predictions as measurements is misleading.
- Speed of sound in air
- Speed of sound in air is approximately 331.3 + 0.606·T m/s with T in °C, giving about 343 m/s at 20 °C. Wavelength equals c/f.
- Background noise correction
- If background is 10 dB below the total, subtract 0.4 dB; at 3 dB difference the correction is about 3 dB but uncertainty is large. Below 3 dB, results are unreliable.