KY HVAC · Put your knowledge to work in context.

The Kentucky HVAC Contractor Licensing Examination is a trade licensure exam for people who intend to contract for heating, ventilation and air conditioning work in the Commonwealth. It is aimed at experienced technicians moving into business ownership as well as established contractors adding a credential, and it tests the full scope of the trade rather than a single product line: refrigeration principles and system components, heating equipment and combustion safety, air distribution, ventilation and indoor air quality, electrical systems, motors and controls, load calculation, sizing and system design, and the codes, permits and business practices that govern contracting. The statewide regulatory backdrop is the Kentucky Department of Housing, Buildings and Construction, which states that it "enforces statewide standards for building construction" and licenses and certifies trades including plumbers, electricians, boiler contractors, sprinkler and fire alarm contractors and building inspectors. Candidates should confirm current application, examination and renewal requirements directly with the department, because the agency's published news items - including a July 15, 2026 item titled "HVAC Equipment" and 2026 NEC updates - do not state any resulting change to HVAC examination content, item counts or pass standards. The KY HVAC case studies are 5 cases and about 2,147 words.

1

Walk-In Cooler Repeat Refrigerant Loss

You are called to a convenience store walk-in cooler using R-404A. The box is 8 ft by 10 ft by 8 ft and should hold 35°F; product temperature is 44°F.

509 words, about 3 min
2

Natural-Draft Furnace Spillage and CO

A 100,000 BTU/h natural-gas, 80% AFUE furnace is in a basement. It vents through a 6 in.

378 words, about 2 min
3

High Static Pressure and Closed-Door Bedrooms

A 2,000 sq ft single-story house has a 3-ton air handler rated at 1,200 CFM. Measured external static pressure is 0.90 in.

449 words, about 2 min
4

Condenser Fan Motor Tripping Breaker

A 3-ton split system condenser fan motor trips the 25 A breaker after 8 to 10 minutes. Nameplate: 208/230 V, 1/4 hp, 1.8 A.

393 words, about 2 min
5

Furnace Replacement Sizing and Permit Review

A 1,800 sq ft ranch in Kentucky has an existing 80,000 BTU/h input, 80% AFUE furnace. A contractor proposes a 90,000 BTU/h input, 96% AFUE two-stage furnace.

418 words, about 2 min