32 cards. Read the term and the definition here. The deck at the top of this page is optional.

PEL for asbestos
OSHA permissible exposure limit is 0.1 fibers per cubic centimeter as an 8-hour time-weighted average, measured by phase contrast microscopy.
Excursion limit
The short-term asbestos exposure limit of 1.0 fiber per cubic centimeter averaged over any 30-minute sampling period during a shift.
Regulated area sign
Warning sign required at asbestos work areas reading DANGER, ASBESTOS, AUTHORIZED PERSONNEL ONLY, with a description of the required protective equipment.
Decontamination unit sequence
A three-stage unit: dirty room for removing contaminated clothing, shower room for washing, and clean room for dressing in street clothes.
Wet methods
Technique of wetting asbestos-containing material with amended water before and during disturbance to suppress fiber release into the air.
Assigned protection factor
The expected workplace level of respiratory protection for a properly fitted respirator class; half-mask APR is 10 and full-face PAPR is 1,000.
Negative pressure requirement
Containments must be held at least 0.02 inches of water column below adjacent areas, verified with a manometer and recorded regularly.
Aggressive air sampling
Clearance sampling performed after forcing air movement with a leaf blower or fan to suspend settled fibers before collecting samples inside the enclosure.
Clearance criterion
Final clearance passes when all inside air samples are below 0.01 fibers per cubic centimeter by PCM, or the stricter limit in the specification.
Critical barriers
Seals placed over HVAC openings, doors, windows, and other penetrations to isolate the work area and prevent fiber migration.
Waste manifest
Shipping document identifying the generator, quantity, and destination of asbestos waste, retained as a record of proper disposal.
Medical record retention
OSHA requires employers to keep employee medical records for the duration of employment plus 30 years after separation.
Homogeneous area
Material that appears uniform in color and texture and was installed at the same time, sampled as a single unit.
PLM analysis
Polarized light microscopy per EPA 600/R-93/116 identifies asbestos type and estimates percentage; point counting is used near 1 percent.
Friable material
Asbestos-containing material that can be crumbled, pulverized, or reduced to powder by hand pressure when dry.
Thermal system insulation
Surfacing material applied to pipes, boilers, tanks, and ducts to control temperature; a common category of asbestos-containing material.
Sampling layers
A coring tool must penetrate all layers of layered material, and each distinct layer is analyzed separately for asbestos content.
Inspection report contents
Documents homogeneous areas, sample locations, quantities, material condition, analytical method, and a floor plan of the building.
Management plan update
AHERA management plans must be updated every 3 years following reinspection, and periodic surveillance occurs every 6 months.
Response action hierarchy
Preferred options ranked from removal through enclosure, encapsulation, repair, operations and maintenance, to no action, chosen by hazard.
Hazard assessment
Combines material condition, friability, accessibility, and likelihood of disturbance to assign a priority ranking for response.
O&M program
Operations and maintenance plan for friable asbestos left in place, including cleaning, training, and periodic surveillance every 6 months.
Enclosure versus encapsulation
Enclosure places a rigid barrier over the material; encapsulation seals the surface with a coating. Neither removes the hazard.
Reinspection interval
A certified inspector must reinspect asbestos-containing material every 3 years so the management planner can revise the plan.
Negative air machine sizing
Machines are sized to provide roughly one air change every 15 minutes, or enough capacity to hold the containment under negative pressure.
Design specification contents
Scope of work, containment layout, decontamination plan, waste route, air monitoring method, and clearance criteria prepared by the designer.
HVAC shutdown
Building heating and cooling systems serving the work area must be isolated and locked out to prevent fiber distribution through ducts.
TEM versus PCM
PCM counts all fibers and is used for routine monitoring; TEM identifies asbestos fibers specifically and is used where specifications require it.
Project monitor role
Independent observer who verifies contractor compliance with the specification, documents conditions, and reports deviations to owner and contractor.
Stop-work condition
A sustained loss of negative pressure, breached containment, or visible debris release that requires halting work until corrected.
Daily monitoring log
Record of dates, times, personnel, manometer readings, air sample results, deviations observed, and corrective actions taken on site.
Final monitoring report
Compilation of inspection findings, air monitoring data, clearance results, and a compliance statement delivered to the building owner.