Luxembourg CCDL Exam study materials
Luxembourg CCDL Exam study resources

Luxembourg CCDL Exam cheat sheet

Luxembourg CCDL Exam · Keep the key ideas within reach.

Quick reference

Legal and Regulatory Framework for Housing in Luxembourg

  • Loi du 25 février 1979 sur le logement: defines social housing (logement social) and the role of the SNHBM and communes in subsidised rental and acquisition schemes.

  • Loi du 21 septembre 2006 sur le bail à usage d'habitation: governs residential leases, notice periods (3 months for tenant, 6 months for landlord with justification), and limits on deposits (max 2 months' rent, returned within 1 month of handover).

  • Loi du 8 septembre 1998 (bail commercial) does NOT apply to dwellings; misclassification of a residential lease as commercial is void against the tenant.

  • Bail à usage d'habitation must be in writing, state surface area and number of rooms (loi 2006), and include an état des lieux (inventory) at entry and exit.

  • Rent indexation is tied to the consumer price index (échelle mobile); a rent increase requires 3 months' written notice and cannot exceed the index adjustment.

  • Loi du 22 octobre 2008 on the impôt foncier and the taxe sur la valeur ajoutée (TVA) at 3% super-reduced rate applies to certain owner-occupied principal residences (conditions: single dwelling, minimum surface, completion within deadline).

  • Loi du 19 juillet 2004 (Code du travail) and loi du 7 août 2023 on the protection of tenants: eviction requires a court order; winter truce (trêve hivernale) from 1 November to 15 March restricts enforcement.

  • Copropriété: loi du 16 mai 1975 (as amended) governs co-ownership, mandatory syndic, general assembly voting majorities (art. 13: 3/4 for structural works, unanimity for change of destination).

Quick reference

Urban Planning and Land-Use Rules (Aménagement du Territoire, PAP/PAG)

  • Loi du 30 juillet 2013 concernant l'aménagement du territoire: hierarchy of plans - Programme directeur (national), plans directeurs régionaux, PAG (plan d'aménagement général, communal), PAP (plan d'aménagement particulier, project-level).

  • PAG (Plan d'Aménagement Général) replaced the former PAG/POS system; it defines zones (habitat, mixte, activités économiques, agricole, forestier, verdure, etc.) and is adopted by the commune after public enquiry and ministerial approval.

  • PAP (Plan d'Aménagement Particulier) must be compatible with the PAG; two types - PAP 'quartier existant' (existing fabric) and PAP 'nouveau quartier' (new development). PAP requires a convention with the commune for infrastructure.

  • COS (coefficient d'occupation du sol) and CUS (coefficient d'utilisation du sol) are set in the PAG/PAP; COS = footprint/plot area; CUS = gross floor area/plot area.

  • Superficie d'emprise au sol (footprint) and superficie de plancher (gross floor) are distinct; only the latter counts toward CUS.

  • Servitudes urbanistiques (setbacks, building lines, height limits) are registered in the PAG/PAP and bind subsequent owners; they run with the land.

  • Loi du 28 juillet 2011 (as amended) on the Pacte logement: communes receive subsidies for creating housing; the Pacte logement 2.0 (2023) links funding to densification targets.

  • Modification of a PAG requires: communal council vote, public enquiry (enquête publique) of 30 days, ministerial approval; a PAP requires a similar but shorter procedure.

Quick reference

Building Permits and Administrative Procedures

  • Loi du 19 juillet 2004 (as amended) on the organisation of construction (loi sur l'aménagement communal et le développement urbain) requires a permis de construire (building permit) for new construction, substantial alteration, change of use, and certain demolition.

  • Application is submitted to the commune; the commune has 3 months (extendable) to decide; silence beyond the legal period does not equal approval - explicit authorisation is required.

  • Permis d'aménagement (PAP) and permis de construire are distinct; a PAP must be approved before a building permit can be granted for a new development.

  • Commissions: Commission des sites et monuments nationaux (for listed/heritage buildings), Commission consultative (communal), and the Ministère de l'Intérieur for appeals.

  • Recours: appeal against a refusal is lodged with the Conseil d'État (administrative jurisdiction) within 3 months of notification; an appeal suspends neither the works nor the decision unless a référé-suspension is granted.

