MI Elevator Mechanic study materials
MI Elevator Mechanic study resources

MI Elevator Mechanic cheat sheet

MI Elevator Mechanic · Keep the key ideas within reach.

Quick reference

Elevator and Escalator Code Requirements (ASME A17.1/CSA B44)

  • A17.1/B44 is the design, construction, installation, and alteration code; A17.2 covers inspection, A17.3 covers existing installations, and A17.5 covers electrical equipment.

  • Minimum rated load for passenger elevators is based on car floor area: 50 lb per square foot of net floor area is the lower bound used with the code's area-load table.

  • Clear inside car height must be at least 7 ft (2.13 m); car doors must be at least 6 ft 8 in (2.03 m) high and provide an unobstructed clear opening.

  • Required car lighting: at least 2 ft-candles (21.5 lux) at the car floor with doors closed, and emergency lighting of at least 5 ft-candles for 4 hours at the car threshold.

  • Escalator: maximum rise per unit is 60 ft (18.3 m); nominal speed may not exceed 125 ft/min (0.63 m/s) where the rise exceeds 20 ft, and 100 ft/min where rise is 20 ft or less.

  • Escalator rated load is computed as 2 persons per 16 in (400 mm) of nominal width per step band segment; the code assumes 50% occupancy for capacity-based calculations.

  • Escalator clearance: minimum 7 ft (2.13 m) vertical clearance above the step band to any obstruction, and 2 ft 4 in (711 mm) between handrail centerlines minimum.

  • Machine-room and control-space access doors must be self-closing and self-locking, open outward, and be at least 30 in (762 mm) wide by 6 ft 8 in (2.03 m) high.

Quick reference

Electrical Theory, Circuits, and Motor Controls

  • Ohm's law: E = I x R; power in a DC or resistive circuit: P = E x I = I^2 R = E^2 / R.

  • Three-phase power: P (watts) = 1.732 x E_line x I_line x power factor; synchronous speed N = 120f / P where P is pole count.

  • Motor slip: percent slip = (N_sync - N_measured) / N_sync x 100; typical NEMA Design B induction motors run 2-4% slip at rated load.

  • Across-the-line starting draws roughly 6x nameplate full-load current; wye-delta and reduced-voltage starters lower inrush at the cost of torque.

  • A dynamic braking resistor converts motor kinetic energy to heat during deceleration; the resistor's duty rating, not its ohmic value alone, sets its thermal limit.

  • NEMA contactor sizing is by horsepower rating and utilization category (AC-3 for squirrel-cage motor starting), not just by amp rating.

  • A ground-fault circuit must trip at 5 mA +/- 1 mA for personnel protection; equipment GFCI in elevator circuits is typically set at 30 mA or higher per code.

  • Variable-frequency drives require shielded motor cable with the shield grounded at the drive end; long cable runs cause reflected-wave overvoltage at the motor terminals.

Quick reference

Mechanical Components, Hoisting, and Roping Systems

  • Traction ratio = total load on the sheave divided by the lesser rope tension; 1:1 roping has a ratio of 1, 2:1 has 2, and higher ratios reduce rope load but double rope travel.

  • Suspension rope safety factor: at least 12 for traction elevators with rated speed above 50 ft/min, and at least 16 for drum-type machines per A17.1.

  • Minimum number of suspension ropes is 3 for traction elevators; each rope must be independently terminated and equalized.

  • Rope construction for elevators is typically 6x19 or 8x19 seale independent wire rope core (IWRC); fiber-core ropes are not permitted for traction suspension.

  • Sheave-to-rope diameter ratio must be at least 40:1 for traction machines; smaller ratios accelerate fatigue and require more frequent inspection.

  • Rope wear rejection: replace when diameter reduction exceeds the code limit (roughly 3% below nominal for 6-8 strand ropes) or when broken wires in one lay exceed the A17.1 table.

  • Counterweight equals car weight plus approximately 40-50% of rated load, balancing the system so the machine sees near-equal tension up and down.

  • Guide rail alignment tolerance is typically 1/8 in (3 mm) over 5 ft; misalignment causes roller or gib wear and car sway.

Quick reference

Safety Devices, Governors, and Braking Systems

  • Governor tripping speed is set between 115% and 140% of rated speed for car governors; the tripping speed must not exceed the value in the A17.1 table for the rated speed.

  • The safety (car or counterweight) must stop the car within the code's deceleration limit; the governor tripping speed and safety setting combine to produce this.

  • Instantaneous safeties are permitted only below the code's speed threshold (typically 200 ft/min for cars); above that, type A or type B progressive safeties are required.

  • The governor rope must be at least 1/4 in (6.4 mm) diameter and must be tensioned so the governor operates before the car reaches the pit buffers.

