KY HVAC study materials
KY HVAC study resources

KY HVAC study plan

KY HVAC · Give each week a clear focus.

8 weeks · About 7 hours per week

Week 1

Refrigeration Principles and System Components

  • Trace the vapor-compression cycle on paper and label pressure, temperature, and phase at all four state points (compressor in/out, condenser out, metering device out, evaporator out)

  • Compute superheat and subcooling from gauge and thermometer readings for 10 practice scenarios without a calculator shortcut sheet

  • Match each major component (compressor, condenser, evaporator, metering device, filter-drier, accumulator, receiver, reversing valve) to its function and its top three failure symptoms

  • Read a pressure-temperature chart for three common refrigerants and convert saturation pressures to temperatures in both directions

Your checkpoint

One-page hand-drawn system diagram with labeled state points plus a completed 10-problem superheat/subcooling worksheet scored at 80% or better

Week 2

Refrigeration Principles and System Components & Heating Equipment and Combustion Safety

  • Diagnose five refrigeration-side faults (overcharge, undercharge, restriction, non-condensables, inefficient compressor) from combined suction pressure, head pressure, superheat, and subcooling readings

  • Explain combustion fundamentals in writing: the fire triangle, stoichiometric air, excess air, and the difference between complete and incomplete combustion products

  • Write out the gas-furnace sequence of operation from thermostat call for heat through blower off-delay, naming each switch and safeties in order

  • Convert and interpret draft and gas-pressure readings between inches of water column and pounds per square inch

Your checkpoint

A fault-symptom matrix (5 faults x 4 readings) plus a numbered gas-furnace sequence-of-operation checklist with every safety device named

Week 3

Heating Equipment and Combustion Safety

  • Calculate combustion and ventilation air requirements for a stated appliance input rating using code tables and the two-opening method

  • Classify appliances by venting category and list the installation defects that cause spillage or backdrafting

  • Interpret a combustion analysis report (O2, CO2, CO air-free, stack temperature, steady-state efficiency) and state the corrective action for each out-of-range value

  • Describe carbon monoxide exposure symptoms and the required technician response on a CO alarm or failed draft test

  • Perform a gas piping leak test and size a branch line from an appliance input rating and length of run

Your checkpoint

A five-case combustion analysis set with a written diagnosis and corrective action for each, plus a combustion-air sizing worksheet for two appliances

Week 4

Air Distribution, Ventilation, and Indoor Air Quality

  • Size a trunk-and-branch duct system by the equal-friction method and record the friction rate and velocity for each run

  • Measure external static pressure on a system and plot it against a fan table to determine actual delivered airflow

  • Calculate whole-house ventilation airflow using the ASHRAE 62.2 formula for a stated floor area and bedroom count, then select a fan

  • Identify the source, health effect, and control strategy for mold, carbon monoxide, radon, VOCs, combustion byproducts, and particulates

  • Explain how duct leakage, return location, and pressure imbalance affect infiltration and IAQ

Your checkpoint

A one-zone duct layout drawing with a complete sizing table, plus a 62.2 ventilation calculation and fan selection write-up

Week 5

Electrical Systems, Motors, and Controls

  • Trace a heating control circuit and a cooling control circuit on a ladder diagram and annotate every load and switch

  • Measure and interpret voltage, current, resistance, and capacitance safely on both energized and de-energized circuits

  • Differentiate PSC, ECM, and variable-speed motors and their start components, then diagnose an open winding and a failed run capacitor

  • Explain motor overload protection and the logic of the thermostat, control board, relays, limits, and pressure switches in a call sequence

  • Size a conductor and fuse/breaker for a stated minimum circuit ampacity and maximum overcurrent protection

Your checkpoint

A hand-drawn furnace control ladder diagram reproduced from memory with a 20-question electrical troubleshooting set scored at 80% or better

Week 6

Load Calculation, Sizing, and System Design

  • Perform a room-by-room heat loss and heat gain using Manual J principles, including envelope areas, U-factors, and infiltration allowance

  • Separate sensible and latent loads and check the selected equipment against cfm-per-ton and sensible heat ratio targets

  • Convert calculated loads into equipment selection and document the safety margin and any oversizing risk

  • Size refrigerant lines and the supply trunk for the selected system using manufacturer tables

Your checkpoint

A completed load calculation worksheet for a sample 1,800 sq ft single-story house with an equipment selection summary and cfm-per-ton verification

Week 7

Codes, Permits, and Business/Regulatory Practices & Refrigeration Principles and System Components

  • Locate Kentucky's HVAC contractor and technician licensing, permit, and inspection requirements from the state authority having jurisdiction and summarize the steps

  • Apply refrigerant handling rules (Section 608 certification, recovery and recycling, leak repair thresholds, recordkeeping) to written scenario questions

  • List mechanical code requirements for appliance clearances, condensate disposal, and access panels, and check a sample installation against them

  • Build a job estimate that includes labor, material, overhead, profit, and change-order language, and explain lien and liability basics

Your checkpoint

A one-page compliance checklist covering permits, refrigerant handling, and mechanical-code clearances, plus a sample bid with itemized overhead and profit

Week 8

Refrigeration Principles and System Components & Heating Equipment and Combustion Safety & Air Distribution, Ventilation, and Indoor Air Quality & Electrical Systems, Motors, and Controls & Load Calculation, Sizing, and System Design & Codes, Permits, and Business/Regulatory Practices

  • Complete two full-length timed practice exams under test conditions and log every missed item by domain

  • Re-drill the three weakest objectives until targeted practice sets reach 85% or better

  • Rebuild a one-page formula sheet covering superheat and subcooling, cfm from Btu/h and temperature difference, combustion air, and ventilation rate

  • Confirm exam-day logistics, identification, and any license application paperwork still outstanding

Your checkpoint

A categorized error log of 40 or more missed items with a corrective action for each, plus a final mock exam score of 80% or better

Milestones

Week 2: Can explain the full vapor-compression cycle and diagnose all five common charge and restriction faults from four readings without notes

Week 4: Can pass a self-made 25-question quiz on combustion safety and venting at 80% or better, including one full combustion analysis interpretation

Week 5: Can read a ladder diagram cold and correctly diagnose a no-heat call and a no-cool call on paper within 10 minutes each

Week 6: Load calculation worksheet is complete, equipment selected matches the sensible and latent loads, and cfm-per-ton falls within range

Week 8: Two timed practice exams completed, error log fully categorized, and every domain at 80% or better on targeted retests