MO Water/Wastewater Operator flashcards
MO Water/Wastewater Operator · Build recall with a focused review session.
32 cards. Read the term and the definition here. The deck at the top of this page is optional.
- CT value
- Product of disinfectant residual concentration in mg/L and effective contact time in minutes; required CT increases at lower temperature and higher pH for free chlorine.
- Chlorine demand
- The difference between the chlorine dose applied and the free chlorine residual remaining after a defined contact time; it reflects oxidizable material in the water.
- Turbidity limit
- Under the Surface Water Treatment Rule, combined filter effluent must be 0.3 NTU or less in 95% of monthly samples and never exceed 1 NTU.
- Jar test
- Laboratory procedure that mixes raw water with varying coagulant doses and settling times to identify the optimum coagulant dose and pH for treatment.
- Filter loading rate
- Flow through a filter divided by its surface area, usually expressed in gpm/ft²; rapid sand filters typically operate between 2 and 5 gpm/ft².
- Backwash bed expansion
- The percentage increase in filter media depth during backwash; rapid sand filters are typically expanded 20 to 30 percent to release trapped solids.
- Langelier Saturation Index
- A calculated value comparing water pH to its calcium carbonate saturation pH; near zero is balanced, negative is corrosive, positive is scale-forming.
- Giardia inactivation credit
- Log removal credit granted for Giardia based on disinfectant type, residual, contact time, pH, and temperature; UV or ozone required for Cryptosporidium credit.
- Minimum distribution residual
- Missouri requires at least 0.2 mg/L free chlorine or 0.5 mg/L chloramine residual at points of entry and throughout the distribution system.
- Twenty psi rule
- Distribution pressure must remain at or above 20 psi at all points; a drop below this during a main break or pump failure triggers a boil order.
- Water horsepower
- Theoretical power to move water, calculated as (gpm × head in feet) ÷ 3960; brake horsepower equals water horsepower divided by pump efficiency.
- Tank detention time
- Storage volume divided by flow rate; for example, a 500,000-gallon tank at 1,000 gpm provides 500 minutes of detention.
- Hydrant flow test
- Field test measuring static pressure, residual pressure, and pitot pressure to estimate available fire flow; 20 psi residual is the standard reference point.
- Total coliform positive
- A routine positive total coliform sample requires repeat samples; an E. coli-positive or repeat-positive result requires public notice within 24 hours.
- Air gap backflow prevention
- A physical separation between the potable water outlet and the flood-level rim of a receiving vessel; the only true backflow prevention method.
- Pipe velocity calculation
- Flow divided by cross-sectional area; convert gpm to cfs by dividing by 448.8, then divide by area in square feet to get feet per second.
- BOD5
- Five-day biochemical oxygen demand measured at 20°C; typical domestic wastewater influent is about 200 to 250 mg/L BOD and similar TSS.
- F/M ratio
- Food-to-microorganism ratio: pounds of BOD applied per day divided by pounds of MLVSS in aeration; conventional activated sludge runs 0.2 to 0.5.
- MCRT
- Mean cell residence time, or sludge age: pounds of MLSS in aeration divided by pounds of solids leaving the system per day.
- Solids loading rate
- Pounds of solids applied per day per 1,000 square feet of clarifier surface; typical secondary clarifier design is 12 to 30 lbs/day/1,000 ft².
- Sludge volume index
- Volume in milliliters occupied by one gram of sludge after 30 minutes of settling; values above 150 indicate poor settling and possible bulking.
- Return activated sludge rate
- Flow of settled sludge returned from the clarifier to the aeration basin, typically 50 to 150 percent of influent flow to maintain MLSS.
- Mesophilic digestion
- Anaerobic digestion at about 95 to 98°F that reduces volatile solids and produces methane; temperature swings upset the process.
- Wastewater fecal coliform limit
- Missouri typically requires a monthly geometric mean of 200 fecal coliform per 100 mL in disinfected effluent; ammonia raises chlorine demand.
- Minimum sewer slope
- An 8-inch gravity sewer typically requires about 0.40 percent slope; smaller pipe needs steeper slopes and larger pipe can be flatter.
- Manning's equation
- Velocity = (1.486/n) × R^(2/3) × S^(1/2), where n is about 0.013 for new vitrified clay or PVC and R is hydraulic radius.
- Self-cleansing velocity
- A flow velocity of about 2 feet per second that keeps solids suspended and moving; lower velocities allow deposition and eventual blockage.
- Infiltration versus inflow
- Infiltration is groundwater entering through pipe defects and joints; inflow is direct stormwater entering through manholes, roof drains, or illegal connections.
- Wet well detention time
- Wet well volume divided by pump flow; should stay under about 30 minutes to prevent septic conditions, odor, and corrosion from sulfide.
- Confined space entry testing
- Before entry, test atmosphere for oxygen between 19.5 and 23.5 percent, LEL below 10 percent, and hydrogen sulfide below 10 ppm.
- Smoke testing
- Blowing non-toxic smoke into a sewer to reveal inflow sources, illegal connections, and broken pipe by observing where smoke escapes to the surface.
- CCTV sewer inspection
- Closed-circuit television camera passed through a sewer to record condition, cracks, roots, and offsets; results are graded on a 1 to 5 condition scale.