  • Buffers: oil buffers are required for rated speeds above 200 ft/min; spring buffers are permitted below that. Buffer stroke must match the code table for rated speed.

  • Brake torque must hold 125% of rated load; the brake is set by spring and released by magnet or hydraulic pressure, so loss of power applies the brake.

  • The brake must be a friction type with a self-engaging design; a brake that depends on electrical or hydraulic power to set is not permitted.

  • Final limit switches must be independent of the normal limit switches and must open the power circuit before the car or counterweight reaches the buffer.

Quick reference

Hydraulic Elevator Systems

  • Hydraulic elevators are limited to a maximum travel of about 60 ft (18.3 m) for in-ground cylinders and 50 ft (15.2 m) for holeless telescoping cylinders.

  • Rated speed of a hydraulic elevator is set by pump displacement and plunger area: v = Q / A, so doubling plunger area halves speed at the same flow.

  • The relief valve must be set to open at no more than 150% of the full-load pressure and must be tested with the car at rest and loaded.

  • The check valve holds the car when the pump stops; the lowering valve controls descent. Both must be tested for leakage and response time.

  • The pressure switch and rupture valve protect against line failure; the rupture valve must close when flow exceeds the design limit, stopping the car.

  • Hydraulic fluid temperature affects viscosity and speed; typical operating range is 60-140 F, and low temperature raises pressure and slows descent.

  • The cylinder must have a means to detect and remove air; trapped air causes spongy ride and can allow the car to drop when the pump stops.

  • The pit must have a drain or sump and the cylinder must be protected against corrosion; a failed cylinder casing leaks oil into the pit and is a code violation.

Quick reference

Maintenance, Inspection, and Testing Procedures

  • Periodic inspection intervals are set by the authority having jurisdiction; A17.2 inspection procedures cover car, machine room, pit, and hoistway, in that order.

  • Annual tests include: safety device test with rated load, governor tripping speed, buffer test, brake test, and relief valve test on hydraulic units.

  • Five-year tests include: safety device test at 125% of rated load and a full-load test of the machine and brake.

  • The governor tripping speed is measured with a tachometer at the governor or by the rope speed; record the measured speed and compare to the A17.1 table.

  • The safety test is performed by tripping the governor and observing the car stop; measure the stopping distance and check for even engagement of both safety blocks.

  • Escalator inspection: check step-to-skirt clearance (not more than 3/16 in per side), comb teeth engagement, handrail speed, and the stop switch operation.

  • Maintenance records must be kept for each unit and made available to the inspector; missing records are a common cause of failed inspections.

  • Tag-out/lock-out is required before any work in the hoistway or machine room; the mainline disconnect must be locked open and the key controlled by the mechanic.

Quick reference

Michigan Elevator Safety Rules and Licensing Regulations

  • Michigan elevator work is regulated by the Elevator Safety Board within the Department of Licensing and Regulatory Affairs (LARA); the board adopts ASME A17.1 and A17.3 by reference.

  • Elevator mechanic and elevator contractor licenses are issued by LARA; work must be performed by or under the direct supervision of a licensed elevator mechanic.

  • Continuing education is required to renew a mechanic license; the board sets the hours and approved course categories.

  • Permits are required before installing or altering an elevator; the contractor submits plans and the state inspects before the unit is placed in service.

  • Periodic inspections in Michigan are performed at intervals set by rule; the owner is responsible for arranging inspection and paying fees.

  • A certificate of operation must be posted in the elevator car or machine room and renewed annually after inspection.

  • Unlicensed elevator work is a violation subject to civil penalties and may result in the contractor's license suspension or revocation.

  • Appeals of board or department decisions go through the Michigan Administrative Hearing System; a request must be filed within the time stated in the department's notice.

Quick reference

Jobsite Safety, Rigging, and OSHA Practices

  • OSHA fall protection for general industry is triggered at 4 ft; in construction, at 6 ft. Elevator hoistway work uses fall protection at the pit and at the car top.

  • A full-body harness with lanyard and a rated anchor point is required for hoistway work; the anchor must support 5,000 lb per worker or be designed by a qualified person.

  • Rigging: the working load limit of a sling is its vertical rating reduced by the sling angle; at 30 degrees from horizontal, capacity drops to 50% of vertical.

  • Never exceed the rated capacity of a shackle, hook, or chain; hooks must have a functioning safety latch and be inspected before each lift.

  • Hoisting a car or counterweight requires a rated beam or hoist point and a load test before personnel work under it; never use the elevator machine as a rigging point.

  • Lockout/tagout (29 CFR 1910.147) applies to elevator maintenance: isolate all energy sources, verify zero energy, and apply personal locks.

  • Confined-space entry rules apply to pits with limited access; test for oxygen, combustible gas, and hydrogen sulfide before entry where applicable.

