MI Journeyman Electrician study materials
MI Journeyman Electrician study resources

MI Journeyman Electrician key terms

MI Journeyman Electrician · Get comfortable with the vocabulary.

Authority Having Jurisdiction (AHJ)

The organization or individual - often a local electrical inspector or building department - with legal authority to enforce the code, interpret its requirements, and approve materials and installations within a given area.

Related: Approved, Michigan Electrical Code
Approved

Acceptable to the authority having jurisdiction. An installation or material becomes approved when the inspector or governing body with legal authority has accepted it for the specific use intended.

Related: Authority Having Jurisdiction (AHJ), Listed
Listed

Equipment or material that appears in a published list from a recognized testing laboratory, showing it has been tested and found suitable for a specific purpose under stated conditions.

Related: Approved, Authority Having Jurisdiction (AHJ)
Qualified Person

Someone who has the skills and knowledge related to the construction and operation of electrical equipment and installations and has received safety training to recognize and avoid the hazards involved.

Related: Authority Having Jurisdiction (AHJ)
Michigan Electrical Code

The National Electrical Code as adopted into Michigan law through the state's electrical code rules, including Michigan amendments, and enforced statewide by the electrical division and by local inspectors.

Related: Authority Having Jurisdiction (AHJ), Approved
Special Permission

Written consent from the authority having jurisdiction allowing an installation the code does not cover by a specific rule. It is required wherever the code says work may be done only by special permission.

Related: Authority Having Jurisdiction (AHJ)
Service Point

The point where service conductors from the utility connect to the premises wiring - typically at the service drop, at the service lateral, or at the terminals of the service equipment.

Related: Service Drop, Service Lateral, Feeder
Service Drop

The overhead service conductors run by the utility from the last pole or transformer to the service point at the building, including splices and the attachment to the structure.

Related: Service Point, Service Lateral
Service Lateral

The underground service conductors run from the utility's distribution line or transformer to the service point, usually at the meter or service equipment on the premises.

Related: Service Point, Service Drop
Feeder

All circuit conductors between the service equipment, the source of a separately derived system, or another supply source and the final branch-circuit overcurrent device that supplies the load.

Related: Branch Circuit, Service Point
Branch Circuit

The circuit conductors between the final overcurrent device protecting the circuit and the outlets or utilization equipment that the circuit supplies.

Related: Feeder, Outlet
Multiwire Branch Circuit

A branch circuit made up of two or more ungrounded conductors with different voltages to the neutral and a shared grounded conductor, with the ungrounded conductors connected to different phases.

Related: Branch Circuit, Grounded Conductor
Continuous Load

A load expected to run at maximum current for three hours or more. Continuous loads are figured at 125 percent of their current when sizing conductors and overcurrent protection.

Related: Demand Factor, Overcurrent Protective Device
Demand Factor

The ratio of the maximum demand of a system, or part of it, to the total connected load. It lets you size conductors and services for realistic loads rather than every load running at once.

Related: Continuous Load, Feeder
Ampacity

The maximum current, in amperes, that a conductor can carry continuously under the conditions of use without exceeding its temperature rating, after adjustment for ambient temperature and conductor count.

Related: Raceway, Overcurrent Protective Device
Raceway

An enclosed channel of metal or nonmetallic material designed for holding wires, cables, or busbars, such as conduit, electrical tubing, or wireway.

Related: Conduit Fill, Electrical Metallic Tubing (EMT)
Conduit Fill

The percentage of a raceway's internal cross-sectional area taken up by conductors. Code limits the fill so conductors do not overheat and can be pulled in without damage.

Related: Raceway, Ampacity
Box Fill

The calculation of how many conductors, devices, and fittings an outlet or junction box may hold, based on each item's volume allowance compared with the box's cubic-inch capacity.

Related: Outlet, Conduit Fill
Electrical Metallic Tubing (EMT)

A thin-wall, unthreaded steel or aluminum raceway joined with couplings and fittings. It is common indoors and in concrete and must be secured and supported at code-specified intervals.

Related: Raceway, Minimum Bending Radius
Sheathed Cable

An assembly of insulated conductors wrapped in a flexible outer jacket, such as nonmetallic-sheathed cable, used mainly for residential branch circuits and secured and supported as the code requires.

Related: Raceway, Branch Circuit
Minimum Bending Radius

The smallest curve a raceway or cable may be bent without damaging the conductors or the raceway itself, set by code as a multiple of the raceway diameter or cable size.

Related: Raceway, Electrical Metallic Tubing (EMT)
Outlet

A point on the wiring system where current is taken to supply utilization equipment. It includes receptacles, luminaires, and the junction points that serve them.

Related: Receptacle, Utilization Equipment
Receptacle

A contact device installed at an outlet for the connection of an attachment plug. It supplies cord-and-plug-connected equipment and may be single, duplex, or of another configuration.

Related: Outlet, Utilization Equipment
Utilization Equipment

Equipment that uses electrical energy for electronic, electromechanical, chemical, heating, lighting, or similar purposes. Appliances, motors, and luminaires are everyday examples.

Related: Outlet, Luminaire
Disconnecting Means

A device or group of devices that can disconnect the conductors of a circuit from their source of supply, used to de-energize equipment safely for servicing or in an emergency.

Related: Working Space, Overcurrent Protective Device
Working Space

The clear, unobstructed area in front of electrical equipment that must be kept free so people can safely work on it. Depth and width depend on voltage and site conditions.

Related: Disconnecting Means
Luminaire

A complete lighting unit, including the lamp or lamps and the parts that hold them, position them, and connect them to the power supply.

Related: Utilization Equipment
Grounded Conductor

The circuit conductor that is intentionally connected to earth at the source - usually the neutral - and that carries current during normal operation.

Related: Equipment Grounding Conductor, Main Bonding Jumper
Equipment Grounding Conductor (EGC)

The conductive path run with circuit conductors that connects metal enclosures and equipment to the grounding system, giving fault current a low-impedance path back to the source.

Related: Grounded Conductor, Grounding Electrode
Grounding Electrode

A conductive object in direct contact with the earth, such as a ground rod, metal water pipe, or concrete-encased electrode, that ties the grounding system to the earth.

Related: Equipment Grounding Conductor, Main Bonding Jumper
Main Bonding Jumper

The connection between the grounded circuit conductor and the equipment grounding conductor, or the supply-side bonding jumper, at the service or at a separately derived system.

Related: Grounded Conductor, Grounding Electrode
Overcurrent Protective Device

A device such as a fuse or circuit breaker that opens a circuit when current exceeds a set value, protecting conductors and equipment from overheating, short circuits, and ground faults.

Related: Interrupting Rating, Ampacity
Ground-Fault Circuit Interrupter (GFCI)

A device that senses a small current difference between the ungrounded and grounded conductors and quickly opens the circuit to prevent shock, required in bathrooms, kitchens, outdoors, and other wet or damp areas.

Related: Arc-Fault Circuit Interrupter (AFCI), Receptacle
Arc-Fault Circuit Interrupter (AFCI)

A device that detects the current and voltage patterns of arcing faults and opens the circuit, protecting branch circuits from fires started by damaged or loose wiring.

Related: Ground-Fault Circuit Interrupter (GFCI), Branch Circuit
Interrupting Rating

The highest current a fuse or circuit breaker is designed to safely interrupt at its rated voltage. It must equal or exceed the available fault current where the device is installed.

Related: Overcurrent Protective Device
Classified Location

An area where fire or explosion hazards may exist because of flammable gases, vapors, dusts, or fibers. Equipment installed there must be specially listed and marked for the hazard.

Related: Listed, Approved