- Ampacity
- Related: Conductor Bundling Adjustment, Ambient Temperature Correction Factor
The maximum continuous current, in amperes, that a conductor can carry under the conditions of use without exceeding its temperature rating. It depends on conductor material, size, insulation type, and ambient conditions.
- Conductor Bundling Adjustment
- Related: Ampacity, Raceway
A percentage reduction applied to conductor ampacity when more than three current-carrying conductors share a raceway or cable without maintained spacing, because mutual heating reduces the ability to dissipate heat.
- Ambient Temperature Correction Factor
- Related: Ampacity, Conductor Bundling Adjustment
A multiplier applied to a conductor's base ampacity to account for surrounding air temperatures above the value assumed by the insulation rating, since hotter surroundings reduce heat dissipation.
- Continuous Load
- Related: Overcurrent Protective Device, Noncontinuous Load
A load expected to operate at maximum current for three hours or more. Conductors and overcurrent devices serving continuous loads must be sized at no less than 125 percent of the load.
- Noncontinuous Load
- Related: Continuous Load
A load that operates at maximum current for less than three hours in any given period. It is not subject to the 125 percent sizing adder that applies to continuous loads.
- Overcurrent Protective Device
- Related: Continuous Load, Ground-Fault Circuit Interrupter, Series Rated System
A device such as a circuit breaker or fuse that automatically opens a circuit when current exceeds a predetermined value, protecting conductors and equipment from overheating and fault damage.
- Ground-Fault Circuit Interrupter
- Related: Overcurrent Protective Device, Equipment Grounding Conductor
A device that de-energizes a circuit within a set time when current to ground exceeds a threshold well below the level needed to trip a standard breaker, protecting people from shock.
- Equipment Grounding Conductor
- Related: Grounding Electrode System, Ground-Fault Circuit Interrupter, Bonding Jumper
The conductor that connects the non-current-carrying metal parts of equipment to the grounding electrode system, providing a low-impedance fault path that lets overcurrent devices clear faults.
- Grounding Electrode System
- Related: Equipment Grounding Conductor, Bonding Jumper
The set of grounding electrodes and their connecting conductors that establishes a direct, permanent connection to earth, anchoring the electrical system's reference to ground potential.
- Bonding Jumper
- Related: Equipment Grounding Conductor, Grounding Electrode System
A conductor, screw, or strap that ensures electrical continuity between metal parts that must be electrically connected, equalizing potential and providing a path for fault current.
- Raceway
- Related: Conductor Bundling Adjustment, Conduit Fill, Wireway
An enclosed channel of metal or nonmetallic material designed expressly for holding wires, cables, or busbars, with additional functions permitted by the code depending on its type.
- Conduit Fill
- Related: Raceway, Wireway
The percentage of a conduit's internal cross-sectional area occupied by conductors. Limits vary by conductor count and conduit type to allow pulling and prevent insulation damage from heat.
- Wireway
- Related: Raceway, Conduit Fill
A sheet-metal or nonmetallic trough with a removable cover, used to house and support conductors and cables, often where multiple circuits run in accessible locations.
- Box Fill
- Related: Raceway, Wireway
The required minimum volume of an outlet, junction, or device box based on the number and size of conductors, devices, and fittings it contains, preventing overcrowding and insulation damage.
- Service Point
- Related: Service Entrance Conductors, Feeder
The point where the serving utility's conductors connect to the premises wiring, marking the boundary between utility-owned and customer-owned equipment for code purposes.
- Service Entrance Conductors
- Related: Service Point, Service Equipment
The conductors that carry power from the service point to the service equipment, including both overhead and underground service conductors on the customer side of the demarcation.
- Service Equipment
- Related: Service Entrance Conductors, Feeder
The necessary equipment, usually a switchboard or panelboard with breakers, that controls and cuts off power to a building's wiring and contains the service disconnecting means.
- Feeder
- Related: Branch Circuit, Service Equipment
All circuit conductors between the service equipment, source of a separately derived system, or other supply source and the final branch-circuit overcurrent device.
- Branch Circuit
- Related: Feeder, Overcurrent Protective Device
The circuit conductors between the final overcurrent device protecting the circuit and the outlets or loads it serves, forming the last segment of the distribution system.
