NRCA Tile Installer study materials
NRCA Tile Installer study resources

NRCA Tile Installer cheat sheet

NRCA Tile Installer · Keep the key ideas within reach.

Quick reference

Safety, Fall Protection, and Jobsites

  • OSHA fall protection trigger for steep-slope roofs (slope greater than 4:12) is 6 ft; conventional fall protection must be in place before work begins.

  • Warning line plus safety monitoring system is permitted only for low-slope roofs (4:12 or less) and only when no other fall protection is feasible.

  • Guardrail top edge height: 42 in. plus or minus 3 in., with a midrail at approximately half height and a 4 in. minimum toe board.

  • Personal fall arrest system: full-body harness, anchor rated 5,000 lb per worker, and maximum free-fall distance of 6 ft; keep total fall distance clear of lower levels.

  • Ladder extension above the eave or landing: 3 ft minimum; ladder setup angle 4:1 (1 ft out per 4 ft of height).

  • Roof brackets and roof jacks must be nailed into structural members, not sheathing alone; space per manufacturer and never exceed the rated load.

  • Lanyard attachment point must be at or above shoulder level (D-ring in back) to limit free fall and swing-fall hazard.

  • Hot-work and open-flame rules: keep a fire extinguisher within reach, clear combustibles, and maintain a fire watch during and after torch or kettle work.

  • Material hoisting: never exceed the ladder or scaffold load rating; keep the ground area below barricaded during raising and lowering.

Quick reference

Roof Deck, Underlayment, and Substrate Preparation

  • Minimum roof slope for tile without special detailing is 4:12; slopes from 2.5:12 to 4:12 require a doubled underlayment or manufacturer-approved low-slope assembly.

  • Deck deflection limit for most tile assemblies: L/360 for the total load (dead plus live) unless the manufacturer requires stiffer.

  • Solid sheathing for tile: minimum 15/32 in. plywood or 7/16 in. OSB, fastened with 8d common nails at 6 in. on center at edges and 12 in. in the field.

  • Sheathing gaps: 1/8 in. between panel edges for expansion; stagger end joints and support all edges on framing.

  • Underlayment laps: 6 in. on sides and 12 in. at ends for steep-slope; laps must shed water down-slope, upper sheet over lower.

  • Ice dam protection (where required): self-adhering membrane from the eave edge to at least 24 in. inside the warm wall line.

  • Eave and rake overhangs must be sheathed and underlayment carried over the fascia edge with a metal drip edge.

  • Ventilation: net free vent area of 1/150 of the attic floor area when balanced (1/300 with balanced intake and exhaust and a vapor retarder).

  • Fastener penetration through sheathing: at least 3/8 in. beyond the underside of the panel or per code; never overdrive and crush the panel.

Quick reference

Tile Materials, Types, and Standards

  • ASTM C1167 covers clay roof tile; Grade 1 is the highest grade, with freeze-thaw durability tested per the standard.

  • ASTM C406 covers concrete roof tile; Grade A is the highest grade.

  • ASTM C836 is the specification for liquid-applied waterproofing membranes used in tile roof assemblies.

  • ASTM A653 specifies hot-dip galvanized steel; G90 coating is a common minimum for roof flashings.

  • S-profile tile is a high-profile interlocking tile; flat or low-profile tile requires a steeper minimum slope or a built-up underlayment system.

  • Tile weight reference: concrete tile typically 8-12 lb per sq ft; clay tile 6-10 lb per sq ft; verify the actual product data for structural design.

  • Tile should be tested for water absorption and freeze-thaw resistance; absorption over about 6% raises frost damage risk in cold climates.

  • A square of roofing equals 100 sq ft; tile coverage per square varies with exposure, so order by the manufacturer's pieces per square.

  • Tile fasteners: corrosion-resistant nails or screws; 11-gauge or heavier, long enough to penetrate sheathing at least 3/4 in.

Quick reference

Flashings, Penetrations, and Waterproofing Details

  • Step flashing: one piece per course of tile, minimum 4 in. wide by 4 in. high, lapped 2 in. and set under the tile above and over the tile below.

  • Chimney flashing sequence: apron at the bottom, step flashing on the sides, and a cricket (saddle) on the up-slope side when the chimney width exceeds 30 in.

  • Valley flashing: metal valley minimum 24 in. wide (12 in. each side) for open valleys; lap each course so water flows over the lower piece.

  • Pipe and vent penetrations: use a lead or neoprene boot or a proprietary flashing collar, with the upper flange tucked under the tile above.

  • Drip edge: required at eaves and rakes; metal should extend at least 1/4 in. below the sheathing edge and behind the underlayment at the eave.

  • Kick-out flashing at sidewalls: diverts water away from the wall and into the gutter; a missing kick-out is a common leak and rot source.

  • Headwall and sidewall flashing: use a two-piece counterflashing system so the upper piece is removable for maintenance.

  • Waterproofing at low-slope transitions (2.5:12 to 4:12): use a self-adhering membrane at least 12 in. on each side of the transition and lap per the manufacturer.

Quick reference

Tile Layout, Attachment, and Fastening

  • Tile layout: establish a true vertical centerline and lay tile from the center out, or from a full-tile edge, so cut tiles fall at the rakes.

  • Course exposure: measure the tile length minus headlap; the manufacturer's exposure determines pieces per square and total order quantity.