  • Déclaration préalable (notification) is required for minor works (fences, small extensions below thresholds set by communal règlement); it is not a permit.

  • Certificat d'urbanisme (certificate of urbanism) is a non-binding information document issued by the commune stating applicable planning rules for a plot.

  • Récolement (final inspection) and conformity certificate: works must conform to the permit; unauthorised works can be ordered to be demolished or regularised under the loi du 19 juillet 2004.

Quick reference

Building Physics, Energy Performance and Sustainability

  • Loi du 23 décembre 2016 (as amended) on energy performance of buildings (performance énergétique des bâtiments, PEB) transposes the EPBD; applies to new buildings and major renovations.

  • PEB certificate (certificat de performance énergétique) is mandatory for new buildings, sale, and rental; classes range from A to I; the certificate is valid 10 years.

  • Nearly zero-energy building (nZEB / bâtiment à consommation quasi nulle) is mandatory for new buildings from 2021 (public) / 2023 (private).

  • Key U-values (residential, W/m²K): roof ≤ 0.15, external wall ≤ 0.20, floor on ground ≤ 0.25, windows ≤ 1.10 (Uw); thermal bridging must be limited (ψ ≤ 0.01 W/mK).

  • K-value (coefficient de transmission thermique global) for residential ≤ 0.30 W/m³K (new build); airtightness n50 ≤ 1.5 h⁻¹ for nZEB.

  • Summer comfort: overheating risk assessed; solar factor (g-value) of glazing ≤ 0.35 for south-facing; external shading recommended.

  • Moisture: Glaser method for interstitial condensation; vapour barrier on warm side; capillary break at floor-wall junction.

  • Circular economy and sustainability: LCA (analyse du cycle de vie) increasingly required; use of renewable energy (heat pumps, solar thermal/PV) and rainwater harvesting supported by subsidies.

Quick reference

Structural Design and Construction Techniques

  • Eurocodes apply in Luxembourg: EN 1990 (basis), EN 1991 (actions), EN 1992 (concrete), EN 1993 (steel), EN 1995 (timber), EN 1996 (masonry), EN 1998 (seismic). National Annexes (ANL) adopted.

  • Seismic: Luxembourg is in zone 0/low seismicity; EN 1998-1 with national annex; design ground acceleration ag ≤ 0.04g for most of the territory - nominal seismic design for ordinary buildings.

  • Snow load: sk ≤ 0.8 kN/m² at ground for altitudes < 300 m; wind: basic velocity vb,0 ≈ 24 m/s (terrain categories per EN 1991-1-4).

  • Imposed loads (EN 1991-1-1): residential floors qk = 1.5 kN/m², stairs 3.0 kN/m², balconies 2.5 kN/m² (categories A, B).

  • Concrete: C25/30 minimum for reinforced concrete in normal exposure (XC1); cover cnom = cmin + Δcdev (Δcdev = 10 mm typical).

  • Timber: EN 1995-1-1; service classes 1-3; kdef for deflection; connections per EN 1995-1-1 §8.

  • Masonry: EN 1996; characteristic compressive strength fk from unit and mortar; slenderness ratio limits.

  • Foundations: Luxembourg geology - Luxembourg Sandstone (Lias) in the centre/east, schist and quartzite in the Ardennes (Oesling); geotechnical investigation per EN 1997 required before foundation design.

Quick reference

Building Services and Technical Installations

  • Heating: EN 12831 load calculation; condensing boilers with seasonal efficiency ≥ 90%; heat pumps (air-water, ground-source) encouraged under PEB.

  • Ventilation: EN 13141/EN 13779; residential mechanical extract ventilation (VMC) minimum 0.3 air changes per hour; nZEB requires demand-controlled ventilation with heat recovery (η ≥ 80%).

  • Domestic hot water: solar thermal with min. 50% coverage for new residential buildings (PEB requirement); legionella prevention - store at ≥ 60 °C, distribute at ≥ 50 °C.

  • Electrical: RGIE/AREI (règlement général des installations électriques) applies; differential protection 30 mA for socket circuits; earthing per TN system.

  • Gas: installation per EN 1775; gas certificate required; annual inspection.

  • Fire safety installations: smoke detectors mandatory in dwellings (loi du 8 juin 2004); detection in common areas of apartment buildings.

