Irradiance

The instantaneous power density of sunlight falling on a surface, typically expressed in watts per square meter. It drives module output at any given moment and is measured with a pyranometer or reference cell.

Related: Irradiation, Peak Sun Hours, Standard Test Conditions
Irradiation

The accumulated solar energy delivered per unit area over a period of time, such as a day or year, usually expressed in kilowatt-hours per square meter. It is the energy quantity behind production estimates.

Related: Irradiance, Peak Sun Hours, Performance Ratio
Peak Sun Hours

The number of hours per day at 1,000 W/m² irradiance that would deliver the same total energy as the actual sun over that day. A convenient way to compare sites and size arrays.

Related: Irradiation, Irradiance, Insolation
Standard Test Conditions

The laboratory reference conditions of 1,000 W/m² irradiance, 25°C cell temperature, and a specified air mass spectrum used to rate module nameplate power. Real-world output rarely matches these values.

Related: Nameplate Rating, Temperature Coefficient, Irradiance
Nameplate Rating

The direct-current power a module is warranted to produce under Standard Test Conditions, printed on its label and used as the basis for system sizing and incentive calculations.

Related: Standard Test Conditions, Temperature Coefficient, Derate Factor
Temperature Coefficient of Power

The percentage change in module power for each degree Celsius of cell temperature change, usually negative. It explains why hot rooftop arrays produce less than their rated output.

Related: Nameplate Rating, Cell Temperature, Derate Factor
Cell Temperature

The actual operating temperature of the photovoltaic cells, which runs well above ambient air temperature because of absorbed sunlight and restricted airflow behind the module. It directly affects voltage and power output.

Related: Temperature Coefficient of Power, NOCT, Derate Factor
NOCT

Nominal Operating Cell Temperature: the cell temperature reached under 800 W/m² irradiance, 20°C ambient air, and specified wind speed. It lets designers estimate real operating temperatures from ambient conditions.

Related: Cell Temperature, Temperature Coefficient of Power
Derate Factor

A multiplier accounting for losses that reduce a system's output below the module nameplate value, including temperature, wiring, soiling, inverter, and mismatch losses. Multiplying all derates gives overall system efficiency.

Related: Performance Ratio, Nameplate Rating, Inverter Efficiency
Performance Ratio

The ratio of actual delivered energy to the theoretical energy the array would produce at its rated power under the same irradiance. It normalizes output and is a standard quality benchmark for completed systems.

Related: Derate Factor, Irradiation, Production Estimate
Production Estimate

A forecast of annual or monthly energy output for a proposed system, built from site irradiance, array size, and loss factors. It underpins savings projections, payback analysis, and customer expectations.

Related: Performance Ratio, Irradiation, Derate Factor
Shading Analysis

The process of identifying obstructions whose shadows fall on an array and quantifying the energy lost. It may use a site survey tool, solar path chart, or modeling software and often drives module layout decisions.

Related: Solar Access, Bypass Diode, String Sizing
Solar Access

The degree to which a location receives unobstructed sunlight over the year, considering trees, buildings, and terrain. It is a primary screening criterion for array placement.

Related: Shading Analysis, Azimuth, Tilt Angle
Azimuth

The compass direction a module surface faces, usually measured in degrees clockwise from true north. In the northern hemisphere, a due-south azimuth generally maximizes annual energy collection.

Related: Tilt Angle, Solar Access
Tilt Angle

The angle between the module surface and horizontal. It affects how much irradiance the array captures and how well rain cleans the glass, and is often set near the site latitude.

Related: Azimuth, Solar Access
Insolation

A general term for the solar radiation received at a location, often used interchangeably with irradiation in sales conversations. It describes the solar resource available for a project.

Related: Irradiation, Peak Sun Hours
Bypass Diode

A diode inside a module that provides an alternate current path around shaded or faulty cell groups, limiting hot spots and power loss. Its presence affects how partial shading degrades array output.

Related: Shading Analysis, String Sizing
Inverter Efficiency

The ratio of alternating-current power delivered to the grid or loads to the direct-current power drawn from the array. It varies with load and is a key input to production estimates.