  • Fastening rule: fasten every tile in high-wind zones (typically 90 mph basic wind speed or greater) and at hips, ridges, and perimeter; otherwise follow the manufacturer's schedule.

  • Nail placement: drive fasteners through the nail holes so the tile hangs; do not overdrive, and leave the head slightly above the tile surface.

  • Nail penetration into sheathing: minimum 3/4 in. for nails; screws must engage the framing or sheathing per the manufacturer's listing.

  • Wind uplift design: use the code's wind speed map and the tile manufacturer's uplift rating; add fasteners at corners and edges where uplift is highest.

  • Tile spacing: maintain the manufacturer's recommended side lap and head lap; tight butting can crack tiles and block drainage.

  • Cut tiles at rakes and hips should be fastened with two fasteners and supported fully by the underlayment and flashing.

Quick reference

Eaves, Rakes, Hips, Ridges, and Valleys

  • Eave closure: use a bird stop or eave closure to block wind-driven rain and prevent birds from entering the tile profile.

  • Rake tile: set rake tiles over a rake trim or flashing, fastened to the barge rafter or fascia, with the underlayment carried over the edge.

  • Hip and ridge: fasten hip and ridge tile with two fasteners per piece and use a hip/ridge batten or mortar bed per the manufacturer.

  • Hip and ridge ventilation: ridge vent area should balance with soffit intake; net free area per code (1/150 or 1/300 rule).

  • Valley types: open metal valley (visible metal) vs. closed-cut valley (tile from one slope crosses the valley and is cut along the other slope).

  • Open valley width: typically 3-4 in. of exposed metal at the valley center, with tile cut back at least 2 in. from the centerline on each side.

  • Valley underlayment: install a minimum 24 in. wide membrane or metal valley under the tile, extending at least 12 in. up each slope.

  • Ridge cap fastening in high-wind zones: use screws or ring-shank nails and consider a mechanical ridge vent system rated for the design wind speed.

  • Hip and ridge mortar: use a Type N or S mortar with proper mixing; keep weep holes clear so moisture can escape.

Quick reference

Steep-Slope and Low-Slope Tile Applications

  • Steep-slope tile (4:12 and steeper): use battens or a counter-batten system where required by the manufacturer to create a drainage plane.

  • Low-slope tile (2.5:12 to 4:12): use a double-layer underlayment or a proprietary waterproofing membrane assembly and follow the manufacturer's low-slope detail.

  • Slopes below 2.5:12 generally cannot use standard tile without a special engineered assembly; verify the manufacturer's written approval.

  • Tile over battens: battens must be fastened into framing or sheathing per the manufacturer; do not rely on sheathing alone for battens.

  • Cold-climate detail: ice dam membrane at the eave plus a drainage plane above the underlayment reduces ice-dam back-up leaks.

  • High-wind application: use the manufacturer's high-wind fastening schedule and consider foam or mechanical closures at eaves and rakes.

  • Tile at transitions to low-slope roofs: use a minimum 12 in. vertical or horizontal transition membrane and a cricket or diverter where water ponds.

  • Ventilation and condensation: a ventilated air space above the underlayment helps dry the assembly in humid climates; follow the manufacturer's vent detail.

Quick reference

Repair, Restoration, and Maintenance

  • Broken tile replacement: lift the tile above, slide the new tile into place, and fasten through the existing nail holes; never nail through the tile below.

  • Cracked tile repair: replace rather than seal when the crack crosses the tile body; sealant is a temporary fix only for hairline cracks.

  • Leak diagnosis: check flashings, valleys, and penetrations first; these cause more leaks than tile field failures.

  • Moss and algae: use a low-pressure wash and a manufacturer-approved cleaner; never use a high-pressure washer that can strip the tile surface.

  • Mortar repair at hips and ridges: remove loose mortar, clean the joint, and repack with a compatible mortar; keep weep holes open.

  • Fastener corrosion: replace corroded fasteners with hot-dip galvanized or stainless steel; corrosion often indicates a long-term moisture problem.

  • Walking on tile: step on the headlap area over the batten or framing, not on the unsupported tile center, to avoid cracking.

  • Maintenance schedule: inspect after major storms and annually; clear debris from valleys and gutters to prevent water back-up.

Quick reference

Print Reading, Estimating, and Code Compliance

  • Roof plan reading: identify slope indicators, ridge lines, valleys, and penetration symbols; slope is expressed as rise:run (e.g., 6:12).

  • Slope factor formula: slope factor = sqrt(1 + (rise/run)^2); multiply the plan area by the slope factor to get the actual roof area.

  • Roof area estimation: plan area x slope factor = actual area; add 10-15% waste for hips, valleys, and cuts.

  • Tile quantity: pieces per square from the manufacturer's exposure data; order by the square, then convert to pieces and add waste.

  • Underlayment quantity: one roll typically covers 4 squares (400 sq ft) for 36 in. wide material; account for laps.

  • Code compliance: IRC Chapter 9 covers roof assemblies; check the local jurisdiction for amendments and wind/seismic requirements.

  • Wind design: use the code wind speed map and the manufacturer's uplift rating; fastening schedules must match the design wind speed.

  • Inspection checklist: verify sheathing thickness and fastening, underlayment laps, flashing heights, and tile fastening before sign-off.

  • Bid documents: confirm the scope includes tear-off, deck repair allowance, flashing replacement, and disposal; hidden conditions are common in re-roofing.