  • Lifts: EN 81-20/50; inspection every 12 months by an approved body (Sécurité-Santé au travail / ITM).

  • Rainwater and greywater: separate networks; infiltration encouraged; rainwater harvesting for WC and garden permitted with backflow protection.

Quick reference

Health, Safety and Fire Protection on Site and in Use

  • Loi du 17 juin 1994 (as amended) on safety and health at work - employer obligations; chantier coordination required when multiple contractors work on site (coordinateur sécurité-santé).

  • Loi du 8 juin 2004 on fire safety in residential buildings: smoke detectors in every dwelling; common areas protected; escape routes maintained.

  • Fire compartments: residential buildings - compartmentation between units (REI 30/60 depending on height); stairwells protected; max travel distance to exit ≈ 20 m (residential).

  • Reaction to fire: EN 13501-1 classification (A1 to F); floor coverings in escape routes ≥ Bfl-s1; wall linings ≥ B-s1,d0 in common areas.

  • Emergency lighting and signage: EN 1838; escape routes illuminated ≥ 1 lux; exit signs per ISO 7010.

  • Construction site: EN 13374 edge protection; scaffolding per EN 12811; excavation shoring required > 1.25 m depth; PPE per loi 1994.

  • Asbestos: loi du 6 février 2007 (as amended) - inventory required before renovation of buildings pre-2005; removal by certified firms.

  • Access for fire services: minimum 3 m wide access road, 4 m clear height, turning radius per communal règlement; dry riser in buildings > 8 m.

Quick reference

Accessibility and Inclusive Design

  • Loi du 7 janvier 2022 on accessibility (loi portant sur l'accessibilité des lieux ouverts au public) - replaces earlier provisions; applies to public buildings and public spaces.

  • Ramp: max slope 6% (5% preferred) for new buildings; length ≤ 10 m per flight; landing ≥ 1.5 m; handrails both sides at 0.90 m.

  • Door clear width ≥ 0.90 m (0.80 m minimum for interior doors in dwellings); threshold ≤ 2 cm; lever handles at 1.00-1.10 m.

  • Accessible WC: min. 1.50 m turning circle; grab bars; seat height 0.45-0.50 m; emergency call.

  • Corridors: min. 1.20 m clear width (1.50 m preferred); passing places every 10 m.

  • Lift: min. car 1.10 × 1.40 m; door width ≥ 0.90 m; controls at 0.90-1.20 m; tactile and acoustic signals.

  • Parking: accessible spaces min. 3.30 m wide (2.50 m + 0.80 m transfer); 1 per 50 spaces minimum; located near entrance.

  • Visual contrast: 30% luminance contrast for door frames, stair nosings; tactile guidance paths at public entrances.

Quick reference

Project Management, Contracts and Professional Responsibility

  • Architect's contract: loi du 28 décembre 1988 (as amended) on the profession of architect and engineer; architects must be registered with the Ordre des Architectes et des Ingénieurs-Conseils (OAI).

  • Mission types per OAI: esquisse, avant-projet, projet, dossier d'autorisation, appel d'offres, chantier, réception - defined in the contrat d'architecture.

  • Public procurement: loi du 8 avril 2018 on public contracts (transposes EU directives 2014/24/EU, 2014/25/EU); thresholds - €143,000 (works) / €221,000 (services) for central government; EU thresholds updated biennially.

  • Contract types: marché à forfait (lump sum), marché à bordereau (unit price), marché à régie (cost-plus); forfait limits variation claims to unforeseen circumstances.

  • Réception (handover): provisional acceptance (réception provisoire) starts the 1-year guarantee (garantie de parfait achèvement); 10-year decennial liability (responsabilité décennale) for structural and waterproofing defects.

  • Retenue de garantie: 5% of contract price retained until final acceptance; can be replaced by a bank guarantee.

  • Insurance: architects and contractors must hold professional indemnity (RC professionnelle) and decennial insurance (assurance décennale) for construction.

  • Delay penalties (pénalités de retard): typically 1/1000 of contract price per day, capped at 10%; force majeure suspends.

  • Site safety coordination: coordinateur sécurité-santé required from design phase (loi 1994); OAI code of ethics governs conflicts of interest and fee transparency.