The process by which a semiconductor material converts absorbed light energy directly into direct-current electricity, producing a voltage difference across the cell's internal junction when photons free electrons.

Related: PV cell, Irradiance
PV cell

The smallest electricity-producing unit in a module, typically a thin wafer of silicon with a built-in electric field that separates light-generated charge carriers and delivers current to external terminals.

Related: Photovoltaic effect, PV module
PV module

A factory-assembled, weather-sealed package of interconnected PV cells laminated behind glass, providing a rated voltage and current and the physical unit mounted on a system.

Related: PV cell, PV array
PV array

The complete assembly of one or more PV modules together with their support structure and wiring, treated as a single generating unit in code and design calculations.

Related: PV module, String
Irradiance

The instantaneous power density of sunlight falling on a surface, measured in watts per square meter; standard test conditions use 1000 W/m² as the reference value.

Related: Standard Test Conditions, Insolation
Insolation

The cumulative solar energy received per unit area over a period such as a day, expressed in kilowatt-hours per square meter; it drives energy-yield estimates rather than instantaneous power.

Related: Irradiance, Capacity factor
Standard Test Conditions (STC)

The laboratory reference set of 1000 W/m² irradiance, 25 °C cell temperature, and a defined air-mass spectrum, used to rate module power and compare products on a common basis.

Related: Irradiance, Temperature coefficient
Temperature coefficient of power

The percentage change in module maximum power for each degree Celsius the cell temperature departs from 25 °C; it is negative, so hot modules produce less than their rated output.

Related: Standard Test Conditions, Cell temperature
Open-circuit voltage (Voc)

The maximum voltage a module or string develops with no load connected, used for code voltage-limit and equipment-rating checks because it rises as cell temperature falls.

Related: Short-circuit current, Maximum system voltage
Short-circuit current (Isc)

The current that flows when module output terminals are connected through a near-zero resistance; it sets the basis for conductor ampacity and overcurrent device sizing.

Related: Open-circuit voltage (Voc), Maximum power point
Maximum power point (MPP)

The operating point on a module's current-voltage curve where the product of current and voltage is greatest; inverters continuously track this point to maximize harvest.

Related: Maximum power point tracking, Short-circuit current (Isc)
Maximum power point tracking (MPPT)

An inverter or charge-controller function that continuously adjusts its operating voltage to keep the array at its maximum power point as irradiance and temperature change.

Related: Maximum power point (MPP), String inverter
Fill factor

The ratio of a module's maximum power to the product of its open-circuit voltage and short-circuit current, indicating how square and efficient its current-voltage curve is.

Related: Maximum power point (MPP), PV module
String

A series connection of PV modules whose voltages add while the same current flows through each, forming the basic building block of most array wiring.

Related: PV array, String inverter
String inverter

A central inverter that receives direct current from one or more series strings and converts it to grid-compatible alternating current, typically mounted near the array or service equipment.

Related: String, Maximum power point tracking (MPPT)
Microinverter

A small inverter mounted at or near a single module that converts that module's direct current to alternating current locally, enabling per-module tracking and simplifying array expansion.

Related: String inverter, Rapid shutdown
Rapid shutdown

A code-required function that reduces conductor voltage at the array to a safe level within a specified time after activation, protecting firefighters and service personnel.

Related: Microinverter, Disconnect
Maximum system voltage

The highest voltage a module or system is rated to withstand, marked on the label; string design must keep cold-temperature open-circuit voltage below this value and code limits.

Related: Open-circuit voltage (Voc), Voltage drop
Ampacity

The maximum current a conductor can carry continuously under stated conditions without exceeding its temperature rating, adjusted for ambient temperature and conduit fill.

Related: Overcurrent protection device, Conductor sizing
Overcurrent protection device (OCPD)

A fuse or circuit breaker that interrupts current above its rating to protect conductors and equipment from overheating or fault damage; PV source circuits often require such devices.