  • Housekeeping: keep the pit and machine room clear of oil, tools, and debris; oil on the pit floor is a slip hazard and a fire hazard.

Quick reference

Elevator and Escalator Code Requirements (ASME A17.1/CSA B44)

  • A17.1/B44 is the design, construction, installation, and alteration code; A17.2 covers inspection, A17.3 covers existing installations, and A17.5 covers electrical equipment.

  • Minimum rated load for passenger elevators is based on car floor area: 50 lb per square foot of net floor area is the lower bound used with the code's area-load table.

  • Clear inside car height must be at least 7 ft (2.13 m); car doors must be at least 6 ft 8 in (2.03 m) high and provide an unobstructed clear opening.

  • Required car lighting: at least 2 ft-candles (21.5 lux) at the car floor with doors closed, and emergency lighting of at least 5 ft-candles for 4 hours at the car threshold.

  • Escalator: maximum rise per unit is 60 ft (18.3 m); nominal speed may not exceed 125 ft/min (0.63 m/s) where the rise exceeds 20 ft, and 100 ft/min where rise is 20 ft or less.

  • Escalator rated load is computed as 2 persons per 16 in (400 mm) of nominal width per step band segment; the code assumes 50% occupancy for capacity-based calculations.

  • Escalator clearance: minimum 7 ft (2.13 m) vertical clearance above the step band to any obstruction, and 2 ft 4 in (711 mm) between handrail centerlines minimum.

  • Machine-room and control-space access doors must be self-closing and self-locking, open outward, and be at least 30 in (762 mm) wide by 6 ft 8 in (2.03 m) high.

Quick reference

Electrical Theory, Circuits, and Motor Controls

  • Ohm's law: E = I x R; power in a DC or resistive circuit: P = E x I = I^2 R = E^2 / R.

  • Three-phase power: P (watts) = 1.732 x E_line x I_line x power factor; synchronous speed N = 120f / P where P is pole count.

  • Motor slip: percent slip = (N_sync - N_measured) / N_sync x 100; typical NEMA Design B induction motors run 2-4% slip at rated load.

  • Across-the-line starting draws roughly 6x nameplate full-load current; wye-delta and reduced-voltage starters lower inrush at the cost of torque.

  • A dynamic braking resistor converts motor kinetic energy to heat during deceleration; the resistor's duty rating, not its ohmic value alone, sets its thermal limit.

  • NEMA contactor sizing is by horsepower rating and utilization category (AC-3 for squirrel-cage motor starting), not just by amp rating.

  • A ground-fault circuit must trip at 5 mA +/- 1 mA for personnel protection; equipment GFCI in elevator circuits is typically set at 30 mA or higher per code.

  • Variable-frequency drives require shielded motor cable with the shield grounded at the drive end; long cable runs cause reflected-wave overvoltage at the motor terminals.

Quick reference

Mechanical Components, Hoisting, and Roping Systems

  • Traction ratio = total load on the sheave divided by the lesser rope tension; 1:1 roping has a ratio of 1, 2:1 has 2, and higher ratios reduce rope load but double rope travel.

  • Suspension rope safety factor: at least 12 for traction elevators with rated speed above 50 ft/min, and at least 16 for drum-type machines per A17.1.

  • Minimum number of suspension ropes is 3 for traction elevators; each rope must be independently terminated and equalized.

  • Rope construction for elevators is typically 6x19 or 8x19 seale independent wire rope core (IWRC); fiber-core ropes are not permitted for traction suspension.

  • Sheave-to-rope diameter ratio must be at least 40:1 for traction machines; smaller ratios accelerate fatigue and require more frequent inspection.

  • Rope wear rejection: replace when diameter reduction exceeds the code limit (roughly 3% below nominal for 6-8 strand ropes) or when broken wires in one lay exceed the A17.1 table.

  • Counterweight equals car weight plus approximately 40-50% of rated load, balancing the system so the machine sees near-equal tension up and down.

  • Guide rail alignment tolerance is typically 1/8 in (3 mm) over 5 ft; misalignment causes roller or gib wear and car sway.

Quick reference

Safety Devices, Governors, and Braking Systems

  • Governor tripping speed is set between 115% and 140% of rated speed for car governors; the tripping speed must not exceed the value in the A17.1 table for the rated speed.

  • The safety (car or counterweight) must stop the car within the code's deceleration limit; the governor tripping speed and safety setting combine to produce this.

  • Instantaneous safeties are permitted only below the code's speed threshold (typically 200 ft/min for cars); above that, type A or type B progressive safeties are required.

  • The governor rope must be at least 1/4 in (6.4 mm) diameter and must be tensioned so the governor operates before the car reaches the pit buffers.

  • Buffers: oil buffers are required for rated speeds above 200 ft/min; spring buffers are permitted below that. Buffer stroke must match the code table for rated speed.

