NABCEP PVIS key terms
NABCEP PVIS · Get comfortable with the vocabulary.
- Standard Test Conditions (STC)
- Related: Irradiance, Temperature Coefficient of Power, Nameplate Rating
Laboratory reference conditions for rating a PV module: 1000 W/m² irradiance, 25°C cell temperature, and an AM 1.5G spectrum. Nameplate power on a module's label is measured here, so real-world output usually differs.
- Irradiance
- Related: Air Mass, Standard Test Conditions (STC), Plane of Array Irradiance
The instantaneous power density of sunlight falling on a surface, expressed in watts per square meter. It drives module current, so a doubling of irradiance roughly doubles output current while voltage changes only slightly.
- Air Mass (AM)
- Related: Irradiance, Standard Test Conditions (STC)
A measure of how much atmosphere sunlight passes through before reaching a surface, with AM 1.0 at the sun directly overhead. Higher air mass means more scattering and absorption, shifting the spectrum and reducing usable energy.
- Plane of Array Irradiance
- Related: Irradiance, Tilt Angle, Azimuth
The irradiance measured in the plane of the modules, accounting for tilt and orientation rather than a horizontal sensor. It is the value that actually drives array production and is used in performance modeling.
- Azimuth
- Related: Tilt Angle, Plane of Array Irradiance
The compass direction a module surface faces, usually given in degrees from true north. In the northern hemisphere, true south is optimal for annual yield in most fixed-tilt designs, though utility load profiles may favor other orientations.
- Tilt Angle
- Related: Azimuth, Plane of Array Irradiance
The angle between a module's surface and horizontal. It sets how much beam irradiance the array captures seasonally and affects snow shedding and self-cleaning by rain.
- Open-Circuit Voltage (Voc)
- Related: Short-Circuit Current (Isc), Temperature Coefficient of Voltage, Maximum System Voltage
The maximum voltage a module or string produces with no load connected, measured in volts. It rises as cell temperature falls, so cold-weather design must use the temperature-corrected Voc to stay within equipment voltage limits.
- Short-Circuit Current (Isc)
- Related: Open-Circuit Voltage (Voc), Maximum Power Point (MPP)
The current that flows when module terminals are connected through a near-zero resistance, measured in amperes. It scales with irradiance and is used to size conductors and overcurrent protection.
- Maximum Power Point (MPP)
- Related: Fill Factor, Maximum Power Point Tracking (MPPT), Open-Circuit Voltage (Voc)
The operating point on a module's current-voltage curve where the product of current and voltage is greatest. Inverters continuously track this point because it shifts with irradiance and temperature.
- Fill Factor
- Related: Maximum Power Point (MPP), Short-Circuit Current (Isc)
The ratio of a module's maximum power to the product of its open-circuit voltage and short-circuit current. A high fill factor indicates a sharp, square I-V curve and lower series resistance losses.
- Temperature Coefficient of Power
- Related: Standard Test Conditions (STC), Nominal Operating Cell Temperature (NOCT)
The percentage change in module power for each degree Celsius away from 25°C cell temperature. It is typically negative, meaning output falls as cells heat up in the field.
- Temperature Coefficient of Voltage
- Related: Open-Circuit Voltage (Voc), Maximum System Voltage
The rate at which open-circuit voltage changes per degree Celsius, usually a negative value per cell. Because voltage climbs in cold conditions, it governs the worst-case maximum string voltage used in design.
- Nominal Operating Cell Temperature (NOCT)
- Related: Temperature Coefficient of Power, Standard Test Conditions (STC)
The cell temperature a module reaches under defined field-like conditions: 800 W/m² irradiance, 20°C ambient air, and 1 m/s wind. It helps estimate real operating temperatures and derated output.
- Bypass Diode
- Related: Blocking Diode, Hot Spot, String
A diode wired across a group of cells inside a module that provides an alternate path for current when those cells are shaded or faulty. It limits hot-spot heating and preserves string output during partial shade.
- Blocking Diode
- Related: Bypass Diode, String
A diode placed in series with a module or string to prevent reverse current from flowing back into it, for example from a parallel string or battery at night. It costs a small forward voltage drop during normal operation.
- Hot Spot
- Related: Bypass Diode, Potential Induced Degradation (PID)
A localized overheated area in a module caused when a shaded or damaged cell is forced to dissipate power produced by neighboring cells. Persistent hot spots can degrade encapsulant and create safety hazards.
- Potential Induced Degradation (PID)
- Related: Hot Spot, Maximum System Voltage
A voltage-driven degradation mechanism in which current leaks through the module packaging to the grounded frame, especially at high system voltages. It reduces power output and can often be mitigated by grounding or voltage-limiting strategies.
- String
- Related: Open-Circuit Voltage (Voc), Maximum System Voltage, Source Circuit
A series connection of PV modules that adds their voltages while sharing the same current. String length must be set so that cold-weather open-circuit voltage stays below equipment ratings and hot-weather voltage stays above inverter start thresholds.
- Maximum System Voltage
- Related: Open-Circuit Voltage (Voc), String, Temperature Coefficient of Voltage
The highest voltage a module or system component is rated to withstand, commonly 600 V, 1000 V, or 1500 V. Designers must confirm that cold-temperature string voltage never exceeds this rating.
