NCCER Plumbing key terms
NCCER Plumbing · Get comfortable with the vocabulary.
- developed length
- Related: equivalent length, fixture unit, grade
The total measured distance a pipe runs along its centerline, including all horizontal and vertical segments and changes of direction, measured before fittings are installed. Used to estimate material quantities and to size pipe for pressure loss.
- equivalent length
- Related: developed length, pressure drop, friction loss
A method of expressing the pressure loss caused by fittings and valves as an added length of straight pipe of the same size. Added to developed length so friction loss through the whole run can be calculated.
- friction loss
- Related: pressure drop, equivalent length, velocity
The pressure lost as water moves through pipe, caused by the pipe wall and by turbulence at fittings. It increases with flow rate, pipe length, and roughness, and decreases with larger pipe diameter.
- pressure drop
- Related: friction loss, static head, residual pressure
The difference in pressure between two points in a piping system, usually caused by friction, elevation change, or a device in the line. Designers limit it so fixtures still receive adequate pressure.
- static head
- Related: pressure drop, residual pressure, water hammer
The pressure created by the weight of a column of water at a given height, equal to about 0.434 psi per foot of elevation. Used to account for height differences between a supply source and fixtures.
- residual pressure
- Related: static head, pressure drop, flow rate
The pressure remaining at a fixture or outlet while water is flowing. It must stay above the minimum required by code for the fixture to operate correctly and is checked during flow testing.
- flow rate
- Related: fixture unit, velocity, residual pressure
The volume of water passing a point in a piping system per unit of time, commonly expressed in gallons per minute. Used to size pipe, select pumps, and match supply to fixture demand.
- velocity
- Related: flow rate, water hammer, friction loss
The speed at which water travels through a pipe, usually stated in feet per second. Excessive velocity causes noise, erosion, and water hammer; codes and good practice set upper limits for supply and drainage piping.
- fixture unit
- Related: flow rate, drainage fixture unit, developed length
A unit of measure that assigns a relative load value to a plumbing fixture based on its probable flow demand. Fixture units are added together to size water supply and drainage systems for a building.
- drainage fixture unit
- Related: fixture unit, trap arm, soil stack
A value assigned to a fixture representing its probable discharge rate into a drainage system. Values are totaled to determine drain pipe size, trap size, and vent requirements for a building drain.
- water hammer
- Related: velocity, static head, air chamber
A loud banging or knocking in piping caused by a sudden stop in water flow, such as a quick-closing valve, producing a pressure surge. Controlled with air chambers, arrestors, or slower-closing valves.
- air chamber
- Related: water hammer, shock absorber, velocity
A vertical capped pipe or manufactured device connected near a fixture that traps air to absorb pressure surges when flow stops. It reduces water hammer and protects pipe and fittings from shock.
- grade
- Related: fall, developed length, trap arm
The slope of a drain pipe, expressed as fall per unit of length, such as one-quarter inch per foot. Proper grade lets waste flow by gravity while keeping liquid moving fast enough to carry solids.
- fall
- Related: grade, developed length, drainage fixture unit
The total vertical drop of a drain line over its run, calculated by multiplying the grade by the length. It must be checked so the pipe fits within available space and still drains properly.
- trap arm
- Related: trap seal, drainage fixture unit, grade
The section of drain pipe between a fixture trap and the point where it connects to a branch or stack. Its length and slope are limited by code so the trap seal is not siphoned out.
- trap seal
- Related: trap arm, vent stack, siphonage
The depth of water held in a fixture trap that blocks sewer gas from entering the building. Common seals are two to four inches deep and must be protected by proper venting.
- siphonage
- Related: trap seal, vent stack, trap arm
The pulling of water out of a fixture trap by pressure differences in the drainage or vent system, which breaks the seal and allows sewer gas into the building. Prevented by correct venting and trap arm length.
- vent stack
- Related: trap seal, siphonage, stack vent
A vertical pipe that provides air to a drainage system and allows sewer gases to escape above the roof. It protects trap seals by equalizing pressure in the drain piping.
- stack vent
- Related: vent stack, soil stack, trap seal
The extension of a soil or waste stack above the highest fixture connection, continuing through the roof to open air. It vents the stack and helps maintain atmospheric pressure in the drainage system.
