SLIA Part I study materials
SLIA Part I study resources

SLIA Part I cheat sheet

SLIA Part I · Keep the key ideas within reach.

Quick reference

Architectural History and Theory

  • Vitruvius's triad - firmitas (structure), utilitas (function), venustas (beauty) - remains the canonical test applied to any building in theory questions.

  • Classical orders by proportion: Doric (1:7), Ionic (1:9), Corinthian (1:10) column height-to-diameter ratios, with the Tuscan simplest and Composite combining Ionic volute with Corinthian acanthus.

  • Pugin's True Principles (1841) and Ruskin's Seven Lamps (1849) anchor the Gothic Revival argument that structural honesty and craft are moral, not merely aesthetic, requirements.

  • Modernism's canonical statements: Sullivan's 'form follows function', Loos's 'Ornament and Crime' (1908), Le Corbusier's Five Points (pilotis, free plan, free facade, ribbon windows, roof garden).

  • CIAM's Athens Charter (1933) codified functional zoning (dwelling, work, recreation, circulation); Team X rejected it in the 1950s for lost street life and urban complexity.

  • Postmodernism (Venturi, Scott Brown, Jencks) replaced modernist purity with double coding, historic quotation, and the decorated shed versus the duck.

  • Phenomenology in architecture (Heidegger's dwelling, Pallasmaa's eyes of the skin) argues embodied sensory experience and materiality precede visual composition.

  • Critical regionalism (Frampton, 1983) resists both placeless universal technique and nostalgic pastiche through tectonics rooted in climate and topography.

Quick reference

Building Technology and Construction

  • Thermal transmittance U = 1/R_total; total R is the sum of layer resistances plus surface films (interior ≈ 0.13 m²K/W, exterior ≈ 0.04 m²K/W in still air).

  • Concrete characteristic cube strength fck relates to design value by fcd = αcc·fck/γc, with γc typically 1.5 (EC2) and 0.85 for sustained-load αcc.

  • Reinforcement cover is measured to the outer bar; durability exposure class, not member size, sets minimum cover, and fire resistance adds a separate axis-distance check.

  • Steel beams: plastic moment capacity Mpl = Wpl·fy/γM0; deflection limits (often span/250 or span/360) usually govern long-span serviceability.

  • Timber design uses modification factor kmod for load duration and moisture, plus kdef for long-term creep; service classes 1–3 reflect moisture exposure.

  • Moisture control rule: the vapour control layer goes on the warm side; insulation must not be sandwiched where interstitial condensation can form below dew point.

  • Concrete curing: 7 days for CEM I at 20 °C is the common minimum; cold weather below 5 °C requires insulated formwork and temperature monitoring.

  • Fire resistance is expressed in minutes (R for loadbearing, E for integrity, I for insulation); compartmentation limits spread, and protected escape routes are a separate requirement.

Quick reference

Professional Practice

  • Standard fee stages follow work stages: inception/feasibility, concept, developed design, technical design, tender, construction, and post-occupancy, each with defined deliverables.

  • Architect's authority is limited: the architect certifies and administers but does not guarantee the contractor's work, and must act fairly when certifying.

  • Instructions must be in writing; oral instructions should be confirmed in writing within a defined period or they are not binding.

  • Practical completion transfers possession and risk, starts the defects liability period (commonly 12 months), and releases half the retention (often 3% of 5%).

  • Variations require written instruction or confirmation; valuation follows rates in the contract, then fair valuation, then a quotation.

  • Professional indemnity insurance is claims-made, so cover must be maintained for the limitation period after the project ends; aggregate limits apply per claim or per year.

  • Time bars: notice of delay, extension-of-time claims, and final account submissions each carry contractual deadlines; missing them can extinguish entitlement.

  • A letter of intent creates limited authority to proceed before contract execution and should cap scope, fee, and duration explicitly.

Quick reference

Law and Ethics

  • Negligence requires duty of care, breach, causation, and damage; professional standard is the ordinary skill of a reasonably competent practitioner in that field.

  • Contractual duties are stricter than tort duties: a contractual obligation to achieve a result can be breached without negligence.

  • Codes of conduct typically require competence, honesty, integrity, respect for others, and public-interest regard; conflicts of interest must be declared and managed.

  • Copyright in drawings and design arises automatically on creation; the client usually receives a licence for the project, not ownership of the copyright.

  • Statutes of limitation: contract claims commonly 6 years (12 under deed), tort claims 6 years from damage with a 15-year longstop in many jurisdictions.

  • Collateral warranties give funders and tenants direct contractual rights against the architect, avoiding reliance on tortious duty alone.

  • Health and safety duties are non-delegable in many jurisdictions; the designer must eliminate foreseeable hazards and provide information for safe construction.

  • Bribery, facilitation payments, and undisclosed referral fees breach professional ethics regardless of local custom; record and refuse.

Quick reference

Design

  • Accessibility: a 1:12 ramp is the steepest common limit, with landings at intervals; door clear widths and turning circles (typically 1.5 m) are the operative dimensions.

  • Means of escape: travel distance limits depend on occupancy and sprinkler provision; two directions of escape are required beyond a threshold occupancy.

  • Daylight factor = (internal illuminance / external horizontal illuminance) × 100; useful rules of thumb target 2% average and 0.5–1% minimum over the working plane.

  • Stair geometry: 2R + G = 550–700 mm; riser ≤ 190 mm and going ≥ 250 mm are common public-building limits, with headroom ≥ 2 m.

  • Space planning: net-to-gross efficiency of 75–85% is typical for offices; structural grid usually drives column-free depth of 9–12 m.

  • Universal design principles: equitable use, flexibility, simple intuitive use, perceptible information, tolerance for error, low physical effort, size and space for approach.

  • Acoustic separation: airborne sound insulation depends on mass and airtightness; flanking paths often govern more than the separating element itself.

  • Fire engineering: occupancy load factors (m² per person) convert floor area to design population, which then sets exit widths and stair numbers.

Quick reference

Environment and Sustainability

  • Operational energy dominates whole-life carbon in most buildings; embodied carbon (A1–A5 modules) is significant for new construction and structure choice.

  • Whole-life carbon modules: A1–A3 product, A4–A5 construction, B1–B7 use and maintenance, C1–C4 end of life, D beyond system boundary benefits.

  • Heat loss: fabric transmission plus ventilation/infiltration; airtightness measured in m³/(h·m²) at 50 Pa, with 3–5 typical for good dwellings and <1 for passive.

  • Passive design priority order: reduce demand (form, orientation, insulation, airtightness), then supply efficiently, then renewables.

  • Overheating risk grows with glazing ratio and internal gains; solar control (shading coefficient, g-value) is more effective than added cooling capacity.

  • Renewable options: heat pumps (COP 3–4), solar thermal, PV (roughly 150–200 W/m² installed output), and district heating where density allows.

  • Water: low-flow fittings, rainwater harvesting, and SUDS (attenuation, permeable paving) reduce potable demand and runoff; greywater recycling needs treatment.

  • Green certification schemes (BREEAM, LEED, WELL) score different things: environmental performance, energy and carbon, and human health respectively.