  • Brake torque must hold 125% of rated load; the brake is set by spring and released by magnet or hydraulic pressure, so loss of power applies the brake.

  • The brake must be a friction type with a self-engaging design; a brake that depends on electrical or hydraulic power to set is not permitted.

  • Final limit switches must be independent of the normal limit switches and must open the power circuit before the car or counterweight reaches the buffer.

Quick reference

Hydraulic Elevator Systems

  • Hydraulic elevators are limited to a maximum travel of about 60 ft (18.3 m) for in-ground cylinders and 50 ft (15.2 m) for holeless telescoping cylinders.

  • Rated speed of a hydraulic elevator is set by pump displacement and plunger area: v = Q / A, so doubling plunger area halves speed at the same flow.

  • The relief valve must be set to open at no more than 150% of the full-load pressure and must be tested with the car at rest and loaded.

  • The check valve holds the car when the pump stops; the lowering valve controls descent. Both must be tested for leakage and response time.

  • The pressure switch and rupture valve protect against line failure; the rupture valve must close when flow exceeds the design limit, stopping the car.

  • Hydraulic fluid temperature affects viscosity and speed; typical operating range is 60-140 F, and low temperature raises pressure and slows descent.

  • The cylinder must have a means to detect and remove air; trapped air causes spongy ride and can allow the car to drop when the pump stops.

  • The pit must have a drain or sump and the cylinder must be protected against corrosion; a failed cylinder casing leaks oil into the pit and is a code violation.

Quick reference

Maintenance, Inspection, and Testing Procedures

  • Periodic inspection intervals are set by the authority having jurisdiction; A17.2 inspection procedures cover car, machine room, pit, and hoistway, in that order.

  • Annual tests include: safety device test with rated load, governor tripping speed, buffer test, brake test, and relief valve test on hydraulic units.

  • Five-year tests include: safety device test at 125% of rated load and a full-load test of the machine and brake.

  • The governor tripping speed is measured with a tachometer at the governor or by the rope speed; record the measured speed and compare to the A17.1 table.

  • The safety test is performed by tripping the governor and observing the car stop; measure the stopping distance and check for even engagement of both safety blocks.

  • Escalator inspection: check step-to-skirt clearance (not more than 3/16 in per side), comb teeth engagement, handrail speed, and the stop switch operation.

  • Maintenance records must be kept for each unit and made available to the inspector; missing records are a common cause of failed inspections.

  • Tag-out/lock-out is required before any work in the hoistway or machine room; the mainline disconnect must be locked open and the key controlled by the mechanic.

Quick reference

Michigan Elevator Safety Rules and Licensing Regulations

  • Michigan elevator work is regulated by the Elevator Safety Board within the Department of Licensing and Regulatory Affairs (LARA); the board adopts ASME A17.1 and A17.3 by reference.

  • Elevator mechanic and elevator contractor licenses are issued by LARA; work must be performed by or under the direct supervision of a licensed elevator mechanic.

  • Continuing education is required to renew a mechanic license; the board sets the hours and approved course categories.

  • Permits are required before installing or altering an elevator; the contractor submits plans and the state inspects before the unit is placed in service.

  • Periodic inspections in Michigan are performed at intervals set by rule; the owner is responsible for arranging inspection and paying fees.

  • A certificate of operation must be posted in the elevator car or machine room and renewed annually after inspection.

  • Unlicensed elevator work is a violation subject to civil penalties and may result in the contractor's license suspension or revocation.

  • Appeals of board or department decisions go through the Michigan Administrative Hearing System; a request must be filed within the time stated in the department's notice.

Quick reference

Jobsite Safety, Rigging, and OSHA Practices

  • OSHA fall protection for general industry is triggered at 4 ft; in construction, at 6 ft. Elevator hoistway work uses fall protection at the pit and at the car top.

  • A full-body harness with lanyard and a rated anchor point is required for hoistway work; the anchor must support 5,000 lb per worker or be designed by a qualified person.

  • Rigging: the working load limit of a sling is its vertical rating reduced by the sling angle; at 30 degrees from horizontal, capacity drops to 50% of vertical.

  • Never exceed the rated capacity of a shackle, hook, or chain; hooks must have a functioning safety latch and be inspected before each lift.

  • Hoisting a car or counterweight requires a rated beam or hoist point and a load test before personnel work under it; never use the elevator machine as a rigging point.

  • Lockout/tagout (29 CFR 1910.147) applies to elevator maintenance: isolate all energy sources, verify zero energy, and apply personal locks.

  • Confined-space entry rules apply to pits with limited access; test for oxygen, combustible gas, and hydrogen sulfide before entry where applicable.

