IESL Part II Electrical study materials
IESL Part II Electrical study resources

IESL Part II Electrical key terms

IESL Part II Electrical · Get comfortable with the vocabulary.

Power factor

The ratio of real power in watts to apparent power in volt-amperes in an alternating-current circuit, ranging from zero to one and indicating how effectively current does useful work.

Related: Apparent power, Reactive power, Power factor correction
Apparent power

The product of root-mean-square voltage and root-mean-square current in an AC circuit, measured in volt-amperes, representing the total power that appears to flow before phase difference is considered.

Related: Power factor, Reactive power
Reactive power

The portion of apparent power that oscillates between source and reactive elements such as inductors and capacitors without being consumed, measured in volt-amperes reactive and linked to magnetic or electric field energy.

Related: Power factor, Apparent power
Power factor correction

The addition of capacitors or other compensating devices to an inductive load so that the phase angle between voltage and current is reduced, lowering apparent power drawn and avoiding utility penalty charges.

Related: Power factor, Reactive power
Per-unit system

A method of expressing voltages, currents, impedances and powers as fractions of chosen base values, simplifying transformer networks and fault calculations by removing turns-ratio conversions between voltage levels.

Related: Fault level, Symmetrical components
Symmetrical components

A technique that resolves an unbalanced three-phase set of phasors into three balanced sets called positive, negative and zero sequence, enabling separate analysis of unbalanced faults and machine behaviour.

Related: Per-unit system, Earth fault loop impedance
Earth fault loop impedance

The total impedance of the path taken by fault current from the source through the live conductor, the fault, the protective conductor and back to the source, determining whether overcurrent protection will disconnect quickly.

Related: Symmetrical components, Residual current device
Residual current device

A protective switch that continuously compares live and neutral currents and trips when their difference exceeds a set threshold, detecting leakage to earth that ordinary overcurrent devices may not clear.

Related: Earth fault loop impedance, Protective earth conductor
Protective earth conductor

A conductor that connects exposed conductive parts of equipment to the earthing system so that fault current returns safely and protective devices operate before dangerous touch voltages persist.

Related: Residual current device, Earthing electrode
Earthing electrode

A buried conductor, rod or plate that makes direct electrical contact with the soil and provides a low-resistance path to earth for fault current and lightning discharge.

Related: Protective earth conductor, Step potential
Step potential

The voltage difference appearing between two points on the ground surface one metre apart during a fault current discharge, which can drive dangerous current through a person's legs standing nearby.

Related: Earthing electrode, Touch potential
Touch potential

The voltage difference between an earthed metallic structure and a point on the ground a person can touch simultaneously, which determines the shock hazard from a faulted installation.

Related: Step potential, Earthing electrode
Diversity factor

The ratio of the sum of individual maximum demands to the maximum demand of the whole installation, used to size supply equipment realistically because not all loads peak simultaneously.

Related: Load factor, Demand factor
Load factor

The average load over a period divided by the peak load in that period, indicating how efficiently installed capacity is used and influencing tariffs and generation planning.

Related: Diversity factor, Demand factor
Demand factor

The ratio of the maximum demand of a system to its total connected load, used in installation design to estimate realistic maximum current drawn from all connected equipment.

Related: Diversity factor, Load factor
Skin effect

The tendency of alternating current to concentrate near the surface of a conductor as frequency rises, increasing effective resistance and reducing the useful cross-section for high-frequency or large conductor applications.

Related: Proximity effect, Corona discharge
Proximity effect

The redistribution of current in a conductor caused by the magnetic field of a nearby parallel conductor, raising effective resistance in closely spaced cables and busbars at power frequencies.

Related: Skin effect
Corona discharge

A partial electrical breakdown of air around high-voltage conductors where the local electric field exceeds the breakdown strength, producing audible hiss, ozone and radio interference that waste energy.

Related: Skin effect, Surge arrester
Surge arrester

A protective device that presents high impedance at normal voltage but conducts heavily during overvoltage transients, diverting lightning or switching surges to earth and then restoring normal operation.

Related: Corona discharge, Basic impulse level
Basic impulse level

The peak impulse voltage a piece of insulation can withstand without breakdown under a standard lightning impulse waveform, used to coordinate insulation strength with protective device levels.

