Integrative Process

  • In LEED v4 BD+C the Integrative Process is a 1-point credit; in LEED v4.1 BD+C it is elevated to a prerequisite (IPp1).

  • The credit requires two analyses completed before the end of schematic design: energy-related systems and water-related systems.

  • The energy analysis must compare at least two optional energy-related measures against a baseline using a simple box massing model.

  • The water analysis must use a simple water budget covering indoor demand, outdoor irrigation demand, process water, and supply sources.

  • Integrative process outcomes feed the Owner's Project Requirements (OPR) and Basis of Design (BOD), which are the foundation documents for commissioning.

  • The discovery-phase charrette convenes owner, architects, engineers, contractor, and operations/facilities staff before design decisions are locked in.

  • Influence over cost and performance peaks at pre-design and schematic design; the ability to change the project declines sharply after design development.

  • Typical synergies: daylighting reduces lighting power density, which reduces cooling load, which reduces HVAC capacity and first cost.

Quick reference

Location and Transportation

  • LEED v4 BD+C has no prerequisites in the Location and Transportation category; all LT credits are optional points.

  • LEED for Neighborhood Development location awards up to 16 points, the largest single credit value in the rating system.

  • Access to Quality Transit: main entrance within 1/4-mile walking distance of bus or BRT stops, or 1/2-mile of rail or ferry stations.

  • Surrounding Density and Diverse Uses: combined density of at least 25,000 sq ft/acre of buildable land, or at least 7 diverse uses within 1/2-mile walking distance.

  • Bicycle Facilities: short-term bicycle storage for 2.5% of peak visitors, long-term storage for 5% of regular building occupants, plus shower and changing facilities.

  • High Priority Site: brownfield, site in a distressed or low-income community, or infill site adjacent to existing development.

  • Reduced Parking Footprint: parking capacity at or below the local zoning minimum, with preferred spaces for carpools and green vehicles.

  • Sensitive Land Protection: avoid development on prime farmland, floodplains, habitat for threatened or endangered species, and within 100 ft of wetlands.

Quick reference

Sustainable Sites

  • Construction Activity Pollution Prevention is the only Sustainable Sites prerequisite: an erosion and sedimentation control plan meeting the EPA Construction General Permit or stricter local equivalent.

  • The Site Assessment credit requires evaluation of topography, hydrology, climate, vegetation, soils, human health effects, and adjacent properties before design begins.

  • Protect or Restore Habitat limits site disturbance to 40 ft beyond the building footprint and 25 ft beyond hardscape, or restores native vegetation on 20% of site area.

  • Open Space: outdoor space at least 30% of total site area, with at least 25% of that space vegetated.

  • Rainwater Management: replicate natural hydrology by managing on site the runoff from the 95th percentile rainfall event (80th percentile in combined sewer areas).

  • Heat Island Reduction: nonroof measures on 50% of hardscape (solar reflectance 0.28 or shaded) and roof measures on 75% of roof area using high-SRI or vegetated roofing.

  • Light Pollution Reduction uses BUG (backlight, uplight, glare) ratings and light trespass limits from IES to control skyglow and spill onto adjacent sites.

Quick reference

Water Efficiency

  • LEED v4 BD+C Water Efficiency prerequisites: Outdoor Water Use Reduction (30% below baseline), Indoor Water Use Reduction (20% below baseline), and Building-Level Water Metering.

  • The indoor fixture baseline is derived from EPAct 1992 flow and flush rates; design case uses WaterSense-labeled or equivalent fixtures and fittings.

  • The outdoor irrigation baseline is generated by the EPA WaterSense Water Budget Tool using local evapotranspiration and precipitation data.

  • Percentage reduction formula: (baseline water use − design case water use) ÷ baseline water use × 100.

  • Captured rainwater, graywater, and recycled water used for irrigation or toilet flushing count toward the design-case reduction.

  • The Outdoor Water Use Reduction credit awards additional points up to 50% reduction; the Indoor Water Use Reduction credit awards up to 6 points.

  • Cooling Tower Water Use limits potable water consumed by towers by setting maximum cycles of concentration based on makeup water quality.

  • Occupancy assumptions matter: the indoor water calculator uses FTE occupants and peak transient occupants with default or project-specific durations of use.

Quick reference

Energy and Atmosphere

  • LEED v4 BD+C Energy and Atmosphere prerequisites: Fundamental Commissioning and Verification, Minimum Energy Performance, Building-Level Energy Metering, and Fundamental Refrigerant Management.

  • Minimum Energy Performance uses ASHRAE 90.1-2010 as the baseline in LEED v4 (90.1-2016 in LEED v4.1) and requires whole-building energy simulation or the prescriptive AEDG compliance path.

  • Optimize Energy Performance is worth up to 18 points, scored on a sliding scale from 6% improvement over baseline (1 point) to 50% improvement (18 points).

  • Energy use intensity (EUI) = annual site energy consumption in kBtu ÷ gross floor area in square feet; source EUI converts site energy using site-to-source factors.

  • Fundamental Commissioning requires an independent commissioning authority to review OPR and BOD, write the Cx plan, verify installation, perform functional testing, and deliver a systems manual plus training.