  • Housekeeping: keep the pit and machine room clear of oil, tools, and debris; oil on the pit floor is a slip hazard and a fire hazard.

Quick reference

Elevator and Escalator Code Requirements (ASME A17.1/CSA B44)

  • A17.1/B44 is the design, construction, installation, and alteration code; A17.2 covers inspection, A17.3 covers existing installations, and A17.5 covers electrical equipment.

  • Minimum rated load for passenger elevators is based on car floor area: 50 lb per square foot of net floor area is the lower bound used with the code's area-load table.

  • Clear inside car height must be at least 7 ft (2.13 m); car doors must be at least 6 ft 8 in (2.03 m) high and provide an unobstructed clear opening.

  • Required car lighting: at least 2 ft-candles (21.5 lux) at the car floor with doors closed, and emergency lighting of at least 5 ft-candles for 4 hours at the car threshold.

  • Escalator: maximum rise per unit is 60 ft (18.3 m); nominal speed may not exceed 125 ft/min (0.63 m/s) where the rise exceeds 20 ft, and 100 ft/min where rise is 20 ft or less.

  • Escalator rated load is computed as 2 persons per 16 in (400 mm) of nominal width per step band segment; the code assumes 50% occupancy for capacity-based calculations.

  • Escalator clearance: minimum 7 ft (2.13 m) vertical clearance above the step band to any obstruction, and 2 ft 4 in (711 mm) between handrail centerlines minimum.

  • Machine-room and control-space access doors must be self-closing and self-locking, open outward, and be at least 30 in (762 mm) wide by 6 ft 8 in (2.03 m) high.

Quick reference

Electrical Theory, Circuits, and Motor Controls

  • Ohm's law: E = I x R; power in a DC or resistive circuit: P = E x I = I^2 R = E^2 / R.

  • Three-phase power: P (watts) = 1.732 x E_line x I_line x power factor; synchronous speed N = 120f / P where P is pole count.

  • Motor slip: percent slip = (N_sync - N_measured) / N_sync x 100; typical NEMA Design B induction motors run 2-4% slip at rated load.

  • Across-the-line starting draws roughly 6x nameplate full-load current; wye-delta and reduced-voltage starters lower inrush at the cost of torque.

  • A dynamic braking resistor converts motor kinetic energy to heat during deceleration; the resistor's duty rating, not its ohmic value alone, sets its thermal limit.

  • NEMA contactor sizing is by horsepower rating and utilization category (AC-3 for squirrel-cage motor starting), not just by amp rating.

  • A ground-fault circuit must trip at 5 mA +/- 1 mA for personnel protection; equipment GFCI in elevator circuits is typically set at 30 mA or higher per code.

  • Variable-frequency drives require shielded motor cable with the shield grounded at the drive end; long cable runs cause reflected-wave overvoltage at the motor terminals.

Quick reference

Mechanical Components, Hoisting, and Roping Systems

  • Traction ratio = total load on the sheave divided by the lesser rope tension; 1:1 roping has a ratio of 1, 2:1 has 2, and higher ratios reduce rope load but double rope travel.

  • Suspension rope safety factor: at least 12 for traction elevators with rated speed above 50 ft/min, and at least 16 for drum-type machines per A17.1.

  • Minimum number of suspension ropes is 3 for traction elevators; each rope must be independently terminated and equalized.

  • Rope construction for elevators is typically 6x19 or 8x19 seale independent wire rope core (IWRC); fiber-core ropes are not permitted for traction suspension.

  • Sheave-to-rope diameter ratio must be at least 40:1 for traction machines; smaller ratios accelerate fatigue and require more frequent inspection.

  • Rope wear rejection: replace when diameter reduction exceeds the code limit (roughly 3% below nominal for 6-8 strand ropes) or when broken wires in one lay exceed the A17.1 table.

  • Counterweight equals car weight plus approximately 40-50% of rated load, balancing the system so the machine sees near-equal tension up and down.

  • Guide rail alignment tolerance is typically 1/8 in (3 mm) over 5 ft; misalignment causes roller or gib wear and car sway.

Quick reference

Safety Devices, Governors, and Braking Systems

  • Governor tripping speed is set between 115% and 140% of rated speed for car governors; the tripping speed must not exceed the value in the A17.1 table for the rated speed.

  • The safety (car or counterweight) must stop the car within the code's deceleration limit; the governor tripping speed and safety setting combine to produce this.

  • Instantaneous safeties are permitted only below the code's speed threshold (typically 200 ft/min for cars); above that, type A or type B progressive safeties are required.

  • The governor rope must be at least 1/4 in (6.4 mm) diameter and must be tensioned so the governor operates before the car reaches the pit buffers.

  • Buffers: oil buffers are required for rated speeds above 200 ft/min; spring buffers are permitted below that. Buffer stroke must match the code table for rated speed.