Related: Surge arrester
Buchholz relay

A gas-actuated protective device fitted in the pipe between a transformer tank and its conservator, detecting gas accumulation from incipient faults and tripping on severe oil surge.

Related: Differential protection, Tap changer
Differential protection

A scheme that compares currents entering and leaving a protected zone and trips when the difference exceeds a setting, giving fast selective clearing of internal faults in transformers, generators and busbars.

Related: Buchholz relay, Current transformer
Tap changer

A mechanism that alters the number of turns in a transformer winding to adjust its voltage ratio, either offline or on load, compensating for supply voltage variation and controlling network voltage.

Related: Buchholz relay, Per-unit system
Current transformer

An instrument transformer that reproduces a large primary current as a proportional, phase-related smaller secondary current for metering and protection relays while isolating them from high voltage.

Related: Differential protection, Burden
Burden

The total impedance of the connected secondary circuit, including relays, meters and wiring, that a current or voltage transformer must drive while staying within its accuracy limits.

Related: Current transformer
Nyquist criterion

A stability test for feedback systems that judges closed-loop stability from the open-loop frequency response by counting encirclements of the minus-one point in the complex plane.

Related: Bode plot, Phase margin
Bode plot

A pair of graphs showing the magnitude and phase of a system's frequency response against logarithmic frequency, used to read gain and phase margins and assess relative stability.

Related: Nyquist criterion, Phase margin
Phase margin

The amount by which the open-loop phase exceeds minus one hundred eighty degrees at the frequency where open-loop gain crosses unity, indicating how much additional delay the loop can tolerate.

Related: Bode plot, Nyquist criterion
PID controller

A feedback controller that sums proportional, integral and derivative actions on the error signal, where integral action removes steady-state offset and derivative action adds damping and speed of response.

Related: Phase margin, Root locus
Root locus

A plot of the paths traced by closed-loop poles in the complex plane as a system parameter, usually gain, varies from zero to infinity, revealing stability and transient response trends.

Related: PID controller, Nyquist criterion
Z-transform

The discrete-time counterpart of the Laplace transform, converting a sampled sequence into a function of a complex variable so that difference equations can be analysed algebraically.

Related: Aliasing, Sampling theorem
Sampling theorem

The principle that a signal band-limited to a highest frequency must be sampled at more than twice that frequency to be reconstructed exactly from its samples.

Related: Aliasing, Z-transform
Aliasing

The distortion that occurs when a signal is sampled below twice its highest frequency, causing high-frequency components to appear falsely as lower frequencies in the reconstructed signal.

Related: Sampling theorem, Anti-aliasing filter
Anti-aliasing filter

A low-pass filter placed before an analogue-to-digital converter that removes frequency content above half the sampling rate so that aliasing cannot occur.

Related: Aliasing, Sampling theorem
Modulation index

A dimensionless measure of how strongly a carrier is varied by the modulating signal; in amplitude modulation it is the ratio of modulating amplitude to carrier amplitude, and values above one cause overmodulation.

Related: Frequency deviation, Quantisation noise
Frequency deviation

The peak difference between the instantaneous frequency of a frequency-modulated carrier and its unmodulated centre frequency, governing bandwidth and signal-to-noise performance.

Related: Modulation index
Quantisation noise

The error introduced when a continuous amplitude is rounded to the nearest discrete level in digitisation, heard as a low-level hiss whose power falls as bit depth increases.

Related: Anti-aliasing filter, Modulation index
Characteristic impedance

The ratio of voltage to current for a wave travelling along a uniform transmission line, determined by the line's inductance and capacitance per unit length and independent of line length.

Related: Standing wave ratio, Reflection coefficient
Standing wave ratio

The ratio of maximum to minimum voltage or current magnitude along a transmission line carrying a standing wave, indicating the degree of mismatch between line and load.

Related: Characteristic impedance, Reflection coefficient
Reflection coefficient

The complex ratio of the reflected wave amplitude to the incident wave amplitude at a discontinuity, whose magnitude and phase determine how much power returns toward the source.

Related: Standing wave ratio, Characteristic impedance