Luminous flux

The total amount of visible light a lamp or luminaire emits in all directions, measured in lumens. It describes output quantity without regard to where the light goes.

Related: Luminous intensity, Illuminance
Luminous intensity

The amount of light emitted by a source in a particular direction per solid angle, measured in candelas. It describes directional strength and underlies photometric distribution curves.

Related: Luminous flux, Candela, Photometric report
Illuminance

The density of luminous flux arriving on a surface, measured in lux or footcandles. It is the quantity most lighting recommendations specify for tasks and circulation areas.

Related: Lux, Footcandle, Luminance
Luminance

The light reflected or emitted from a surface in a given direction per unit area, measured in candelas per square meter. It corresponds to brightness as the eye perceives it.

Related: Illuminance, Reflectance, Glare
Lux

The metric unit of illuminance, equal to one lumen per square meter. Metric lighting recommendations and most international standards express design targets in lux.

Related: Illuminance, Footcandle
Footcandle

The customary unit of illuminance, equal to one lumen per square foot. One footcandle equals about 10.76 lux, a conversion candidates should be able to apply quickly.

Related: Lux, Illuminance
Candela

The SI base unit of luminous intensity, describing light emitted in a specific direction. Luminaire photometric data are typically reported in candelas at many angles.

Related: Luminous intensity, Photometric report
Lumen depreciation

The gradual loss of light output a lamp or LED module experiences over operating hours. It is one factor in the light loss factor used to size initial versus maintained illuminance.

Related: Light loss factor, Lumen maintenance, L70
Lumen maintenance

The ability of a light source to retain its output over time, often stated as the percentage of initial lumens remaining at a given operating hour. Good maintenance reduces overdesign.

Related: Lumen depreciation, L70
L70

The operating hours at which an LED source's light output has declined to 70 percent of its initial value. It is a common lifetime rating for LED products.

Related: Lumen maintenance, Lumen depreciation
Light loss factor

A multiplier applied to initial illuminance to predict maintained levels, accounting for dirt on luminaires and surfaces, lamp aging, and burnout. It keeps designs realistic over the maintenance cycle.

Related: Lumen depreciation, Maintenance category, Coefficient of utilization
Coefficient of utilization

The fraction of lumens leaving a luminaire that reach the work plane, given room proportions and surface reflectances. It is central to the lumen method of average illuminance calculation.

Related: Lumen method, Room cavity ratio, Light loss factor
Lumen method

A calculation technique that divides total delivered lamp lumens by the area served to estimate average maintained illuminance. It assumes uniform layout and is not suited to accent or task lighting.

Related: Coefficient of utilization, Room cavity ratio, Light loss factor
Room cavity ratio

A dimensionless index describing a room's proportions, derived from its length, width, and mounting height above the work plane. It is used to look up coefficient of utilization values.

Related: Coefficient of utilization, Lumen method
Photometric report

A test document reporting a luminaire's intensity distribution, efficacy, and often glare and color data. It is the basis for lighting calculations and product comparison.

Related: Luminous intensity, Zonal lumen density, Efficacy
Efficacy

The ratio of light output to power consumed, expressed in lumens per watt. Higher efficacy means more light for the same energy, though color and distribution quality also matter.

Related: Luminous flux, Power density
Correlated color temperature

A number in kelvin describing whether white light appears warm, neutral, or cool, based on the blackbody radiator it resembles. It does not by itself describe color fidelity.

Related: Color rendering index, Chromaticity
Color rendering index

A scale, usually to 100, rating how faithfully a light source shows object colors compared with a reference source. Higher values generally indicate more natural appearance.

Related: Correlated color temperature, Chromaticity
Chromaticity

The color quality of light independent of its brightness, often plotted on a diagram to compare sources. It underpins specifications for color temperature and tint consistency.

Related: Correlated color temperature, Color rendering index
Glare

Visual discomfort or loss of visibility caused by luminance in the field of view that is much brighter than its surroundings. It is managed through shielding, brightness limits, and placement.

Related: Disability glare, Discomfort glare, Unified glare rating
Disability glare

Glare that physically reduces the ability to see detail, for example by scattering light within the eye. It impairs task performance rather than merely causing annoyance.

Related: Glare, Discomfort glare, Veiling reflection
Discomfort glare

Glare that produces annoyance or a sensation of visual discomfort without necessarily reducing task visibility. It is often predicted with rating systems based on source luminance and position.

Related: Glare, Unified glare rating, Disability glare
Unified glare rating

A method that computes a glare index from luminaire luminance, background luminance, and viewing geometry. Lower values indicate less glare, and limits are often set by application.

Related: Discomfort glare, Glare, Luminance
Veiling reflection

Reflected glare that reduces contrast on a task surface, such as a screen or glossy paper, by superimposing a bright image. It is controlled by geometry, matte finishes, and diffuse lighting.

Related: Disability glare, Glare, Reflectance
Reflectance

The proportion of light striking a surface that is reflected rather than absorbed or transmitted. Surface reflectances strongly affect how much interreflected light reaches the work plane.

Related: Luminance, Coefficient of utilization
Zonal lumen density

The share of a luminaire's total lumens emitted within defined angular zones, such as downward cones. It helps evaluate distribution and suitability for a space.

Related: Photometric report, Luminous intensity
Power density

Installed lighting power divided by floor area, usually in watts per square meter or square foot. It is a common energy code metric and is compared against allowed limits.

Related: Efficacy, Lighting power allowance
Lighting power allowance

The maximum lighting power permitted for a space or building under an energy code, often calculated by area method or space-by-space method. It drives design choices toward efficient equipment and controls.

Related: Power density, Lighting controls
Lighting controls

Devices and strategies that adjust light output or operation, including dimming, occupancy sensing, daylight harvesting, and scheduling. They reduce energy use and support visual needs over time.

Related: Daylight harvesting, Occupancy sensor, Lighting power allowance
Daylight harvesting

Automatically dimming or switching electric light in response to available daylight, typically using photosensors. It saves energy while preserving required illuminance.

Related: Lighting controls, Illuminance
Occupancy sensor

A control device that detects whether a space is occupied and switches or dims lighting accordingly. It is distinct from a vacancy sensor, which requires manual turn-on.

Related: Lighting controls, Daylight harvesting
Illuminance uniformity

How evenly illuminance is distributed across an area, commonly expressed as a ratio of minimum to average or maximum to minimum. Poor uniformity creates bright and dim patches that hinder tasks.

Related: Illuminance, Luminance
Task-ambient lighting

A design approach combining lower general ambient light with higher localized light where tasks occur. It can improve efficiency and give occupants control over their own work area.

Related: Illuminance, Lighting controls
Luminaire

A complete lighting unit comprising a lamp or LED module with the parts that distribute light, position it, protect it, and connect it to power. Its optics and shielding shape the delivered light.

Related: Luminous intensity, Photometric report, Baffle
Baffle

A shielding element, often a series of vanes, that blocks direct view of a lamp or LED at certain angles. It reduces glare while allowing controlled light distribution.

Related: Glare, Luminaire
Color shift

A change in a light source's chromaticity over time or across units of the same product. It matters in installations where consistent appearance between fixtures is expected.

Related: Chromaticity, Correlated color temperature
Maintenance category

A classification of how dirty an environment is expected to be, used to select light loss factors for cleaning schedules. Clean offices and dirty industrial spaces fall in different categories.

Related: Light loss factor, Lumen depreciation