MI Journeyman Electrician study plan
MI Journeyman Electrician · Give each week a clear focus.
8 weeks · About 7 hours per week
General Electrical Knowledge and Code Administration & Services, Feeders, and Branch Circuits
Map the NEC structure: locate any cited Article, Part, or table using the table of contents and index in under 60 seconds
Distinguish mandatory (shall), permissive (permitted), and informational note language, and cite three examples of each
Identify Michigan licensing and Code-adoption administrative rules that govern journeyman scope of work
Compute a single-family dwelling service load with the Article 220 Part III standard method, showing every step
Your checkpoint
A one-page personal index of the 25 most-tested Articles plus 10 completed standard-method dwelling load calculations, each step tagged with the governing section number
Services, Feeders, and Branch Circuits
Size service-entrance conductors and service OCPDs using Article 230 and the dwelling service table allowance
Calculate feeder and neutral demand loads for a multifamily or commercial occupancy with the Article 220 optional method
Apply dwelling receptacle-spacing and small-appliance/laundry branch-circuit rules to a floor plan
Apply GFCI and AFCI protection requirements to specific branch-circuit locations
Your checkpoint
Fifteen service and feeder sizing problems solved end-to-end with cited sections, plus a room-by-room receptacle and GFCI placement plan for a two-bedroom dwelling
Wiring Methods, Materials, and Raceways
Determine conductor ampacity from the wet/dry location table and apply ambient-temperature and conduit-fill adjustment factors
Perform box-fill calculations for outlet, device, and junction boxes including conductor, device, and equipment-grounding allowances
Match occupancy and location conditions to an acceptable wiring method among NM, MC, AC, PVC, and EMT
Verify securing, supporting, and protection-from-physical-damage requirements for three wiring methods
Your checkpoint
Twenty mixed ampacity and box-fill problems worked with cited sections, scored at 85 percent or better on a self-graded answer key
Wiring Methods, Materials, and Raceways & Equipment, Devices, and Utilization Equipment
Use the Chapter 9 conduit-fill and bending tables to select raceway size and verify raceway fill for mixed conductor sizes
Size motor branch-circuit conductors, short-circuit protection, and overload protection for a single-motor circuit
Connect disconnecting-means and controller requirements to a motor installation layout
Interpret equipment nameplate data to select branch-circuit conductors and overcurrent devices for HVAC equipment
Your checkpoint
A timed 25-question quiz on Chapter 9 tables and Article 430/440 calculations, completed in 45 minutes and scored at 80 percent or above
Grounding, Bonding, Overcurrent Protection, and Special Occupancies
Build a grounding electrode system from a site description and size grounding electrode conductors and bonding jumpers
Size equipment-grounding conductors for multiple circuits using the equipment-grounding conductor table and its adjustment rules
Apply tap-conductor and next-size-up rules to select and verify overcurrent device ratings
Differentiate grounding, bonding, and the grounded conductor at the service and at separately derived systems
Your checkpoint
A one-page grounding and bonding decision flowchart plus 15 grounding-electrode and equipment-grounding conductor sizing problems with cited sections
Grounding, Bonding, Overcurrent Protection, and Special Occupancies & Equipment, Devices, and Utilization Equipment
Compare GFCI and AFCI requirements across dwelling, healthcare, aquatic, and assembly occupancies
Apply special-occupancy Articles to pool, patient-care, and emergency/standby system installations
Select wiring methods, boxes, and devices permitted in hazardous (classified) locations by class and division
Evaluate multiwire branch circuits, handle ties, and common-trip requirements for shared-neutral circuits
Your checkpoint
A comparison matrix of protection-device and wiring requirements for six special occupancies, plus a 20-question quiz scored at 80 percent or above
General Electrical Knowledge and Code Administration & Services, Feeders, and Branch Circuits & Wiring Methods, Materials, and Raceways & Equipment, Devices, and Utilization Equipment & Grounding, Bonding, Overcurrent Protection, and Special Occupancies
Complete 150 mixed practice questions under timed conditions, rotating across all five domains
Log every missed question by domain, root cause, and correct cited section
Re-drill the two lowest-scoring domains until accuracy exceeds 80 percent
Reduce average time per calculation question to under 90 seconds
Your checkpoint
An error log of at least 50 missed items categorized by domain and root cause, with a written remediation plan naming the sections to re-study
Services, Feeders, and Branch Circuits & Wiring Methods, Materials, and Raceways & Grounding, Bonding, Overcurrent Protection, and Special Occupancies
Complete two full-length 80-question simulated exams under strict timing with only the Code book as reference
Memorize the table locations and standard values most frequently tested: ampacity, box fill, conductor fill, and grounding conductor sizing
Re-verify weak areas flagged in the week 7 error log until repeat accuracy is 90 percent or better
Assemble a final one-page reference sheet of section numbers and exceptions to review the morning of the exam
Your checkpoint
Two completed full-length exams scored at 80 percent or better, plus a final one-page last-look sheet of high-frequency sections and tables
Milestones
Week 2: Locate 20 randomly drawn Code sections in under 60 seconds each and score 80 percent or better on a 15-question service and feeder calculation check
Week 4: Score 80 percent or better on a closed-book 30-question mixed quiz covering Domains 2 and 3, using the Code only for tables
Week 6: Score 80 percent or better on a 25-question grounding, bonding, overcurrent, and special-occupancy quiz, with every answer citing a section number
Week 8: Score 80 percent or better on two timed full-length simulated exams and reduce the week 7 error log to zero repeat mistakes