Mistake 1

Adding sound pressure levels of several sources by summing their dB values arithmetically (e.g., 80 dB + 80 dB = 160 dB) instead of combining on a logarithmic/energetic basis.

Candidates carry over everyday linear arithmetic habits and forget that dB is a logarithmic ratio of mean-square pressure or intensity; the decibel is not a quantity that adds directly.

What to do instead

Convert each level back to a linear quantity (10^(L/10) for power-like quantities, or 10^(L/20) for pressure amplitude), sum, then take 10·log10 of the total. Memorise the quick rules: equal sources give +3 dB, and a source 10 dB below another adds only about 0.4 dB.

Mistake 2

Treating dB(A) as a simple correction added to a band level without first applying the A-weighting to each octave or third-octave band and then recombining energetically.

Candidates see A-weighting tables and apply the correction to an overall unweighted level, or add corrections linearly across bands, misunderstanding that A-weighting is per-frequency and the corrected bands must be summed logarithmically.

What to do instead

Apply the A-weighting correction to each individual band level, convert to linear energy, sum, and convert back. Practise with a worked third-octave example, and always state which weighting and which summation method was used.

Mistake 3

Reporting an overall sound level without specifying the weighting network, the time constant (Fast/Slow/Impulse), and the averaging period.

Candidates focus on getting the number right and treat the descriptor as an afterthought, not realising that the same signal can read several dB differently under Fast versus Impulse or A versus C weighting.

What to do instead

Adopt a reporting template that always pairs the numeric result with the full descriptor, e.g., 'LAeq,8h', 'LAFmax', 'LCpeak'. Before writing an answer, check that weighting, time constant, and averaging time are all stated.

Mistake 4

Confusing LAeq, LAFmax, and LCpeak and using the wrong one to judge a criterion, such as comparing an impulsive peak against an 8-hour average limit.

These descriptors look similar and candidates memorise the symbols without internalising what each represents: energy average, maximum Fast-weighted level, and unweighted peak pressure.

What to do instead

Build a mental table: LAeq = energy-equivalent average over a stated period; LAFmax = highest Fast-weighted A level; LCpeak = highest instantaneous C-weighted peak. Match each to the relevant exposure or hearing-conservation criterion before calculating.

Mistake 5

Computing an 8-hour time-weighted average by taking a simple arithmetic mean of levels across a shift rather than an energy-based dose with the exchange rate and threshold applied.

Candidates treat exposure as an average of dB readings and ignore that dose depends on duration, exchange rate (typically 3 dB), and criterion level, so short loud periods are under-weighted.

What to do instead

Use the fractional-dose method: D = 100·Σ(Ci/Ti), where Ci is time at a given level and Ti is the allowed time at that level from the criterion table. Sum fractions, then convert dose to TWA. Verify with a two-task worked example.

Mistake 6

Assuming a single measurement position or a single short sample represents the whole area, ignoring spatial variation, background contribution, and source directivity.

Candidates want a quick answer and underestimate how much level varies with distance, reflections, and background noise, so they skip sampling design and background correction.

What to do instead

Plan measurement positions and durations explicitly, take background levels, and apply background correction (e.g., subtract energetically, with a stated uncertainty when the difference is small). State the sampling rationale in the answer.

Mistake 7

Applying the inverse-square (6 dB per doubling of distance) rule to a source that is not a point source in free field, such as a line source, an extended source, or a source near reflecting surfaces.

The 6 dB rule is the most memorised formula and candidates apply it without checking geometry, directivity, ground effects, or whether the receiver is in the near field.

What to do instead

First classify the source and environment: point vs line vs area, free field vs reflecting, near field vs far field. Then select the correct propagation law (6 dB/doubling for a point source, 3 dB/doubling for an incoherent line source) and state assumptions.

Mistake 8

Selecting a noise-control measure without addressing the dominant transmission path, for example adding absorptive treatment when the problem is structure-borne or flanking transmission.

Candidates reach for familiar treatments (barriers, absorbers, enclosures) before diagnosing whether the path is airborne direct, airborne flanking, or structure-borne, so the intervention misses the controlling path.

What to do instead

Follow a path-analysis sequence: identify source, paths, and receiver; measure or reason about which path dominates; then choose control at source, path, or receiver in that priority order. Justify the choice against the identified dominant path.

Mistake 9

Ignoring human-response modifiers such as tonal content, impulsiveness, time of day, and duration when assessing annoyance or comparing to a criterion.

Candidates compare a single LAeq number to a limit and overlook that tonal or impulsive noise is judged more annoying at the same level, and that evening/night limits are often stricter.

What to do instead

Screen for tonality (narrowband peaks), impulsiveness, and timing, apply the relevant penalty or adjusted limit, and report the adjusted value alongside the raw LAeq. Cite the specific criterion being applied.

Mistake 10

Presenting results or recommendations without stating measurement uncertainty, instrument calibration status, standards followed, or limitations of the method.

Candidates treat the report as a place to show the final number and forget that professional practice requires traceability, calibration records, and honest statements of uncertainty and assumptions.

What to do instead

Include a methods-and-limitations section: instrument make/model, calibration before and after, standards referenced, uncertainty budget, and assumptions. Phrase conclusions as conditional on those assumptions, and flag where data are insufficient.