Master Electrician · Get comfortable with the vocabulary.

Ampacity

The maximum current, in amperes, that a conductor or raceway can carry continuously under the conditions of use without exceeding its rated temperature limit. Adjusted for ambient temperature, number of conductors, and installation method.

Related: Voltage drop, Overcurrent protective device
Voltage drop

The reduction in voltage along a circuit caused by current flowing through conductor impedance. Excessive drop causes poor equipment performance and is limited by code recommendations for feeders and branch circuits.

Related: Ampacity, Feeder
Power factor

The ratio of real power in watts to apparent power in volt-amperes in an alternating-current circuit, ranging from zero to one and affecting current draw for a given load.

Related: Voltage drop, Demand factor
Outlet

A point on the wiring system at which current is taken to supply utilization equipment, such as a receptacle, luminaire, or appliance connection.

Related: Branch circuit
Raceway

An enclosed channel of metal or nonmetallic material designed expressly for holding wires, cables, or busbars, with additional functions permitted by code, such as metal conduit, EMT, or PVC.

Related: Plenum, Ampacity
Plenum

A compartment or chamber that forms part of the air-handling system, to which one or more ducts are connected and that is used as a supply or return air path. Wiring in it faces stricter rules.

Related: Raceway
Continuous load

A load in which the maximum current is expected to continue for three hours or more. Feeders, services, and overcurrent devices serving such loads must be sized at 125 percent of the load.

Related: Demand factor, Feeder
Demand factor

The ratio of the maximum demand on a system to the total connected load of that system. It permits feeders and services to be sized below the sum of all connected loads.

Related: Continuous load, Feeder
Feeder

All circuit conductors between the service equipment, source of a separately derived system, or other power supply source and the final branch-circuit overcurrent devices.

Related: Branch circuit, Overcurrent protective device, Demand factor
Branch circuit

The circuit conductors between the final overcurrent device protecting the circuit and the outlet or outlets it supplies. Multiwire and individual branch circuits are common variations.

Related: Feeder, Outlet, Overcurrent protective device
Overcurrent protective device

A fuse or circuit breaker that automatically opens a circuit when current exceeds a predetermined value, protecting conductors and equipment from overheating and damage caused by overloads or short circuits.

Related: Available fault current, Series-rated system, Tap conductor
Series-rated system

An arrangement in which a current-limiting device on the supply side is tested and listed in combination with downstream circuit breakers, allowing the downstream breakers to have interrupting ratings lower than the available fault current.

Related: Available fault current, Selective coordination
Selective coordination

The design and setting of overcurrent devices so that the device nearest a fault opens first, leaving other circuits energized. It is required for emergency systems and some health-care circuits.

Related: Series-rated system, Overcurrent protective device
Available fault current

The maximum current that can flow at a given point in a system during a short circuit, determined by the utility source strength, transformer impedance, and conductor impedance. Equipment ratings must equal or exceed it.

Related: Series-rated system, Overcurrent protective device, Transformer impedance
Tap conductor

A conductor, other than a service conductor, that has overcurrent protection ahead of its point of supply that exceeds the value permitted for similar conductors protecting the circuit.

Related: Overcurrent protective device, Feeder
Ground-fault circuit interrupter (GFCI)

A device that senses an imbalance between the current leaving and returning on circuit conductors and trips at a low threshold, typically 4 to 6 milliamperes, to protect people from electric shock.

Related: Equipment grounding conductor, Grounded conductor
Equipment grounding conductor

The conductive path installed to connect normally non-current-carrying metal parts of equipment together and to the system grounded conductor or grounding electrode, providing a low-impedance fault path.

Related: Bonding jumper, Grounding electrode system, Grounded conductor
Bonding jumper

A reliable conductor that ensures electrical continuity and the capacity to conduct safely any current likely to be imposed between two or more metal parts that are required to be bonded.

Related: Equipment grounding conductor, Grounding electrode system
Grounded conductor

A system conductor, usually the neutral, that is intentionally connected to earth through the grounding electrode system and carries return current under normal operation. It is white or gray in color.

