MSCE Woodwork flashcards
MSCE Woodwork · Build recall with a focused review session.
33 cards. Read the term and the definition here. The deck at the top of this page is optional.
- Fall Protection Threshold
- In general construction, fall protection is required at heights of 6 feet or more above a lower level. Guardrails, safety nets, and personal fall-arrest systems are acceptable systems.
- Kickback
- The sudden violent ejection of a workpiece back toward the operator, common on table and radial-arm saws. A riving knife, splitter, and anti-kickback pawls reduce the risk.
- GFCI Protection
- A ground-fault circuit interrupter trips when current leaks to ground. On construction sites it must protect 120-volt, 15- and 20-ampere receptacles not part of a permanent installation.
- Ladder 4:1 Rule
- For every 4 feet of working height, the ladder base is set out 1 foot from the wall. Extension ladders should extend at least 3 feet above the landing.
- Nominal Versus Dressed Lumber
- Nominal size is the rough name (2x4); dressed size is the finished dimension (1-1/2 x 3-1/2 in). Surfacing and drying remove roughly 1/2 in from thickness and width.
- Moisture Content Formula
- MC equals (wet weight minus oven-dry weight) divided by oven-dry weight, times 100. It is expressed as a percentage of the oven-dry mass of the wood.
- Fiber Saturation Point
- The moisture content at which cell walls are fully saturated but free water is absent, about 28-30%. Below this point, wood begins to shrink as it dries.
- Equilibrium Moisture Content
- The moisture content at which wood neither gains nor loses moisture to surrounding air. It tracks relative humidity and temperature, roughly 6-8% in heated interiors.
- Penny Size (Nail)
- A historical nail sizing system. Common conversions: 8d equals 2-1/2 in, 10d equals 3 in, 16d equals 3-1/2 in, and 20d equals 4 in.
- Galvanized Fasteners
- Zinc-coated fasteners required when connecting preservative-treated lumber. ACQ and CA treatments are corrosive; hot-dip galvanized or stainless steel is specified for exterior and wet use.
- Dado Joint
- A rectangular groove cut across the grain of one member to receive the end or edge of another. It provides alignment and load-bearing surface for shelves and cabinet sides.
- Mortise and Tenon
- A projecting tenon on one member fits into a matching mortise cut in the other. The joint resists racking and is common in timber framing and fine furniture.
- Stud Spacing
- The center-to-center distance between wall studs, typically 16 or 24 inches. Spacing must match the span rating of the sheathing and the load requirements of the wall.
- Cripple Stud
- A short stud placed above a header over a door or window opening, or below a window sill. It carries vertical load and supports sheathing and trim.
- Header
- A horizontal structural member spanning an opening to carry loads above it. Size depends on span, load, and species; doubled members are common over wide openings.
- Rim Joist
- The outermost joist running perpendicular to the floor joists, capping their ends. It ties the floor frame together and provides a nailing surface for sheathing.
- Roof Slope
- Rise over run, expressed as inches of rise per 12 inches of horizontal run. A 6/12 roof rises 6 inches for every 12 inches of horizontal travel.
- Common Rafter Length
- The line length equals the square root of run squared plus rise squared. Add the overhang and subtract the ridge allowance to obtain the cut length.
- Collar Tie
- A horizontal member connecting opposing rafters in the upper third of the span. It resists rafter separation and helps stiffen the roof frame.
- Ice Barrier
- A self-adhering waterproof membrane applied along the eaves before underlayment. It prevents water backup from ice dams in cold climates, extending about 24 inches inside the wall line.
- Unit Rise
- The height of a single step, equal to total rise divided by the number of risers. The IRC caps it at 7-3/4 inches for residential stairs.
- Unit Tread Run
- The horizontal depth of a single tread, equal to total run divided by the number of treads. Treads number one fewer than risers.
- Stringer Length
- The diagonal length of the stair carriage, equal to the square root of total rise squared plus total run squared. It sets the layout of the cut stringer.
- Headroom Clearance
- The vertical distance from the stair nosing line to the ceiling or obstruction above. Residential code requires a minimum of 6 feet 8 inches.
- Sill Pan Flashing
- A preformed or site-built flashing that lines the bottom of a rough window opening. End dams direct any water that enters back out to the exterior.
- Shingle-Lap Flashing
- A flashing sequence in which upper layers overlap lower layers so water flows outward and downward. The weather-resistive barrier laps over the window flange at the top and sides.
- Window U-Factor
- The rate of heat loss through a window assembly. Lower values mean better insulating performance; it is the inverse of R-value.
- Drywall Screw Spacing
- Screws are spaced 12 inches on center on ceilings and 16 inches on center on walls. Fasteners stay at least 3/8 inch from panel edges to avoid crushing the gypsum core.
- Door Rough Opening
- The framed opening that receives a door and jamb. For a standard interior door it is door width plus 2 inches and door height plus 2-1/2 inches.
- Board Foot
- A volume of lumber equal to 1 inch thick, 12 inches wide, and 12 inches long. It is computed as thickness times width times length divided by 12.
- Drawing Scale
- The ratio between a dimension on paper and the actual dimension. At 1/4 inch equals 1 foot, 1/4 inch on the drawing represents 12 inches of real construction.
- Egress Window
- An emergency escape opening required in sleeping rooms. It needs at least 5.7 square feet of clear area, 24 inches of height, 20 inches of width, and a 44-inch maximum sill.
- Certificate of Occupancy
- A document issued by the building authority after final inspection confirms the structure complies with approved plans and code. It legally permits occupancy of the building.