  • Brake torque must hold 125% of rated load; the brake is set by spring and released by magnet or hydraulic pressure, so loss of power applies the brake.

  • The brake must be a friction type with a self-engaging design; a brake that depends on electrical or hydraulic power to set is not permitted.

  • Final limit switches must be independent of the normal limit switches and must open the power circuit before the car or counterweight reaches the buffer.

Quick reference

Hydraulic Elevator Systems

  • Hydraulic elevators are limited to a maximum travel of about 60 ft (18.3 m) for in-ground cylinders and 50 ft (15.2 m) for holeless telescoping cylinders.

  • Rated speed of a hydraulic elevator is set by pump displacement and plunger area: v = Q / A, so doubling plunger area halves speed at the same flow.

  • The relief valve must be set to open at no more than 150% of the full-load pressure and must be tested with the car at rest and loaded.

  • The check valve holds the car when the pump stops; the lowering valve controls descent. Both must be tested for leakage and response time.

  • The pressure switch and rupture valve protect against line failure; the rupture valve must close when flow exceeds the design limit, stopping the car.

  • Hydraulic fluid temperature affects viscosity and speed; typical operating range is 60-140 F, and low temperature raises pressure and slows descent.

  • The cylinder must have a means to detect and remove air; trapped air causes spongy ride and can allow the car to drop when the pump stops.

  • The pit must have a drain or sump and the cylinder must be protected against corrosion; a failed cylinder casing leaks oil into the pit and is a code violation.

Quick reference

Maintenance, Inspection, and Testing Procedures

  • Periodic inspection intervals are set by the authority having jurisdiction; A17.2 inspection procedures cover car, machine room, pit, and hoistway, in that order.

  • Annual tests include: safety device test with rated load, governor tripping speed, buffer test, brake test, and relief valve test on hydraulic units.

  • Five-year tests include: safety device test at 125% of rated load and a full-load test of the machine and brake.

  • The governor tripping speed is measured with a tachometer at the governor or by the rope speed; record the measured speed and compare to the A17.1 table.

  • The safety test is performed by tripping the governor and observing the car stop; measure the stopping distance and check for even engagement of both safety blocks.

  • Escalator inspection: check step-to-skirt clearance (not more than 3/16 in per side), comb teeth engagement, handrail speed, and the stop switch operation.

  • Maintenance records must be kept for each unit and made available to the inspector; missing records are a common cause of failed inspections.

  • Tag-out/lock-out is required before any work in the hoistway or machine room; the mainline disconnect must be locked open and the key controlled by the mechanic.

Quick reference

Michigan Elevator Safety Rules and Licensing Regulations

  • Michigan elevator work is regulated by the Elevator Safety Board within the Department of Licensing and Regulatory Affairs (LARA); the board adopts ASME A17.1 and A17.3 by reference.

  • Elevator mechanic and elevator contractor licenses are issued by LARA; work must be performed by or under the direct supervision of a licensed elevator mechanic.

  • Continuing education is required to renew a mechanic license; the board sets the hours and approved course categories.

  • Permits are required before installing or altering an elevator; the contractor submits plans and the state inspects before the unit is placed in service.

  • Periodic inspections in Michigan are performed at intervals set by rule; the owner is responsible for arranging inspection and paying fees.

  • A certificate of operation must be posted in the elevator car or machine room and renewed annually after inspection.

  • Unlicensed elevator work is a violation subject to civil penalties and may result in the contractor's license suspension or revocation.

  • Appeals of board or department decisions go through the Michigan Administrative Hearing System; a request must be filed within the time stated in the department's notice.

Quick reference

Jobsite Safety, Rigging, and OSHA Practices

  • OSHA fall protection for general industry is triggered at 4 ft; in construction, at 6 ft. Elevator hoistway work uses fall protection at the pit and at the car top.

  • A full-body harness with lanyard and a rated anchor point is required for hoistway work; the anchor must support 5,000 lb per worker or be designed by a qualified person.

  • Rigging: the working load limit of a sling is its vertical rating reduced by the sling angle; at 30 degrees from horizontal, capacity drops to 50% of vertical.

  • Never exceed the rated capacity of a shackle, hook, or chain; hooks must have a functioning safety latch and be inspected before each lift.

  • Hoisting a car or counterweight requires a rated beam or hoist point and a load test before personnel work under it; never use the elevator machine as a rigging point.

  • Lockout/tagout (29 CFR 1910.147) applies to elevator maintenance: isolate all energy sources, verify zero energy, and apply personal locks.

  • Confined-space entry rules apply to pits with limited access; test for oxygen, combustible gas, and hydrogen sulfide before entry where applicable.

  • Housekeeping: keep the pit and machine room clear of oil, tools, and debris; oil on the pit floor is a slip hazard and a fire hazard.