Related: Derate Factor, Performance Ratio
Load Profile

A record of a customer's electricity consumption over time, showing hourly, daily, and seasonal patterns. Comparing it with solar production reveals how much generation is consumed on site versus exported.

Related: Net Metering, Self-Consumption, Time-of-Use Rate
Net Metering

A billing arrangement that credits customers for electricity exported to the grid, often at the retail rate, offsetting power drawn at other times. Rules vary widely by utility and jurisdiction.

Related: Load Profile, Interconnection, Time-of-Use Rate
Time-of-Use Rate

An electricity tariff in which the price per kilowatt-hour changes by time of day and season. It can make solar energy more valuable if production aligns with expensive periods.

Related: Load Profile, Net Metering, Demand Charge
Demand Charge

A utility charge based on the highest interval of power drawn during a billing period, common for commercial accounts. Solar can reduce it only if it reliably cuts peak demand.

Related: Time-of-Use Rate, Load Profile
Self-Consumption

The share of solar generation used directly at the site rather than exported. Higher self-consumption usually improves project economics when export credits are low.

Related: Load Profile, Net Metering
Interconnection

The technical and administrative process of connecting a generating system to the utility grid, including application, review, and approval. It determines timeline and possible equipment upgrades.

Related: Net Metering, Load Profile
Incentive

A financial benefit such as a tax credit, rebate, or grant that reduces the net cost of a solar purchase. Eligibility rules and timing affect the quoted customer price.

Related: Payback Period, Net Present Value, Power Purchase Agreement
Payback Period

The time required for cumulative savings and incentives to equal the initial system cost. Simple to explain to customers but ignores the time value of money and post-payback savings.

Related: Net Present Value, Incentive, Levelized Cost of Energy
Net Present Value

The value today of all future project cash flows, discounted at a chosen rate, minus the initial investment. A positive result indicates the project creates value over its life.

Related: Payback Period, Discount Rate, Levelized Cost of Energy
Discount Rate

The rate used to convert future cash flows into present value, reflecting the cost of capital or an investor's required return. Higher rates reduce the apparent value of long-term solar savings.

Related: Net Present Value, Levelized Cost of Energy
Levelized Cost of Energy

The average cost per kilowatt-hour of energy produced over a system's life, accounting for capital cost, incentives, operations, and output. It allows comparison with utility rates or other generation options.

Related: Net Present Value, Payback Period
Power Purchase Agreement

A contract in which a third party owns the solar system and the customer buys its output at an agreed rate, often with little or no upfront cost. Terms cover price escalation, duration, and end-of-term options.

Related: Incentive, Net Present Value, Lease
Lease

A financing arrangement in which a third party owns the system and the customer pays a fixed monthly amount for its use. The customer typically receives the energy but not the tax benefits.

Related: Power Purchase Agreement, Incentive
String Sizing

Selecting the number of modules wired in series so that voltage stays within the inverter's window across expected temperature extremes. It protects equipment and maximizes harvest.

Related: Open-Circuit Voltage, Maximum Power Point, Temperature Coefficient of Power
Open-Circuit Voltage

The voltage measured across a module or string with no current flowing, which rises in cold weather. It sets the maximum voltage the inverter and conductors must safely withstand.

Related: String Sizing, Maximum Power Point
Maximum Power Point

The operating voltage and current combination at which a module delivers its greatest power under given conditions. Inverters continuously track this point as irradiance and temperature change.

Related: String Sizing, Open-Circuit Voltage, Inverter Efficiency
Site Survey

An on-site inspection gathering roof condition, dimensions, shading, structural, and electrical information needed to design and quote a system. It confirms or corrects assumptions made from remote imagery.

Related: Shading Analysis, Solar Access, Production Estimate
Proposal

The written offer presented to a customer describing system design, expected production, price, incentives, savings, warranties, and terms. It is the core sales deliverable and must match the final contract.

Related: Production Estimate, Incentive, Payback Period