33 cards. Read the term and the definition here. The deck at the top of this page is optional.

Illuminance
Luminous flux incident on a unit area of surface, measured in lux (lm/m²) or footcandles (lm/ft²). It is the quantity most codes and IES recommendations specify for tasks.
Luminance
Luminous intensity emitted or reflected per unit projected area, in cd/m². It corresponds to perceived brightness and is the quantity that produces glare and visibility contrast.
Inverse-square law
Illuminance from a point source equals intensity divided by the square of the distance, E = I/d². Doubling the distance reduces illuminance to one quarter of its prior value.
Cosine law
Illuminance on a tilted surface equals I·cosθ/d², where θ is the angle between the incoming light and the surface normal. Off-axis light delivers proportionally less illuminance.
Luminous efficacy
Ratio of luminous flux produced to electrical power consumed, in lumens per watt. It allows comparison of source efficiency, though system efficacy should include driver and ballast losses.
Correlated color temperature
The absolute temperature of a blackbody whose color appearance most closely matches the lamp, in kelvin. Warm sources are below about 3300 K; cool sources exceed 5300 K.
Color rendering index
A 0–100 scale comparing a source's rendering of test color samples with a reference source. Higher values indicate more faithful color appearance; R9 specifically rates saturated red.
Maintenance factor
A multiplier below one accounting for lumen depreciation, dirt on luminaires and surfaces, and lamp failures. Design illuminance equals initial illuminance multiplied by this factor.
Coefficient of utilization
The fraction of lamp lumens that reaches the work plane, derived from luminaire photometrics, room cavity ratio, and surface reflectances. Higher values mean more efficient delivery.
Room cavity ratio
A dimensionless index of room proportions used with photometric tables: RCR = 5·h·(L+W)/(L·W), where h is cavity height. Larger values indicate taller or narrower rooms.
Lumen method
The average-illuminance design formula: number of luminaires = (target illuminance × area) ÷ (lumens per lamp × coefficient of utilization × maintenance factor). It assumes uniform layout.
Spacing-to-mounting-height ratio
The maximum luminaire spacing divided by mounting height above the work plane that still yields acceptable uniformity. Exceeding the rated value causes scalloping and dark bands.
Lighting power density
Connected lighting watts divided by floor area, in W/m² or W/ft². Energy codes set maximum allowances by space type; controls and reduced wattage help comply.
LENI
Lighting energy numeric indicator, total annual lighting energy divided by floor area in kWh/m²/yr. Unlike power density, it reflects operating hours and control savings.
L70 rating
The operating hours at which a population of LED luminaires is projected to reach 70 percent of initial lumen output. It is a statistical depreciation rating, not a failure guarantee.
Ballast factor
The ratio of a lamp's light output on a given ballast to its output on the reference ballast. It scales both lumens and input wattage in fluorescent calculations.
UGR
Unified glare rating, a scale for discomfort glare from interior luminaires. Lower values mean less glare; office tasks commonly specify limits such as 19 or lower.
BUG rating
Backlight, uplight, and glare ratings that summarize an outdoor luminaire's light distribution. They are used to control light trespass, skyglow, and glare at property lines.
Occupancy sensor
A control that turns lighting on when presence is detected and off after a set delay. Vacancy sensors instead require manual-on operation, which typically saves more energy.
Daylight harvesting
Automatic dimming or stepped switching of electric lighting in response to available daylight, using a photosensor. Proper calibration prevents hunting and nuisance switching.
Veiling reflection
Reflected glare that reduces task contrast, often seen on glossy paper or screens. It is addressed by relocating or shielding the source rather than raising illuminance.
Cylindrical illuminance
Average illuminance on the vertical surface of a small cylinder at a point. It indicates how well faces and vertical surfaces are lit in a space.
Flicker index
A measure of light output modulation above the average, ranging from 0 to 1. Higher values indicate more perceptible flicker and potential stroboscopic effects.
IES photometric file
A digital file describing a luminaire's intensity distribution, lumen output, and spacing criteria. Calculations are only valid if the file matches the installed luminaire and optic.
Footcandle
One lumen of luminous flux incident on one square foot of surface, equal to about 10.76 lux. It is still used in many US lighting recommendations and codes.
Lux
One lumen of luminous flux incident on one square meter of surface. It is the SI unit of illuminance and the basis for most metric lighting design targets.
Simple payback
Installed retrofit cost divided by annual energy and maintenance savings. It is a quick screening metric that ignores energy escalation and equipment life beyond the payback period.
Egress illumination
Minimum lighting along the path of egress, commonly about 10.8 lux (1 fc) at floor level, maintained for 90 minutes on emergency power. Exit signs must also be illuminated.
Commissioning
Verification that installed lighting and controls meet design intent: measured illuminance, calibrated sensors, confirmed sequences, and documented settings handed to the owner.
SDCM
Standard deviation of color matching, a measure of color consistency between lamps. A small value such as 3–5 means adjacent luminaires appear nearly identical in tint.
Task-ambient lighting
A strategy using modest general ambient light plus localized task lighting at work surfaces. It reduces total connected load while maintaining adequate task illuminance and contrast.
Light trespass
Spill light falling beyond the property boundary or into unwanted areas. It is limited by full cut-off optics, aiming, shielding, and backlight ratings on outdoor luminaires.
Luminous flux
The total light output of a source in all directions, measured in lumens. Lamp and luminaire lumen ratings are the starting point for any illuminance calculation.