Quick reference

Elevator and Escalator Code Requirements (ASME A17.1/CSA B44)

  • A17.1/B44 is the design, construction, installation, and alteration code; A17.2 covers inspection, A17.3 covers existing installations, and A17.5 covers electrical equipment.

  • Minimum rated load for passenger elevators is based on car floor area: 50 lb per square foot of net floor area is the lower bound used with the code's area-load table.

  • Clear inside car height must be at least 7 ft (2.13 m); car doors must be at least 6 ft 8 in (2.03 m) high and provide an unobstructed clear opening.

  • Required car lighting: at least 2 ft-candles (21.5 lux) at the car floor with doors closed, and emergency lighting of at least 5 ft-candles for 4 hours at the car threshold.

  • Escalator: maximum rise per unit is 60 ft (18.3 m); nominal speed may not exceed 125 ft/min (0.63 m/s) where the rise exceeds 20 ft, and 100 ft/min where rise is 20 ft or less.

  • Escalator rated load is computed as 2 persons per 16 in (400 mm) of nominal width per step band segment; the code assumes 50% occupancy for capacity-based calculations.

  • Escalator clearance: minimum 7 ft (2.13 m) vertical clearance above the step band to any obstruction, and 2 ft 4 in (711 mm) between handrail centerlines minimum.

  • Machine-room and control-space access doors must be self-closing and self-locking, open outward, and be at least 30 in (762 mm) wide by 6 ft 8 in (2.03 m) high.

Quick reference

Electrical Theory, Circuits, and Motor Controls

  • Ohm's law: E = I x R; power in a DC or resistive circuit: P = E x I = I^2 R = E^2 / R.

  • Three-phase power: P (watts) = 1.732 x E_line x I_line x power factor; synchronous speed N = 120f / P where P is pole count.

  • Motor slip: percent slip = (N_sync - N_measured) / N_sync x 100; typical NEMA Design B induction motors run 2-4% slip at rated load.

  • Across-the-line starting draws roughly 6x nameplate full-load current; wye-delta and reduced-voltage starters lower inrush at the cost of torque.

  • A dynamic braking resistor converts motor kinetic energy to heat during deceleration; the resistor's duty rating, not its ohmic value alone, sets its thermal limit.

  • NEMA contactor sizing is by horsepower rating and utilization category (AC-3 for squirrel-cage motor starting), not just by amp rating.

  • A ground-fault circuit must trip at 5 mA +/- 1 mA for personnel protection; equipment GFCI in elevator circuits is typically set at 30 mA or higher per code.

  • Variable-frequency drives require shielded motor cable with the shield grounded at the drive end; long cable runs cause reflected-wave overvoltage at the motor terminals.

Quick reference

Mechanical Components, Hoisting, and Roping Systems

  • Traction ratio = total load on the sheave divided by the lesser rope tension; 1:1 roping has a ratio of 1, 2:1 has 2, and higher ratios reduce rope load but double rope travel.

  • Suspension rope safety factor: at least 12 for traction elevators with rated speed above 50 ft/min, and at least 16 for drum-type machines per A17.1.

  • Minimum number of suspension ropes is 3 for traction elevators; each rope must be independently terminated and equalized.

  • Rope construction for elevators is typically 6x19 or 8x19 seale independent wire rope core (IWRC); fiber-core ropes are not permitted for traction suspension.

  • Sheave-to-rope diameter ratio must be at least 40:1 for traction machines; smaller ratios accelerate fatigue and require more frequent inspection.

  • Rope wear rejection: replace when diameter reduction exceeds the code limit (roughly 3% below nominal for 6-8 strand ropes) or when broken wires in one lay exceed the A17.1 table.

  • Counterweight equals car weight plus approximately 40-50% of rated load, balancing the system so the machine sees near-equal tension up and down.

  • Guide rail alignment tolerance is typically 1/8 in (3 mm) over 5 ft; misalignment causes roller or gib wear and car sway.

Quick reference

Safety Devices, Governors, and Braking Systems

  • Governor tripping speed is set between 115% and 140% of rated speed for car governors; the tripping speed must not exceed the value in the A17.1 table for the rated speed.

  • The safety (car or counterweight) must stop the car within the code's deceleration limit; the governor tripping speed and safety setting combine to produce this.

  • Instantaneous safeties are permitted only below the code's speed threshold (typically 200 ft/min for cars); above that, type A or type B progressive safeties are required.

  • The governor rope must be at least 1/4 in (6.4 mm) diameter and must be tensioned so the governor operates before the car reaches the pit buffers.

  • Buffers: oil buffers are required for rated speeds above 200 ft/min; spring buffers are permitted below that. Buffer stroke must match the code table for rated speed.