- Demand Factor
- Related: Load Calculation, Feeder
The ratio of the maximum demand on a system to the total connected load, used to size service and feeder equipment realistically because not all loads operate at once.
- Load Calculation
- Related: Demand Factor, Feeder
A structured method of summing lighting, receptacle, appliance, motor, and other loads, applying demand factors, to determine the minimum capacity of service and feeder conductors and equipment.
- Working Clearance
- Related: Dedicated Equipment Space, Arc Flash Hazard
The required clear floor space and headroom in front of electrical equipment, kept free of obstructions, allowing safe inspection, servicing, and maintenance of energized parts.
- Dedicated Equipment Space
- Related: Working Clearance
The area above and in front of switchboards, panelboards, and similar equipment reserved exclusively for electrical wiring and equipment, excluding piping and ducts unrelated to the electrical installation.
- Arc Flash Hazard
- Related: Working Clearance, Disconnecting Means
A dangerous condition in which an electric arc releases intense heat, light, and pressure, requiring equipment labeling and safe work practices for personnel who service energized electrical systems.
- Disconnecting Means
- Related: Service Equipment, Working Clearance
A device or group of devices that can disconnect the conductors of a circuit from their supply source, allowing equipment to be isolated for servicing and maintenance.
- Series Rated System
- Related: Overcurrent Protective Device, Short-Circuit Current Rating
A combination of overcurrent devices where a downstream breaker relies on an upstream device to interrupt high available fault current, typically marked and tested as a listed combination.
- Short-Circuit Current Rating
- Related: Series Rated System, Overcurrent Protective Device
The maximum prospective fault current a piece of equipment can safely withstand or interrupt without damage, used to verify equipment is not applied where available fault current is higher.
- Classified Location
- Related: Intrinsically Safe Circuit, Explosionproof Equipment
An area where fire or explosion hazards may exist due to flammable gases, vapors, dusts, or fibers, requiring special wiring methods and equipment approved for the specific hazard class and division or zone.
- Intrinsically Safe Circuit
- Related: Classified Location, Explosionproof Equipment
A circuit designed so that any spark or thermal effect produced under normal or fault conditions cannot ignite a flammable atmosphere, typically by limiting voltage and current to low levels.
- Explosionproof Equipment
- Related: Classified Location, Intrinsically Safe Circuit
Enclosures designed to contain an internal explosion and prevent ignition of surrounding flammable atmosphere, used in certain classified locations such as Class I hazardous areas.
- Health Care Facility Essential Electrical System
- Related: Standby Power System, Receptacle Critical Care
A system of circuits and equipment arranged to supply power to critical patient care areas, life safety, and equipment branches so essential functions continue during a utility outage.
- Standby Power System
- Related: Health Care Facility Essential Electrical System, Transfer Switch
An alternate source of electric power, such as a generator, that supplies designated loads when the normal supply fails, typically required for life safety and critical operations.
- Transfer Switch
- Related: Standby Power System
A device that switches load connections from the normal power source to an alternate source and back, preventing inadvertent interconnection of the two supplies.
- Fire Pump Circuit
- Related: Standby Power System, Overcurrent Protective Device
A dedicated circuit supplying fire pump equipment, required to remain energized during a fire and be protected and routed so that failure of other circuits does not disable the pump.
- Class 2 Circuit
- Related: Class 3 Circuit, Communication Circuit
A circuit with limited power and voltage, as defined by its supply source, that poses low fire and shock risk and may use lighter wiring methods than power circuits.
- Class 3 Circuit
- Related: Class 2 Circuit, Communication Circuit
A circuit with power and voltage limits above Class 2 but still restricted, used for signaling and control, allowing different wiring methods than line-voltage power circuits.
- Communication Circuit
- Related: Class 2 Circuit, Raceway
A circuit that carries signals for telephone, data, cable television, or similar communications, subject to separate article requirements and permitted to share certain raceways under conditions.
- Plenum
- Related: Communication Circuit, Raceway
A space used for air handling, such as above a suspended ceiling, where cable routing and materials are restricted because smoke from burning materials would spread through the building's air system.
- Voltage Drop
- Related: Ampacity, Feeder
The loss of voltage along conductors due to their resistance and reactance, which increases with current and distance and can impair equipment performance if not limited by proper conductor sizing.