Related: Equipment grounding conductor, Separately derived system
Grounding electrode system

A network of rods, pipes, plates, or concrete-encased electrodes that connects the electrical system to earth, establishing a reference and helping dissipate fault current.

Related: Equipment grounding conductor, Bonding jumper, Grounded conductor
Service point

The point of connection between the serving utility's facilities and the premises wiring, often at the service drop, service lateral, or meter, where code rules for services begin.

Related: Service-entrance conductor, Service equipment
Service-entrance conductor

The conductors between the service point and the service equipment, including any conductors supplying the service disconnecting means and the meter enclosure, sized for the calculated load and available fault current.

Related: Service point, Service equipment, Overcurrent protective device
Service equipment

The necessary equipment, usually consisting of circuit breakers or switches and fuses with associated accessories, connected to the load end of service conductors to control and cut off the supply.

Related: Service point, Panelboard, Disconnecting means
Panelboard

A single panel or group of panel units designed for assembly in a cabinet, containing buses and automatic overcurrent devices, for controlling and distributing power to branch circuits or feeders.

Related: Disconnecting means, Overcurrent protective device
Disconnecting means

A device or group of devices, or other means, by which the conductors of a circuit can be disconnected from their source of supply, providing a safe way to isolate equipment.

Related: Panelboard, Lockout/tagout, Service equipment
Surge protective device

A device that limits transient voltage surges on circuits by diverting or clamping excess energy, protecting equipment from lightning and switching surges. It may be at service, feeder, or branch level.

Related: Panelboard, Overcurrent protective device
Motor overload protection

A device or sensing means that protects the motor, motor-control apparatus, and branch-circuit conductors against overheating caused by running overloads or failure to start, typically set near the motor's nameplate current.

Related: Full-load current (FLC), Motor branch-circuit short-circuit and ground-fault protective device
Full-load current (FLC)

The current drawn by a motor when operating at rated horsepower, speed, and voltage with rated load. Code tables list values used for sizing branch circuits, feeders, and protective devices.

Related: Motor overload protection, Motor branch-circuit short-circuit and ground-fault protective device
Motor branch-circuit short-circuit and ground-fault protective device

A fuse, breaker, or motor-circuit protector selected to clear short circuits and ground faults without opening on normal motor starting current; it does not provide overload protection.

Related: Motor overload protection, Full-load current (FLC)
Transformer impedance

The percentage of rated voltage that must be applied to the primary to produce rated current in a short-circuited secondary. It strongly affects available fault current and voltage regulation.

Related: Available fault current, Separately derived system
Separately derived system

A premises wiring system whose power is derived from a source such as a transformer or generator and has no direct electrical connection, including a solidly connected grounded circuit conductor, to supply conductors originating in another system.

Related: Grounded conductor, Grounding electrode system
Hazardous (classified) location

An area where fire or explosion hazards may exist due to flammable gases, vapors, dusts, or fibers. Such locations are classified by class, division or zone, and group, governing equipment and wiring.

Related: Class I, Division 1 location
Class I, Division 1 location

A location where flammable gases or vapors are present in ignitable concentrations under normal operating conditions, or may exist frequently due to repair or maintenance, or where equipment failure could cause ignition.

Related: Hazardous (classified) location
Working clearance

The clear, unobstructed floor space required in front of electrical equipment, with depth based on voltage and conditions, and width and height dimensions to permit safe examination and servicing.

Related: Arc flash hazard, Disconnecting means
Arc flash hazard

A dangerous condition associated with the possible release of energy caused by an electric arc, producing intense heat, light, and pressure. It drives labeling, PPE selection, and safe work practices.

Related: Working clearance, Lockout/tagout
Lockout/tagout

A procedure for de-energizing equipment, applying locks and tags, and verifying absence of voltage so that servicing work cannot be re-energized accidentally. Required by safety standards and code.

Related: Arc flash hazard, Disconnecting means