- Maximum Power Point Tracking (MPPT)
- Related: Maximum Power Point (MPP), String Inverter
An inverter function that continuously adjusts its operating voltage to keep the array at its maximum power point as irradiance and temperature change. Multiple MPPT inputs allow strings with different orientations to operate independently.
- String Inverter
- Related: Microinverter, Maximum Power Point Tracking (MPPT), String
A central inverter that converts DC from one or more parallel strings to AC grid power. It relies on the array's string configuration and MPPT channels to optimize harvest.
- Microinverter
- Related: String Inverter, Maximum Power Point Tracking (MPPT)
A small inverter mounted at each module that converts DC to AC locally. It provides per-module MPPT and reduces the effect of shading, at higher cost and with more rooftop electronics.
- Rapid Shutdown
- Related: Microinverter, Disconnect
A code-required function that reduces conductor voltage at the array to a safe level for firefighters within a specified time after activation. It is typically achieved with module-level electronics or a shunt trip device.
- Grounding Electrode Conductor (GEC)
- Related: Equipment Grounding Conductor (EGC), Ground Fault
The conductor that connects the grounding electrode system to the service equipment or system grounding point. It provides a low-impedance path to earth for fault current and lightning-related surges.
- Equipment Grounding Conductor (EGC)
- Related: Grounding Electrode Conductor (GEC), Ground Fault
A conductor that bonds non-current-carrying metal parts such as module frames, racking, and enclosures together and back to the grounding point. It ensures fault current trips protective devices.
- Ground Fault
- Related: Ground Fault Detection and Interruption (GFDI), Equipment Grounding Conductor (EGC)
An unintended current path from an energized conductor to earth or to grounded metal. PV systems require ground-fault protection that detects the fault and disconnects or isolates the faulted circuit.
- Ground Fault Detection and Interruption (GFDI)
- Related: Ground Fault, Rapid Shutdown
A protective circuit in a PV system that senses leakage current to ground and interrupts the faulted circuit. It is a required safety feature for many grounded and ungrounded array configurations.
- Disconnect
- Related: Rapid Shutdown, Lockout/Tagout
A switch or device that isolates equipment from its power source for service or emergency. PV systems need clearly labeled DC and AC disconnects accessible to service personnel and first responders.
- Lockout/Tagout
- Related: Disconnect, Arc Flash
A safety procedure that physically locks an energy source in the off position and tags it to prevent accidental re-energization during service. It is essential when working on PV circuits that remain energized in daylight.
- Arc Flash
- Related: Arc-Fault Circuit Interruption (AFCI), Lockout/Tagout
A dangerous release of energy caused by an electrical arc between conductors or to ground. PV systems can sustain arcs because the array remains energized whenever illuminated, so arc-fault protection and safe work practices are required.
- Arc-Fault Circuit Interruption (AFCI)
- Related: Arc Flash, Ground Fault Detection and Interruption (GFDI)
A protective function that detects the signature of a dangerous series arc in DC wiring and interrupts the circuit. It reduces fire risk from loose connections or damaged conductors in PV arrays.
- Fall Protection
- Related: Lockout/Tagout
Systems and practices that prevent workers from falling from roofs or elevated structures, such as harnesses, anchors, guardrails, and ladders. OSHA-style requirements apply to residential and commercial rooftop installation.
- Energy Payback Time
- Related: Levelized Cost of Energy (LCOE), Performance Ratio
The period a PV system must operate to generate the energy consumed in manufacturing, transporting, and installing it. It is a sustainability metric, not a financial one, and is typically a few years for modern modules.
- Levelized Cost of Energy (LCOE)
- Related: Performance Ratio, Energy Payback Time
The average net present cost of generating one unit of electricity over a system's life, accounting for capital, financing, operations, and production. It allows comparison of PV with other generation sources.
- Performance Ratio
- Related: Levelized Cost of Energy (LCOE), Soiling
The ratio of a system's actual energy output to the output it would produce at STC irradiance for the same period. It captures temperature, soiling, wiring, and inverter losses and is a standard commissioning and monitoring metric.
- Soiling
- Related: Performance Ratio, Irradiance
Accumulation of dust, pollen, bird droppings, or snow on module glass that blocks irradiance and reduces output. Regular cleaning or tilt-based self-cleaning mitigates the loss, which varies strongly by location.
- Shading Analysis
- Related: Bypass Diode, Plane of Array Irradiance, String
The process of identifying obstructions that will cast shadows on an array and quantifying their effect on production. Tools include solar pathfinders, software modeling, and site observation at different times of year.
- Source Circuit
- Related: String, Maximum System Voltage
The DC circuit conductors connecting a PV module or string to the next combiner or inverter input. Its ampacity and overcurrent protection must account for continuous current and irradiance-enhanced current.
- Nameplate Rating
- Related: Standard Test Conditions (STC), Performance Ratio
The manufacturer's labeled power, voltage, and current values for a module or inverter under specified test conditions. Designers apply temperature, soiling, and mismatch derates to translate nameplate values into expected field performance.