- soil stack
- Related: waste stack, stack vent, drainage fixture unit
The main vertical drain pipe that carries sewage containing fecal matter from water closets and other fixtures down to the building drain. It must be sized and vented according to the fixtures it serves.
- waste stack
- Related: soil stack, vent stack, drainage fixture unit
A vertical drain pipe that carries liquid waste from fixtures other than water closets, such as sinks and lavatories. It connects to the building drain and is vented to protect trap seals.
- building drain
- Related: building sewer, soil stack, grade
The lowest horizontal portion of a drainage system that receives waste from the stacks and carries it to the building sewer. It is usually located just inside or under the building foundation.
- building sewer
- Related: building drain, grade, cleanout
The pipe that carries sewage from the building drain to the public sewer or private disposal system. It begins outside the building foundation and is typically owned and maintained by the property owner.
- cleanout
- Related: building drain, building sewer, trap arm
An accessible fitting with a removable cap installed on drainage piping so blockages can be cleared with a snake or rod. Codes require cleanouts at specified locations, such as the base of stacks and changes in direction.
- backflow
- Related: air gap, vacuum breaker, cross connection
The unwanted reversal of water flow in a piping system, which can contaminate the potable supply. Prevented with air gaps, vacuum breakers, and backflow prevention assemblies selected for the hazard level.
- cross connection
- Related: backflow, air gap, vacuum breaker
Any actual or potential link between a potable water system and a source of contamination or pollution. It must be eliminated or protected by an approved backflow prevention device.
- air gap
- Related: backflow, cross connection, vacuum breaker
The unobstructed vertical distance between a water supply outlet and the flood level rim of the fixture it serves. It is the most reliable form of backflow protection because no mechanical parts are involved.
- vacuum breaker
- Related: backflow, cross connection, air gap
A device that opens to admit air and break a vacuum in piping, preventing back-siphonage of contaminated water into the supply. Common types include atmospheric and pressure vacuum breakers.
- water service
- Related: water main, meter, backflow
The pipe and fittings that carry potable water from the water main or private source to the building. It includes the meter, valves, and the connection to the building's water distribution system.
- water main
- Related: water service, residual pressure, flow rate
A primary pipe in a public or private water distribution network that supplies individual water services. Its size and pressure determine the flow available to connected buildings.
- potable water
- Related: cross connection, backflow, water service
Water that is safe for human consumption and meets health-based quality standards. Plumbing codes require potable water for drinking, cooking, bathing, and other domestic uses.
- rough-in
- Related: trim, flange, cleanout
The phase of plumbing work in which pipes, fittings, and supports are installed before walls, floors, and fixtures are finished. Inspections typically occur after rough-in and before covering the work.
- trim
- Related: rough-in, flange, water closet
The finished, visible plumbing components installed after rough-in, such as faucets, spouts, escutcheons, and fixture trim plates. Trim work completes the system and is installed during final finishing.
- flange
- Related: water closet, rough-in, wax ring
A projecting rim or collar on a pipe or fitting used to make a connection or to support a fixture. In plumbing, closet flanges secure a water closet to the drain and help seal the connection.
- wax ring
- Related: flange, water closet, trap seal
A ring of pliable wax placed between a water closet outlet and the closet flange to form a watertight seal. It compresses when the fixture is set and prevents leakage at the floor connection.
- water closet
- Related: flange, wax ring, drainage fixture unit
A toilet fixture that receives human waste and discharges it into the drainage system through a trap. It is set on a closet flange and connected with a water supply stop and flush valve or tank.
- P-trap
- Related: trap seal, trap arm, siphonage
A U-shaped fitting that holds a water seal to keep sewer gas out of the building while allowing waste to pass. It is required at most fixtures and must be vented to protect the seal.
- shock absorber
- Related: water hammer, air chamber, velocity
A manufactured device installed in a water supply line to absorb pressure surges and reduce water hammer. It is an alternative to a simple air chamber and is often placed near quick-closing valves.
- meter
- Related: water service, water main, backflow
A device that measures and records the volume of water passing through a service line. It is typically installed at the property line or building entry and may include a backflow prevention component.