NCCER Plumbing · Get comfortable with the vocabulary.

developed length

The total measured distance a pipe runs along its centerline, including all horizontal and vertical segments and changes of direction, measured before fittings are installed. Used to estimate material quantities and to size pipe for pressure loss.

Related: equivalent length, fixture unit, grade
equivalent length

A method of expressing the pressure loss caused by fittings and valves as an added length of straight pipe of the same size. Added to developed length so friction loss through the whole run can be calculated.

Related: developed length, pressure drop, friction loss
friction loss

The pressure lost as water moves through pipe, caused by the pipe wall and by turbulence at fittings. It increases with flow rate, pipe length, and roughness, and decreases with larger pipe diameter.

Related: pressure drop, equivalent length, velocity
pressure drop

The difference in pressure between two points in a piping system, usually caused by friction, elevation change, or a device in the line. Designers limit it so fixtures still receive adequate pressure.

Related: friction loss, static head, residual pressure
static head

The pressure created by the weight of a column of water at a given height, equal to about 0.434 psi per foot of elevation. Used to account for height differences between a supply source and fixtures.

Related: pressure drop, residual pressure, water hammer
residual pressure

The pressure remaining at a fixture or outlet while water is flowing. It must stay above the minimum required by code for the fixture to operate correctly and is checked during flow testing.

Related: static head, pressure drop, flow rate
flow rate

The volume of water passing a point in a piping system per unit of time, commonly expressed in gallons per minute. Used to size pipe, select pumps, and match supply to fixture demand.

Related: fixture unit, velocity, residual pressure
velocity

The speed at which water travels through a pipe, usually stated in feet per second. Excessive velocity causes noise, erosion, and water hammer; codes and good practice set upper limits for supply and drainage piping.

Related: flow rate, water hammer, friction loss
fixture unit

A unit of measure that assigns a relative load value to a plumbing fixture based on its probable flow demand. Fixture units are added together to size water supply and drainage systems for a building.

Related: flow rate, drainage fixture unit, developed length
drainage fixture unit

A value assigned to a fixture representing its probable discharge rate into a drainage system. Values are totaled to determine drain pipe size, trap size, and vent requirements for a building drain.

Related: fixture unit, trap arm, soil stack
water hammer

A loud banging or knocking in piping caused by a sudden stop in water flow, such as a quick-closing valve, producing a pressure surge. Controlled with air chambers, arrestors, or slower-closing valves.

Related: velocity, static head, air chamber
air chamber

A vertical capped pipe or manufactured device connected near a fixture that traps air to absorb pressure surges when flow stops. It reduces water hammer and protects pipe and fittings from shock.

Related: water hammer, shock absorber, velocity
grade

The slope of a drain pipe, expressed as fall per unit of length, such as one-quarter inch per foot. Proper grade lets waste flow by gravity while keeping liquid moving fast enough to carry solids.

Related: fall, developed length, trap arm
fall

The total vertical drop of a drain line over its run, calculated by multiplying the grade by the length. It must be checked so the pipe fits within available space and still drains properly.

Related: grade, developed length, drainage fixture unit
trap arm

The section of drain pipe between a fixture trap and the point where it connects to a branch or stack. Its length and slope are limited by code so the trap seal is not siphoned out.

Related: trap seal, drainage fixture unit, grade
trap seal

The depth of water held in a fixture trap that blocks sewer gas from entering the building. Common seals are two to four inches deep and must be protected by proper venting.

Related: trap arm, vent stack, siphonage
siphonage

The pulling of water out of a fixture trap by pressure differences in the drainage or vent system, which breaks the seal and allows sewer gas into the building. Prevented by correct venting and trap arm length.

Related: trap seal, vent stack, trap arm
vent stack

A vertical pipe that provides air to a drainage system and allows sewer gases to escape above the roof. It protects trap seals by equalizing pressure in the drain piping.

Related: trap seal, siphonage, stack vent
stack vent

The extension of a soil or waste stack above the highest fixture connection, continuing through the roof to open air. It vents the stack and helps maintain atmospheric pressure in the drainage system.