  • Enhanced Commissioning adds design-phase review, contractor submittal review, and a post-occupancy review within 10 months of substantial completion.

  • Advanced Energy Metering requires end-use level metering of electricity, gas, and water with data recorded at one-hour intervals or less and reported monthly.

  • Fundamental Refrigerant Management prohibits CFC-based refrigerants in new HVAC&R systems and requires a phase-out plan where existing CFC equipment remains.

Quick reference

Materials and Resources

  • LEED v4 BD+C Materials and Resources prerequisites: Storage and Collection of Recyclables and Construction and Demolition Waste Management Planning.

  • The recyclables area must serve the entire building and accommodate paper, corrugated cardboard, glass, plastics, and metals for the life of the building.

  • Construction and Demolition Waste Management: 50% diversion of nonhazardous waste earns 1 point, 75% earns 2 points; waste-to-energy does not count as diverted.

  • Building Life-Cycle Impact Reduction offers options including historic building reuse, renovation of blighted buildings, salvage of 75% of existing structure and envelope, and whole-building LCA.

  • Whole-building LCA must show at least 10% reduction in three of six impact categories compared with a functionally equivalent baseline building.

  • Building Product Disclosure and Optimization - EPD: 20 different permanently installed products from at least 5 different manufacturers with environmental product declarations.

  • Material Ingredients credit requires chemical inventory reporting for 20 products from at least 5 manufacturers, or a documented material ingredient optimization path.

  • A product with a third-party verified EPD discloses life-cycle impacts such as global warming potential, ozone depletion, acidification, eutrophication, and smog formation.

Quick reference

Indoor Environmental Quality

  • LEED v4 BD+C Indoor Environmental Quality prerequisites: Minimum Indoor Air Quality Performance (ASHRAE 62.1-2010), Environmental Tobacco Smoke Control, and Minimum Acoustic Performance for schools.

  • Environmental Tobacco Smoke Control prohibits smoking inside the building and within 25 ft of entries, operable windows, and outdoor air intakes.

  • Low-Emitting Materials credit covers seven categories, with VOC limits based on CDPH Standard Method v1.1-2010 and CARB ATCM for composite wood.

  • The Construction Indoor Air Quality Management Plan follows SMACNA guidelines: protect stored absorptive materials, use MERV 8 filters during construction and MERV 13 before occupancy.

  • The IAQ Assessment flush-out path requires 14,000 cu ft of outdoor air per sq ft of floor area delivered after construction and before occupancy.

  • Post-construction air testing thresholds include formaldehyde at or below 27 ppb and total volatile organic compounds at or below 500 micrograms per cubic meter.

  • Daylight credit: spatial daylight autonomy of 300 lux for 50% of occupied hours across 55% of floor area, with annual sunlight exposure limited to 10% of area.

  • Quality Views: direct line of sight to the outdoors from 75% of the regularly occupied floor area, excluding views to blank walls or fence lines.

Quick reference

Innovation

  • The Innovation credit is worth a maximum of 6 points, one of which may be earned by having a LEED Accredited Professional with a specialty on the project team.

  • Innovation points are earned for measurable environmental performance using a strategy not addressed by any existing credit in the rating system.

  • Exemplary performance awards Innovation points when a project doubles a credit's threshold or reaches a defined upper tier stated in the rating system.

  • Approved pilot credits from the LEED pilot credit library may be attempted and, if achieved, counted toward Innovation points.

  • Each Innovation claim requires a written narrative describing the approach, the metric used, and the documentation verifying the outcome.

  • Innovation strategies cannot be duplicative: a strategy already counted in an existing credit cannot also earn an Innovation point.

Quick reference

Regional Priority

  • Regional Priority credits are worth a maximum of 4 bonus points in a LEED BD+C project.

  • USGBC designates six Regional Priority credits for each zip code, based on the environmental priorities of that region.

  • A Regional Priority point is awarded only if the underlying credit is also achieved in the same project; it functions as a bonus multiplier.

  • Typical regional priorities include water conservation in arid regions, air quality in nonattainment areas, and habitat protection in ecologically sensitive zones.

  • Regional Priority credit selections are determined at registration by the project's zip code and cannot be freely chosen by the project team.

  • Because only four of the six designated credits can be claimed, projects typically pursue the four that align with their design strategy.

Quick reference

Project Surroundings and Public Outreach

  • Community outreach is conducted during pre-design so that neighbors and stakeholders can influence site layout, access, and mitigation measures before permits are filed.

  • Site selection screening evaluates previously developed land, proximity to transit, prime farmland, floodplains, wetlands within 100 ft, and habitat for threatened species.

  • Transportation demand management measures such as transit passes, carpool programs, and bicycle infrastructure reduce vehicle miles traveled by building occupants.

  • Light pollution reduction controls skyglow, light trespass onto neighboring properties, and glare through fixture shielding, curfews, and BUG-rated luminaires.

  • Construction-period outreach addresses dust, noise, idling, haul routes, and erosion control, and often is formalized in a good-neighbor agreement.

  • Public education signage or a green building education program can communicate sustainable features to occupants and the surrounding community.

  • Adjacent property impacts analyzed during site assessment include shadowing, wind, noise, and views, which inform massing and landscape buffers.