Related: Ampacity, Ground-fault protection
Ground-fault protection

A system that detects current leaking from energized conductors to ground and interrupts the circuit, required for many PV installations to reduce shock and fire hazards.

Related: Overcurrent protection device (OCPD), Equipment grounding conductor
Equipment grounding conductor

The conductor that bonds non-current-carrying metal parts of modules, racking, and enclosures together and to the grounding electrode system, providing a low-impedance fault path.

Related: Ground-fault protection, Bonding
Bonding

The permanent joining of metal parts to form an electrically conductive path that ensures electrical continuity and safe fault-current flow between equipment and the grounding system.

Related: Equipment grounding conductor, Ground-fault protection
Disconnect

A switch or device that isolates a circuit or equipment from its source of energy so work can proceed safely; PV systems need clearly labeled disconnects for array, inverter, and utility sides.

Related: Rapid shutdown, Lockout/tagout
Voltage drop

The reduction in voltage along conductors caused by resistance and current flow; excessive drop wastes energy and can cause equipment misoperation, so designers keep it within a target percentage.

Related: Ampacity, Conductor sizing
Conductor sizing

Selecting wire gauge so that ampacity, after correction factors, meets or exceeds the required continuous current while keeping voltage drop and termination temperature limits acceptable.

Related: Ampacity, Voltage drop
Interconnection

The physical and contractual connection of a PV system to the utility grid or to a building's electrical distribution, governed by utility rules and code requirements for protection and metering.

Related: Net metering, Grid-tied inverter
Grid-tied inverter

An inverter designed to synchronize with and export power to the utility grid, including anti-islanding protection that stops output when the grid is absent.

Related: Interconnection, Anti-islanding
Anti-islanding

A protective function that detects loss of utility voltage or abnormal grid conditions and disconnects the inverter, preventing the PV system from energizing an isolated grid section.

Related: Grid-tied inverter, Interconnection
Net metering

A billing arrangement that credits a customer for exported PV electricity, typically by allowing the meter to run backward or by offsetting consumption across a billing period.

Related: Interconnection, Grid-tied inverter
Capacity factor

The ratio of a system's actual energy production over a period to the energy it would have produced running at rated power continuously, reflecting weather, soiling, and availability.

Related: Insolation, Performance ratio
Performance ratio

The ratio of a system's actual energy yield to the theoretical yield from measured irradiance, capturing losses such as temperature, soiling, wiring, and inverter inefficiency.

Related: Capacity factor, Soiling
Soiling

Accumulation of dust, pollen, bird droppings, or other deposits on module glass that blocks light and reduces output; heavy soiling can also create hot spots.

Related: Hot spot, Performance ratio
Hot spot

A localized overheated area on a cell caused by shading, soiling, or damage that forces the cell to dissipate power, potentially degrading the module or posing a fire risk.

Related: Soiling, Bypass diode
Bypass diode

A diode wired across a group of cells inside a module that provides an alternate current path when those cells are shaded or faulty, limiting hot-spot heating and power loss.

Related: Hot spot, Shading
Shading

Blocking of sunlight on modules by trees, buildings, or adjacent rows; partial shading disproportionately reduces string output and must be analyzed during site assessment and layout.

Related: Bypass diode, Hot spot
Lockout/tagout

An OSHA-required procedure for de-energizing equipment, applying a personal lock and tag, and verifying absence of voltage before service work begins.

Related: Disconnect, Personal protective equipment
Personal protective equipment (PPE)

Employer-provided gear such as gloves, eye protection, hard hats, and arc-rated clothing that shields workers from electrical, fall, and physical hazards on the job site.

Related: Lockout/tagout, Fall protection
Fall protection

Systems such as guardrails, personal fall arrest harnesses, and anchor points required by OSHA when workers are exposed to falls from roofs or elevated structures.

Related: Personal protective equipment (PPE), Ladder safety
Ladder safety

OSHA-based practices for selecting, setting, and climbing ladders, including the four-to-one angle rule, three-point contact, and securing the ladder before roof access.

Related: Fall protection, Personal protective equipment (PPE)