Related: vent stack, soil stack, trap seal
soil stack

The main vertical drain pipe that carries sewage containing fecal matter from water closets and other fixtures down to the building drain. It must be sized and vented according to the fixtures it serves.

Related: waste stack, stack vent, drainage fixture unit
waste stack

A vertical drain pipe that carries liquid waste from fixtures other than water closets, such as sinks and lavatories. It connects to the building drain and is vented to protect trap seals.

Related: soil stack, vent stack, drainage fixture unit
building drain

The lowest horizontal portion of a drainage system that receives waste from the stacks and carries it to the building sewer. It is usually located just inside or under the building foundation.

Related: building sewer, soil stack, grade
building sewer

The pipe that carries sewage from the building drain to the public sewer or private disposal system. It begins outside the building foundation and is typically owned and maintained by the property owner.

Related: building drain, grade, cleanout
cleanout

An accessible fitting with a removable cap installed on drainage piping so blockages can be cleared with a snake or rod. Codes require cleanouts at specified locations, such as the base of stacks and changes in direction.

Related: building drain, building sewer, trap arm
backflow

The unwanted reversal of water flow in a piping system, which can contaminate the potable supply. Prevented with air gaps, vacuum breakers, and backflow prevention assemblies selected for the hazard level.

Related: air gap, vacuum breaker, cross connection
cross connection

Any actual or potential link between a potable water system and a source of contamination or pollution. It must be eliminated or protected by an approved backflow prevention device.

Related: backflow, air gap, vacuum breaker
air gap

The unobstructed vertical distance between a water supply outlet and the flood level rim of the fixture it serves. It is the most reliable form of backflow protection because no mechanical parts are involved.

Related: backflow, cross connection, vacuum breaker
vacuum breaker

A device that opens to admit air and break a vacuum in piping, preventing back-siphonage of contaminated water into the supply. Common types include atmospheric and pressure vacuum breakers.

Related: backflow, cross connection, air gap
water service

The pipe and fittings that carry potable water from the water main or private source to the building. It includes the meter, valves, and the connection to the building's water distribution system.

Related: water main, meter, backflow
water main

A primary pipe in a public or private water distribution network that supplies individual water services. Its size and pressure determine the flow available to connected buildings.

Related: water service, residual pressure, flow rate
potable water

Water that is safe for human consumption and meets health-based quality standards. Plumbing codes require potable water for drinking, cooking, bathing, and other domestic uses.

Related: cross connection, backflow, water service
rough-in

The phase of plumbing work in which pipes, fittings, and supports are installed before walls, floors, and fixtures are finished. Inspections typically occur after rough-in and before covering the work.

Related: trim, flange, cleanout
trim

The finished, visible plumbing components installed after rough-in, such as faucets, spouts, escutcheons, and fixture trim plates. Trim work completes the system and is installed during final finishing.

Related: rough-in, flange, water closet
flange

A projecting rim or collar on a pipe or fitting used to make a connection or to support a fixture. In plumbing, closet flanges secure a water closet to the drain and help seal the connection.

Related: water closet, rough-in, wax ring
wax ring

A ring of pliable wax placed between a water closet outlet and the closet flange to form a watertight seal. It compresses when the fixture is set and prevents leakage at the floor connection.

Related: flange, water closet, trap seal
water closet

A toilet fixture that receives human waste and discharges it into the drainage system through a trap. It is set on a closet flange and connected with a water supply stop and flush valve or tank.

Related: flange, wax ring, drainage fixture unit
P-trap

A U-shaped fitting that holds a water seal to keep sewer gas out of the building while allowing waste to pass. It is required at most fixtures and must be vented to protect the seal.

Related: trap seal, trap arm, siphonage
shock absorber

A manufactured device installed in a water supply line to absorb pressure surges and reduce water hammer. It is an alternative to a simple air chamber and is often placed near quick-closing valves.

Related: water hammer, air chamber, velocity
meter

A device that measures and records the volume of water passing through a service line. It is typically installed at the property line or building entry and may include a backflow prevention component.

Related: water service, water main, backflow