  • Brake torque must hold 125% of rated load; the brake is set by spring and released by magnet or hydraulic pressure, so loss of power applies the brake.

  • The brake must be a friction type with a self-engaging design; a brake that depends on electrical or hydraulic power to set is not permitted.

  • Final limit switches must be independent of the normal limit switches and must open the power circuit before the car or counterweight reaches the buffer.

Quick reference

Hydraulic Elevator Systems

  • Hydraulic elevators are limited to a maximum travel of about 60 ft (18.3 m) for in-ground cylinders and 50 ft (15.2 m) for holeless telescoping cylinders.

  • Rated speed of a hydraulic elevator is set by pump displacement and plunger area: v = Q / A, so doubling plunger area halves speed at the same flow.

  • The relief valve must be set to open at no more than 150% of the full-load pressure and must be tested with the car at rest and loaded.

  • The check valve holds the car when the pump stops; the lowering valve controls descent. Both must be tested for leakage and response time.

  • The pressure switch and rupture valve protect against line failure; the rupture valve must close when flow exceeds the design limit, stopping the car.

  • Hydraulic fluid temperature affects viscosity and speed; typical operating range is 60-140 F, and low temperature raises pressure and slows descent.

  • The cylinder must have a means to detect and remove air; trapped air causes spongy ride and can allow the car to drop when the pump stops.

  • The pit must have a drain or sump and the cylinder must be protected against corrosion; a failed cylinder casing leaks oil into the pit and is a code violation.

Quick reference

Maintenance, Inspection, and Testing Procedures

  • Periodic inspection intervals are set by the authority having jurisdiction; A17.2 inspection procedures cover car, machine room, pit, and hoistway, in that order.

  • Annual tests include: safety device test with rated load, governor tripping speed, buffer test, brake test, and relief valve test on hydraulic units.

  • Five-year tests include: safety device test at 125% of rated load and a full-load test of the machine and brake.

  • The governor tripping speed is measured with a tachometer at the governor or by the rope speed; record the measured speed and compare to the A17.1 table.

  • The safety test is performed by tripping the governor and observing the car stop; measure the stopping distance and check for even engagement of both safety blocks.

  • Escalator inspection: check step-to-skirt clearance (not more than 3/16 in per side), comb teeth engagement, handrail speed, and the stop switch operation.

  • Maintenance records must be kept for each unit and made available to the inspector; missing records are a common cause of failed inspections.

  • Tag-out/lock-out is required before any work in the hoistway or machine room; the mainline disconnect must be locked open and the key controlled by the mechanic.

Quick reference

Michigan Elevator Safety Rules and Licensing Regulations

  • Michigan elevator work is regulated by the Elevator Safety Board within the Department of Licensing and Regulatory Affairs (LARA); the board adopts ASME A17.1 and A17.3 by reference.

  • Elevator mechanic and elevator contractor licenses are issued by LARA; work must be performed by or under the direct supervision of a licensed elevator mechanic.

  • Continuing education is required to renew a mechanic license; the board sets the hours and approved course categories.

  • Permits are required before installing or altering an elevator; the contractor submits plans and the state inspects before the unit is placed in service.

  • Periodic inspections in Michigan are performed at intervals set by rule; the owner is responsible for arranging inspection and paying fees.

  • A certificate of operation must be posted in the elevator car or machine room and renewed annually after inspection.

  • Unlicensed elevator work is a violation subject to civil penalties and may result in the contractor's license suspension or revocation.

  • Appeals of board or department decisions go through the Michigan Administrative Hearing System; a request must be filed within the time stated in the department's notice.

Quick reference

Jobsite Safety, Rigging, and OSHA Practices

  • OSHA fall protection for general industry is triggered at 4 ft; in construction, at 6 ft. Elevator hoistway work uses fall protection at the pit and at the car top.

  • A full-body harness with lanyard and a rated anchor point is required for hoistway work; the anchor must support 5,000 lb per worker or be designed by a qualified person.

  • Rigging: the working load limit of a sling is its vertical rating reduced by the sling angle; at 30 degrees from horizontal, capacity drops to 50% of vertical.

  • Never exceed the rated capacity of a shackle, hook, or chain; hooks must have a functioning safety latch and be inspected before each lift.

  • Hoisting a car or counterweight requires a rated beam or hoist point and a load test before personnel work under it; never use the elevator machine as a rigging point.

  • Lockout/tagout (29 CFR 1910.147) applies to elevator maintenance: isolate all energy sources, verify zero energy, and apply personal locks.

  • Confined-space entry rules apply to pits with limited access; test for oxygen, combustible gas, and hydrogen sulfide before entry where applicable.

  • Housekeeping: keep the pit and machine room clear of oil, tools, and debris; oil on the pit floor is a slip hazard and a fire hazard.