NRCA Tile Installer study materials
NRCA Tile Installer study resources

NRCA Tile Installer flashcards

NRCA Tile Installer · Build recall with a focused review session.

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Fall protection trigger height
OSHA requires conventional fall protection for work on steep-slope roofs at 6 ft or more above a lower level, and the system must be in place before work begins.
Guardrail height
A guardrail top edge must be 42 in. plus or minus 3 in. above the walking surface, with a midrail at about half height and a toe board at the bottom.
Personal fall arrest anchor
A personal fall arrest system requires a full-body harness and an anchor rated at 5,000 lb per worker, with a maximum free fall of 6 ft.
Ladder extension above eave
A ladder used for roof access must extend at least 3 ft above the eave or landing point, and be set at a 4:1 angle.
Roof jack fastening
Roof brackets and roof jacks must be fastened into structural framing members, not sheathing alone, and must not exceed their rated load.
Minimum slope for tile
Standard tile assemblies require a minimum roof slope of 4:12; slopes from 2.5:12 to 4:12 need a doubled underlayment or approved low-slope assembly.
Deck deflection limit
Most tile roof assemblies require the deck to limit deflection to L/360 under total load, unless the tile manufacturer requires a stiffer deck.
Sheathing thickness for tile
Solid sheathing for tile roofs is typically at least 15/32 in. plywood or 7/16 in. OSB, fastened with 8d common nails at 6 in. edges and 12 in. field.
Underlayment lap rules
Steep-slope underlayment laps at least 6 in. on sides and 12 in. at ends, with upper sheets lapped over lower sheets so water sheds down-slope.
Ice dam membrane extent
Where ice dam protection is required, self-adhering membrane runs from the eave edge to at least 24 in. inside the warm wall line.
ASTM C1167
ASTM C1167 is the standard specification for clay roof tile, covering Grade 1 through Grade 3 and freeze-thaw durability testing.
ASTM C406
ASTM C406 is the standard specification for concrete roof tile, with Grade A as the highest grade for durability and strength.
Roofing square
A roofing square equals 100 sq ft of roof area; tile quantity per square depends on the manufacturer's exposure and pieces per square.
Tile weight reference
Concrete roof tile typically weighs 8-12 lb per sq ft and clay tile 6-10 lb per sq ft; always verify the actual product data for structural design.
Step flashing lap
Step flashing uses one piece per tile course, at least 4 in. by 4 in., lapped 2 in. and set under the tile above and over the tile below.
Chimney cricket requirement
A cricket or saddle is required on the up-slope side of a chimney when the chimney width exceeds 30 in., to divert water around it.
Open valley width
An open metal valley is typically at least 24 in. wide, 12 in. on each side, with each course lapped so water flows over the lower piece.
Kick-out flashing
Kick-out flashing at a sidewall diverts water away from the wall and into the gutter; a missing kick-out is a common cause of rot and leaks.
Tile layout centerline
Tile layout starts from a true vertical centerline or a full-tile edge, so cut tiles fall at the rakes and the field stays symmetrical.
Tile exposure
Exposure equals the tile length minus the headlap; the manufacturer's exposure determines pieces per square and the total order quantity.
High-wind tile fastening
In high-wind zones, typically 90 mph basic wind speed or greater, fasten every tile and add fasteners at hips, ridges, and perimeter edges.
Nail penetration into sheathing
Tile nails must penetrate the sheathing at least 3/4 in., and must not be overdriven; leave the head slightly above the tile surface.
Eave closure purpose
A bird stop or eave closure blocks wind-driven rain and prevents birds from entering the open profile at the eave of a tile roof.
Hip and ridge fastening
Hip and ridge tile require at least two fasteners per piece, set over a hip or ridge batten or mortar bed per the manufacturer's instructions.
Closed-cut valley
In a closed-cut valley, tile from one slope crosses the valley and is cut along a line parallel to the valley on the other slope.
Valley underlayment width
Valley underlayment is a membrane or metal at least 24 in. wide, extending at least 12 in. up each slope beneath the tile.
Low-slope tile assembly
Roofs from 2.5:12 to 4:12 require a doubled underlayment or a proprietary waterproofing assembly, detailed per the tile manufacturer.
Batten fastening
Tile battens must be fastened into framing or sheathing per the manufacturer; battens must not rely on sheathing alone for attachment.
Broken tile replacement
To replace a broken tile, lift the tile above, slide the new tile into place, and fasten through the existing nail holes without nailing the tile below.
Leak diagnosis priority
Leak diagnosis starts at flashings, valleys, and penetrations, which cause more leaks than failures in the tile field itself.
Slope factor formula
The slope factor equals the square root of 1 plus the rise over run squared; multiply plan area by the slope factor for actual roof area.
Roof area estimating
Actual roof area equals plan area times the slope factor; add 10-15% waste for hips, valleys, and field cuts when ordering tile.